background image

AlphaServer ES47/ES80/GS1280 Server Management CLI Reference 

0   3   3      1024MB 
0   3   4      1024MB 
0   3   5      1024MB 
0   3   6      1024MB 
0   3   7      1024MB 
 
Total Physical Memory: 32768MB (32.000GB) 
 
MBM> 

2.  Show memory by partitions. 

MBM> sh mem -part 
Hard Partition: HP No.= 0 with total physical memory 8192MB (8.000GB) 
 
   Sub Partition: SP No.=255 with total memory 0MB in  0 chunks: 
 
   Sub Partition: SP No.=  0 with total memory 8192MB in 16 chunks: 
    chunk  0,  size     16MB,  start address 0x00000000,00000000 
    chunk  1,  size   1008MB,  start address 0x00000000,01000000 
    chunk  2,  size     16MB,  start address 0x00000004,00000000 
    chunk  3,  size   1008MB,  start address 0x00000004,01000000 
    chunk  4,  size     16MB,  start address 0x00000008,00000000 
    chunk  5,  size   1008MB,  start address 0x00000008,01000000 
    chunk  6,  size     16MB,  start address 0x0000000c,00000000 
    chunk  7,  size   1008MB,  start address 0x0000000c,01000000 
    chunk  8,  size     16MB,  start address 0x00000020,00000000 
    chunk  9,  size   1008MB,  start address 0x00000020,01000000 
    chunk 10,  size     16MB,  start address 0x00000024,00000000 
    chunk 11,  size   1008MB,  start address 0x00000024,01000000 
    chunk 12,  size     16MB,  start address 0x00000028,00000000 
    chunk 13,  size   1008MB,  start address 0x00000028,01000000 
    chunk 14,  size     16MB,  start address 0x0000002c,00000000 
    chunk 15,  size   1008MB,  start address 0x0000002c,01000000 
 
   Community: No.= 0 with total memory 0MB in  0 chunks: 
 
Hard Partition: HP No.= 1 with total physical memory 0MB (0.000GB) 
 
   Sub Partition: SP No.=255 with total memory 0MB in  0 chunks: 
 
   Sub Partition: SP No.=  0 with total memory 0MB in  0 chunks: 
 
   Community: No.= 0 with total memory 0MB in  0 chunks: 
 
MBM> 

See Also

 

show partition, show system, show duo

 

 

3-100 

Содержание AlphaServer ES47

Страница 1: ...es access to the whole platform at the most fundamental level You can display information such as the system configuration cabling and environmental component status You can update the firmware and power the system or a hard partition on or off as well as halt and reset You can create and delete partitions The CLI also provides one of the two ways you can access the SRM console or operating system...

Страница 2: ...radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at personal expense Class B Equipment This equipment has been tested and found to comply w...

Страница 3: ...nces du Règlement sur le matériel brouilleur du Canada European Union Notice Products with the CE marking comply with the EMC Directive 89 336 EEC and the Low Voltage Directive 73 23 EEC issued by the Commission of the European Community and if this product has telecommunication functionality the R TTE Directive 1999 5 EC Compliance with these directives implies conformity to the following Europea...

Страница 4: ......

Страница 5: ...dressing 2 3 2 4 Conventions 2 4 2 5 Command Names and Qualifiers 2 4 2 6 Editing 2 5 2 7 Online Help 2 6 2 8 MBM Failsafe Loader 2 7 2 8 1 Configuration Booting Images 2 7 2 8 2 Updating Firmware Images 2 8 2 8 3 Getting Help 2 8 2 9 CLI Output Messages 2 9 Chapter 3 Commands 3 1 3 1 Command Summary 3 1 3 2 assign component 3 3 3 3 assign memory 3 5 3 4 bootline 3 7 3 5 build fru 3 8 3 6 clear 3 ...

Страница 6: ...7 3 43 set escape 3 68 3 44 set flow 3 69 3 45 set init 3 70 3 46 set membership 3 71 3 47 set password 3 73 3 48 set sys_serial_num 3 74 3 49 set time 3 75 3 50 shell 3 76 3 51 show 3 77 3 52 show cables 3 78 3 53 show duo 3 80 3 54 show error 3 84 3 55 show fru 3 88 3 56 show grid 3 92 3 57 show log 3 93 3 58 show membership 3 98 3 59 show memory 3 99 3 60 show modem 3 101 3 61 show network 3 10...

