15
2.
Loosen the captive screws with a Phillips screwdriver to remove the filler panel from the slot.
Keep the removed filler panel for future use.
3.
Insert the SFE-X1 slowly along the slide rails until positioning pins on the backplane are seated
in the positioning holes, and then push the ejector levers inward to lock the SFE-X1 in position.
4.
Use a Phillips screwdriver to fasten the captive screws on the two sides of the SFE-X1.
For the SFE-X1 LED description, see "
MPU and switching fabric module LEDs
Figure 13 Installing an SFE-X1
Installing an LPU
CAUTION:
The RUN LED flashes fast when the FIP is starting up. To avoid hardware damage, do not install or
remove a HIM/MIM during this period.
Slot 3 of the HSR6802/HSR6804 and Slot 7 of the HSR6808 are not provided with filler panels.
Before the installation, make sure the ejector levers of the LPU are outwards.
The procedures for installing LPUs are similar. This section uses a FIP-210 as an example.
To install a FIP-210:
1.
Face the front of the router and locate the slot to be used.