WARNING!
To reduce the risk of personal injury from electrical shock and hot surfaces, disconnect
the power cord from the wall outlet and let the internal system components cool before you touch them.
CAUTION:
When the workstation is plugged in, the power supply has voltage applied to the system
board, even when the workstation is powered off. Failure to disconnect the power cord can result in
damage to the workstation.
Static electricity can damage the electronic components of the workstation or optional equipment. Before
beginning these procedures, be sure that you are discharged of static electricity by briefly touching a
grounded metal object.
1.
Shut down the operating system, power off the workstation and any external devices, and then
disconnect the workstation power cord and external devices from power outlets.
2.
Disconnect the keyboard, monitor, and other external devices that are connected to the
workstation.
3.
Remove the access panel.
CAUTION:
Before pressing the Clear CMOS button, back up the workstation CMOS settings.
Pressing the Clear CMOS button resets CMOS values to factory defaults and erases customized
information, including asset numbers and special settings.
To back up the CMOS settings, run the Computer Setup (F10) Utility and select
Save to
Diskette
from the File menu.
4.
Locate, press, and hold the CMOS button for five seconds.
NOTE:
Verify that the AC power cord is disconnected from the power outlet.
The CMOS button does not clear CMOS if the power cord is connected.
For assistance locating the CMOS button and other components, see
Clearing and Resetting the
CMOS on page 186
.
5.
Replace the access panel.
6.
Reconnect external devices.
7.
Plug in and power on the workstation. The system boots to a F1 prompt and displays a message
that the date/time has changed and that system options have changed.
8.
Press F1. The system shuts down for three seconds and then powers back on.
9.
Use the F10 (Setup) Utility to reset the date and time.
Using the Computer Setup (F10) Utility to Reset CMOS
To reset CMOS using the Computer Setup (F10) Utility:
1.
Access the Computer Setup (F10) Utility menu.
2.
When the Computer Setup message appears in the lower-right corner of the screen, press
F10
,
and then press
Enter
to bypass the title screen, if necessary.
If you do not press
F10
while the message is displayed, the workstation must be restarted to access
this utility.
3.
From the Computer Setup (F10) Utility menu, select
File>Default Setup
.
This restores the settings that include boot sequence order and other factory settings. However, it
does not force hardware rediscovery.
ENWW
Clearing and Resetting the CMOS 187