Страница 7: ...erator access to it you can use the SPM window to telnet into the Server Management CLI of a particular platform You can do this in three different ways 1 1 1 From the SPM Actions Menu Item Once you have logged in to the SPM as a valid user you can left click on a platform in either the tree view or the right hand view Once you select a platform you can left click on the Actions menu item to telne...

Страница 8: ...CLI Reference 1 1 2 From the SPM Tree View Once you have logged in as a valid SPM user you can directly right click on a platform in the tree view to display a pulldown menu from which you can telnet to the Server Management CLI for that system 1 2 ...

Страница 9: ...agement CLI 1 1 3 From the SPM Platform View From the right pane of the SPM window you can right click on a platform to display a pulldown menu that allows you to telnet to the Server Management CLI of that particular platform 1 3 ...

Страница 10: ... that the AMU is only attached to a single platform at a time 2 Pull down the Actions menu and select Open Telnet from the options available as shown below 1 3 Access the CLI from a PC Telnet session You can access the Server Management CLI from a PC attached to the Corporate LAN or the Multi Server LAN by installing KEAterm or similar software on the PC Instructions for installing this software o...

Страница 11: ...CLI from the MBM Backplane You can attach a serial terminal directly to an MBM backplane to access the Server Management CLI Figure 1 1 shows the serial connector for the MBM backplane on an 8P drawer Figure 1 1 8 P Drawer MBM Backplane Serial Connector 1 5 ...

Страница 12: ...AlphaServer ES47 ES80 GS1280 Server Management CLI Reference Figure 1 2 shows the serial connector for the MBM backplane on a 2P drawer Figure 1 2 2 P Drawer MBM Backplane Connector 1 6 ...

Страница 13: ...Management CLI from the SRM Console If you have accessed the SRM console or operating system for a platform or for a partition or subpartition within a platform you can access the Server Management CLI for the platform by entering the escape sequence Esc Esc MBM 1 7 ...

Страница 14: ......

Страница 15: ...et drawer drawer SBB cabinet 0 7 drawer 0 3 MBM cabinet cabinet drawer drawer MBM cabinet 0 7 drawer 0 3 DUO cabinet cabinet drawer drawer DUOn n 0 3 in the 8P drawer CMM cabinet cabinet drawer drawer CMMn n 0 3 in the 8P drawer CPU cabinet cabinet drawer drawer CPUn n 0 7 in the 8P drawer CPU ew ew_coord ns ns_coord CPU by mesh coordinate ew ns IOP cabinet cabinet drawer drawer IOPn n 0 7 in the ...

Страница 16: ...a minimal set of diagnostics is run Remember this is required for semi hard partitions esc_sequence String 15 chars MBM Modify symbol mbm_escape_string A sequence to go back to MBM halt_on_error String On or off On Modify symbol halt_on_error On any failure in starting a partition halts the startup attempt and returns to the prompt Off the server manager automatically maps out the failing componen...

Страница 17: ...ars to be a separate computer A partition contains CPU memory and I O resources These servers can be Hard partitioned with no routing traffic between CPUs Soft partitioned with routing between all CPUs All memory access is allowed and protection is accomplished through software The server management is responsible for creating configuring testing saving and deleting partitions The partition name i...

Страница 18: ...vertical bars imply combinatorial items a b c indicates that you can choose any combination of a b and c 2 5 Command Names and Qualifiers The server management CLI interface is case insensitive Command names consist of a command verb and in some cases a keyword Each command verb and keyword might have an abbreviation which is determined by the CLI parser For example the minimum match for show syst...

Страница 19: ...ite mode Ctrl B Recall the previous line Ctrl C Abort the command Ctrl D Cancel the current line Ctrl E Move the cursor to the end of the command line Ctrl F Move the cursor to the right within the command line Ctrl H Move the cursor to the beginning of the command line Ctrl R Reprint the command line Ctrl U Clear the command line Other rules include Extra spaces are ignored Everything between the...

Страница 20: ...CLImodem unrecognized command verb crete MBM create prt CLI E tCLImodem unrecognized keyword prt Usage create partition MBM 2 7 Online Help The brief help for each command displays the syntax and a one line description The synopsis line lists all possible options and arguments for the command By default issuing the command help displays a list of supported commands and help lists all commands with...

Страница 21: ... 8 1 Configuration Booting Images From the FSL CLI two commands are available that are not available in the main MBM firmware image Bootline will configure the boot settings of MBM Mbmboot will boot the MBM based on the settings contained in the boot line The bootline menu is shown below FSL bootline clear field go to previous field D quit boot device flash0 processor number 0 host name host file ...

