AlphaServer ES47/ES80/GS1280 Server Management CLI Reference
2. Run test 13 on all CPUs in the hard partition Default_HP
MBM> test 13
Running test 13, RAID channel Test ... on 2 EV7s
[2003/04/18 15:22:38]
~DIA-W-(pco_04) Test 13 [RAID channel Test] failed on cpu [NS: 0 EW: 0] which i0
[2003/04/18 15:22:38]
BEGIN DIAGNOSTIC TEST FAILURE INFO BEGIN
Test target cabinet:00 drawer:0 CPU0
test number: 13 (hex) [RAID channel Test]
test status: 03
rsvd1: 00
result length: 003e
revision: T1.0-9_ocla
error number: 01 -- Write, Verify Read error
rsvd2: 00
error format: 01
severity code: 01
FRU1: 0
FRU2: 0
FRU3: 0
FRU4: 0
P1: ffff8000.00000000 Expected data (written)
P2: 00000000.00000000 Actual data received (read)
P3: ffff8000.00000000 Failing Address
P4: 00000000.00000000 (null)
P5: 00000000.00000000 (null)
P6: 00000000.00000000 (null)
P7: 00000000.00000000 (null)
P8: 00000000.00000000 (null)
FRU suspect: EV7, Memory
FRU extra: Ev7 not capable of RAID cab:00 drw:0 CPU0
END DIAGNOSTIC TEST FAILURE INFO END
MBM>
See Also
power on, reset, enable test, disable test
3-120
Содержание AlphaServer ES47
Страница 4: ......
Страница 14: ......
Страница 51: ...Commands See Also show partition save partition create partition modify partition 3 27 ...