S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
28
Cisco MDS 9000 Family Release Notes for Cisco MDS NX-OS Release 5.2(1)
OL-25090-01
Limitations and Restrictions
Reserved VSAN Range and Isolated VSAN Range Guidelines
On an NPV switch with a trunking configuration on any interface, or on a regular switch where the
feature fport_channel_trunk
command has been issued to enable the Trunking F PortChannels feature,
follow these configuration guidelines for reserved VSANs and the isolated VSAN:
•
If trunk mode is on for any of the interfaces or NP PortChannel is up, the reserved VSANs are 3040
to 4078, and they are not available for user configuration.
•
The Exchange Virtual Fabric Protocol (EVFP) isolated VSAN is 4079, and it is not available for user
configuration.
The following VSAN IDs are assigned in the Fibre Channel Framing and Signaling (FC-FS) interface
standard:
Applying Zone Configurations to VSAN 1
In the setup script, you can configure system default values for the default-zone to be permit or deny,
and you can configure default values for the zone distribution method and for the zone mode.
These default settings are applied when a new VSAN is created. However, the settings will not take effect
on VSAN 1, because it exists prior to running the setup script. Therefore, when you need those settings
for VSAN 1, you must explicitly issue the following commands:
•
zone default-zone permit
vsan 1
•
zoneset distribute full
vsan 1
•
zone mode enhanced
vsan 1
Running Storage Applications on the MSM-18/4
The Cisco MDS 9000 18/4-Port Multiservice Module (MSM-18/4) does not support multiple, concurrent
storage applications. Only one application, such as SME or DMM, can run on the MSM-18/4 at a time.
RSPAN Traffic Not Supported on CTS Ports on 8-Gbps Switching Modules
An inter-switch link (ISL) that is enabled for Cisco TrustSec (CTS) encryption must be brought up in
non-CTS mode to support remote SPAN (RSPAN) traffic on the following modules:
VF_ID Value
Value Description
00h
Do not use as a Virtual Fabric Identifier.
001h ... EFFh
Available as a Virtual Fabric Identifier.
F00h ... FEEh
Reserved.
FEFh
Control VF-ID (see Fibre Channel Link Services
(FC-LS) and Fibre Channel Switch Fabric
Generation 4 (FC-SW-4) standards).
FF0h ... FFEh
Vendor specific.
FFFh
Do not use as a Virtual Fabric Identifier.
FEFh = 4079