Страница 22: ...loader To get help on a specific command type help cmdname FSL help NAME help FUNCTION Display information about CLI commands SYNOPSIS help command Command synopsis conventions item Implies a placeholder for user specified item item Implies an item or list of items Implies optional keyword or item a b c Implies any one of a b c a b c Implies any combination of a b c The following help topics are a...

Страница 23: ... system MBM Some common CLI output messages are given in the table below Message Possible Cause Common Messages CLI E input too long The command line is longer than 80 characters CLI E unrecognized command verb The first word of the command name is invalid CLI E unrecognized keyword The second word of the command name is invalid CLI E unrecognized qualifiers A command switch qualifier either didn ...

Страница 24: ...nd 0 F for hex CLI E numeric value too large The value is overflow Command Specific Messages CLI E illegal target address CLI E illegal data CLI E deposit data too large for specified type CLI E invalid device name CLI E string too long CLI E string too short 2 10 ...

Страница 25: ...C device disable alert remote test Disable the sending of alerts remote access or a diagnostic test el Event log show the history of CLI inputs and outputs enable alert remote test Enable the modem dial out alert function remote access to the system or a diagnostic test examine or e Read a memory location or CSR IPR or I2 C device halt in out Halt the entire system CPU or partition hangup Terminat...

Страница 26: ...show envar cables duo error fru grid log membership memory modem network partition power sys_serial_num system time version Show specified system information telnet Log in to a remote host test test_num alert led Start a diagnostic test or test the modem setup or cable LEDs update Update the firmware uptime Show the amount of time since initialization of all or specified MBMs and PBMs 3 2 ...

Страница 27: ...rawer and ranges from 0 to 7 IOP n The IOP by cabinet and drawer number n refers to the IOP of the 8P drawer and ranges from 0 to 7 A user can assign the IOP only to a subpartition SBB The SBB by cabinet and drawer number hp hard_partition Hard partition name sp sub_partition Subpartition name Assign to subpartition 0 if no subpartition name is given Options cabinet cabinet Cabinet number in hex I...

Страница 28: ...ove IOP1 from a different hard partition resulting in an error MBM assign comp ca 0 dr 3 cpu1 hp account_dept sp acct_usa CLI E tCLImodem cannot move IOP across different HP MBM 2003 04 11 10 21 36 PCO W pco 01 Command handler rtn failed for Id 5622 cmd 41a See Also show partition show system create partition assign memory 3 4 ...

Страница 29: ...on sp sub_partition com Arguments memory_size The memory size in units of GB or MB must be multiples of 8MB hp hard_partition Hard partition name sp sub_partition Subpartition name com Assign the memory to community memory accessible to all subpartition within the hard partition Options None Examples 1 Assign 16GB of memory to the subpartition acct_usa MBM assign mem 16GB hp account_dept sp acct_u...

Страница 30: ...AlphaServer ES47 ES80 GS1280 Server Management CLI Reference See Also show partition create partition assign component 3 6 ...

Страница 31: ... bootline Arguments None Options None Example Change the method of booting to boot from the network by modifying the boot device to be fei and inet on Ethernet to be 10 0 0 1 Make sure that the host inet IP address matches the TFTP server interface IP FSL bootline clear field go to previous field D quit boot device flash0 fei processor number 0 host name host file name vxWorks inet on ethernet e 1...

Страница 32: ...y ASCII 0 7 D Duo number represented by ASCII hex 0 F within the cabinet It is calculated by Drawer_num 4 Duo_num For example 9 means drawer 2 duo 1 Drawer number ranges 0 3 So is Duo number within the drawer R RIMM slot in Duo ASCII 0 9 for CPU 0 RIMM 0 9 ASCII A J for CPU1 RIMM 0 9 I Insertion count ASCII 0 9 then A Z Firmware can t directly detect the RIMM insertion A counter keeps track of how...

Страница 33: ...s not apply to third party FRUs offset The beginning byte offset inhex within this FRU s EEPROM where the following data bytes are written byte Up to 16 data bytes to be written At least one byte must be supplied after the offset Options cabinet cabinet Cabinet number in hex If not specified defaults to 0 drawer drawer Drawer number in hex If not specified defaults to 0 duo duo Dual CPU module num...

