Replacing the MegaRAID iTBBU02 Battery
CA293-04780
rev 00
page 3 of 10
Procedure
1.
Open the front door of the server rack, locate the DL380 G5 core server at the top of the rack,
and shut down the core server.
2.
Pull down the mounting screw covers on the right and left sides of the rack.
Figure 1: Locating the server mounting screw covers
1
2
1
Right mounting screw cover
2
Left mounting screw cover
3.
If the screws holding the server to the rack are present, remove the screws.
4.
Pull the server out of the rack and into the service position by pulling the mounting screw
covers on both sides.
5.
Disconnect the two power cables from the back of the server.
WARNING:
Do not reconnect the power cables until after you
have replaced the top cover.
6.
Press the server power button to discharge the power supply capacitors.