52
===============display clock===============
=================================================
08:54:16 UTC Fri 15/06/2012
===================================================
===============display version===============
===================================================
…
Displaying detailed information about a card
•
Use the
display device verbose
command to display detailed information about all cards.
<Sysname>display device verbose
System-mode(Current/After Reboot): Normal/Normal
Slot No. Board type Status Primary SubSlots
---------------------------------------------------------------------
0 N/A Absent N/A N/A
1 RSE-X2 Normal Master 0
2 N/A Absent N/A N/A
3 N/A Absent N/A N/A
4 FIP-110 Normal N/A 4
5 N/A Absent N/A N/A
Slot 4 : FIP-110(4 Subslots)
Subslot 1 : MIM-4GBE
Subslot 2 : MIM-4GBE
•
Use the
display device slot
slot-number
command to display detailed information about the
card in the specified slot.
<Sysname> display device slot 1
System-mode(Current/After Reboot): Normal/Normal
Slot 1 : RSE-X2
SubSlot No. Card Type Status Max Ports
--------------------------------------------------------
1 Fixed SubCard Normal 3
Table 12 Command output
Field Description
Slot No.
Slot number of the card.
Card Type
Card model. The value
NONE
indicates that no card is present in the slot.
Status
Running status of the card:
•
Absent
—No card is present in the slot.
•
Fault
—The card in the slot is booting, or the card has failed and cannot
boot correctly.
•
Normal
—The card in the slot is operating correctly.
Max Ports
Maximum number of ports that the card supports.