Страница 34: ...B0 DRW0 DUO0 RIMM30 40 20 1C872 01 CE CAB0 DRW0 DUO0 RIMM50 40 20 1C872 01 CE CAB0 DRW0 DUO0 RIMM60 40 20 1C872 01 CE CAB0 DRW0 DUO0 RIMM70 40 20 1C872 01 CE CAB0 DRW0 DUO0 RIMM80 40 20 1C872 01 CE CAB0 DRW0 DUO0 RIMM01 40 20 1C872 01 CE CAB0 DRW0 DUO0 RIMM11 40 20 1C872 01 CE CAB0 DRW0 DUO0 RIMM21 40 20 1C872 01 CE CAB0 DRW0 DUO0 RIMM31 40 20 1C872 01 CE CAB0 DRW0 DUO0 RIMM51 40 20 1C872 01 CE CA...

Страница 35: ...P00FL CE CAB0 DRW0 DUO0 RIMM61 06 20 1C872 01 GS1280 32P00GL CE CAB0 DRW0 DUO0 RIMM71 06 20 1C872 01 GS1280 32P00HL CE CAB0 DRW0 DUO0 RIMM81 06 20 1C872 01 GS1280 32P00IL CE CAB0 DRW0 DUO0 VRM0 CPU 00 nightlyFri_4 Fri_47 7F7FF8 CAB0 DRW0 DUO0 VRM1 CPU 00 nightlyFri_5 Fri_48 7F7FF8 CAB0 DRW0 DUO0 VRM2 CPU 00 nightlyFri_6 Fri_49 7F7FF8 CAB0 DRW0 DUO0 VRM3 CPU 00 nightlyFri_7 Fri_50 7F7FF8 CAB0 DRW0 ...

Страница 36: ...ble and restores the default value if there is one Syntax clear smv Arguments smv The server management environment variable Wildcard for all server management environment variables Options None Example Restore the default setting of the environment variable auto_connect_srm MBM clear srm_auto_connect MBM See Also show set 3 12 ...

Страница 37: ...continues to occur but nothing will be sent over the modem Also the most recent alert is logged as the alert type If the system is in secure mode via the Operator Control Panel keyswitch the sending of alerts is still allowed even through remote access into the system is not Syntax clear alert Arguments None Options None Examples This command removes any pending interrupts and allows the capturing...

Страница 38: ...S1280 Server Management CLI Reference 3 8 clear display Erases the current display screen on the console terminal Syntax clear display Arguments None Options None Example Clear the terminal display MBM clear display MBM 3 14 ...

Страница 39: ...dule CMM CMM module VRMn CPU VRM n 0 5 for CPUs VRMn RIMM VRM n 0 4 for RIMMs VRM0 TERM VRM for terminator RIMMnc RIMMs n 0 9 for slot number c 0 1 for CPU processor number PSn PCI power supply n 0 1 PWRn Power supply tray n 0 1 of SBB PWRn PSp Power supply of SBB CLM Common Logic Module only exists with Superdome Power Supply subsystem DUO CMM VRM and RIMM require the additional qualifier duo to ...

Страница 40: ...hecksum error between bytes 128 254 CAB0 DRW1 PCI 70 FRU Checksum error between bytes 0 62 FRU Checksum error between bytes 64 126 FRU Checksum error between bytes 128 254 CAB0 DRW1 IOR0 70 FRU Checksum error between bytes 0 62 FRU Checksum error between bytes 64 126 FRU Checksum error between bytes 128 254 MBM clear error ca 0 COCP MBM clear error ca 0 dr 0 DOCP MBM clear error ca 0 dr 1 IOR0 MBM...

Страница 41: ...og ca 0 dr 0 Error log from MBM in Cabinet 0 Drawer 0 CLI E tCLImodem error log is empty MBM 2 Clear the error logs of all micros MBM clear log all Clearing error log of MBM in Cabinet 0 Drawer 0 Clearing error log of MBM in Cabinet 0 Drawer 1 Clearing error log of MBM in Cabinet 0 Drawer 2 Clearing error log of MBM in Cabinet 0 Drawer 3 Clearing error log of PBM in Cabinet 1 Drawer 1 Clearing err...

Страница 42: ...0 GS1280 Server Management CLI Reference 3 11 clear port Clears the serial port Syntax clear port Arguments None Options None Example Reset the server management CLI port MBM clear port MBM See Also set baud set flow 3 18 ...

Страница 43: ...for the hard partition named sp subpartition Clear the SRM environment variables for the soft partition named Clear all subparitions within the hard partition if no explicit subpartition is given all Clear the SRM environment variables for all partitions Examples 1 Clear the SRM environment variables for all subpartitions within a given hard partition MBM clear srmenv hp hp0 MBM 2 Clear the SRM en...

