Connecting the E-MSM466-R
Attaching the grounding wire and antennas
1.
Remove the grounding screw (1) from lug on the E-MSM466-R body
2.
Attach a grounding cable (2), #10 AWG or thicker, with the grounding screw (1).
Figure 10 Grounding cable
1
2
1. Grounding screw
2. Grounding cable
3.
Tighten the grounding screw and ensure the cable is firmly anchored.
4.
Install antennas including antenna connector lightning arresters as described in the respective
Antenna Guide available online (search by antenna part number). An HP Lightning Arrester
(J8996A) Guide is also available online.
Attaching the Ethernet cable
1.
Connect the Ethernet cable to the Ethernet connector (See
“E-MSM466-R key components”
(page 5)
).
2.
Create a drip loop in the Ethernet cable below the E-MSM466-R. A drip loop provides
additional protection against water running down the Ethernet cable and into the connector.
Form the loop as shown here. Make sure that the distance between the loop start and end
points is at least 15 cm (6 inches), and that the cable hangs down at least 25 cm (10 inches).
Figure 11 Drip loop
Connecting the E-MSM466-R