Specifications 41
Power specifications
The power requirements for the Apollo a6000 Chassis are met by the following components:
•
HPE 2450W Platinum Hot Plug Redundant Power Supply
•
HPE 2650W Platinum Hot Plug Redundant Power Supply
•
Apollo 6000 Power Shelf
•
AC Input Module
•
Power Management Module
DC power
Specification
Value
Output
12V from power supplies to
system chassis
Minimum (V)
+11.907
Nom (V)
+12.25
Maximum (V)
+12.593
% Reg
+2.8%/-2.8%
Single-phase power
Specification
HPE 2450W Platinum Hot Plug
Redundant Power Supply
HPE 2650W Platinum Hot Plug
Redundant Power Supply
Power cord
IEC-320 C19-C20
2 m (6.5 ft)
IEC-320 C19-C20
2 m (6.5 ft)
Output
2450 W per power supply
2650 W per power supply
Input requirements
Rated input voltage
200 VAC to 240 VAC
200 VAC to 240 VAC
Rated input frequency
50 Hz to 60 Hz
50 Hz to 60 Hz
Rated input current per
power supply (maximum)
13.2 A at 200 VAC
12.7 A at 208 VAC
12.2 A at 220 VAC
14.4 A at 200 VAC
13.8 A at 208 VAC
13.1 A at 220 VAC
Rated input power per
power supply (maximum)
2640 VA
2880 VA
Three-phase power (North America/Japan)
Specification
2450W Platinum Hot Plug
Redundant Power Supply
2650W Platinum Hot Plug
Redundant Power Supply
Power cord
NEMA L15-30p
3.05 m (10 ft)
NEMA L15-30p
3.05 m (10 ft)
Output
2450 W per phase
2650 W per phase
Input requirements
Rated input voltage
200 VAC to 208 VAC line to line
3-phase delta
200 VAC to 208 VAC line to line
3-phase delta
Rated input frequency
50 Hz to 60 Hz
50 Hz to 60 Hz
Maximum input current per
line cord
22.9 A at 200 VAC
22 A at 208 VAC
25 A at 200 VAC
24 A at 208 VAC