Страница 44: ... 8P in hex d2 dest_drawer Drawer number of the destination 8P or PCI drawer in hex source_port Either the IP port or IOP IP port is denoted by N02 N46 S13 S57 E67 W01 IOP is denoted by IOP n dest_port Either the IP port or PCI IOR IP port is denoted by N02 N46 S13 S57 E67 W01 PCI IOR is denoted by IOR n Options led on off The options on or off turn the LEDs on or off By default the LEDs are on Exa...

Страница 45: ... the matching destination cable according to the mess configuration The LEDs of both ports are lit MBM config cables c1 0 d1 1 S13 Turn on LEDs by default MBM 4 Configure the cable between IOP3 of 8P drawer 0 on cabinet 1 and IOR0 of PCI drawer 3 on cabinet 4 MBM config cables c1 1 d1 0 IOP3 c2 4 d2 3 IOR0 MBM See Also show cables test led 3 21 ...

Страница 46: ...ubpartition in a given hard partition Each session has the MBM s or PBM s IP address and a unique port number The SM environment variable srm auto_connect will control the auto connect feature If it is set to be on connect is issued automatically upon resetting or powering on a non partitioned system Also the current implementation of the connect command only handles communicating with the SRM on ...

Страница 47: ...e escape sequence MBM connect hp account_dept sp acct_usa P00 Connecting to partition Use the sequence MBM to return P00 P00 MBM MBM 3 Connect to the only subpartition within the hard partition hr_dept MBM connect hp hr_dept Connecting to partition Use the sequence MBM to return P00 See Also hangup 3 23 ...

Страница 48: ...d and its components go to the Global Free_Pool Syntax create partition hp hard_partition max_CPUs sub_partition_type stripe hp hard_partition sp sub_partition Arguments hp hard_partition Hard partition name The name is limited to 19 characters alphanumeric and underscore only and it cannot be Default_HP or Free_Pool sp sub_partition Subpartition name The name is limited to 19 characters alphanume...

Страница 49: ...Commands MBM create partition hp account_dept sp acct_usa MBM See Also show partition modify partition delete partition assign component assign memory 3 25 ...

Страница 50: ...artition hp hard_partition sp sub_partition all Arguments hp hard_partition Hard partition name sp sub_partition Subpartition name The hard partition and all of its subpartitions are deleted if no explicit subpartition is given all All partitions Options None Examples 1 Delete the subpartition asia_branch of hard partition account_dept MBM delete partition hp account_dept sp asia_branch MBM 2 Atte...

Страница 51: ...Commands See Also show partition save partition create partition modify partition 3 27 ...

Страница 52: ...a quadword transaction This is the default deposit size and also the default for GPR and IPR accesses n count The number of subsequent locations specified in hex The address is incremented by the address size qualifier each time The default is 0 This is not a sticky qualifier ipr Specifies a CPU IPR pmem Specifies the physical memory space of a device such as MBM PBM CMM and CPU io Specifies the I...

Страница 53: ...dr 3 pbm iic 1 0 50 0 7 3 Write to the MBM memory space MBM e ca 0 dr 2 mbm 20 n 3 pmem examine MBM memory space 0 2 mbm pmem 20 FC 0 2 mbm pmem 21 D3 0 2 mbm pmem 22 20 0 2 mbm pmem 23 00 MBM deposit e0 n 3 write to MBM memory space MBM e n 3 0 2 mbm pmem 20 E0 0 2 mbm pmem 21 E0 0 2 mbm pmem 22 E0 0 2 mbm pmem 23 E0 MBM See Also examine e 3 29 ...

Страница 54: ... server management from issuing alerts to other platforms Getting the remote operator s attention is essential to insure the environmental conditions do not damage the hardware Syntax disable alert Arguments None Options None Example Turn off the modem dial out MBM disable alert not yet implemnted Disabling alert dial out MBM See Also enable alert clear alert test alert show modem 3 30 ...

Страница 55: ...preventing users from dialing in remotely Syntax disable remote Arguments None Options None Example Do not allow the remote user to log in MBM disable remote not yet implemented Disabling remote dial in MBM See Also enable remote set init show modem 3 31 ...

Страница 56: ...g for debug purpses Syntax disable test test_number Argument test_number The number assigned to a diagnostic test in hex Options None Example Disable XSROM test 12 which is Data Pattern March read write MBM show diag_mask diag_mask FFFFFFFFFFFFFFFFFFFFFFFF MBM disable test 12 MBM show diag_mask diag_mask FFFFFFFFFFFFFFFFFFFBFFFF See Also enable test show 3 32 ...

Страница 57: ... pco_03 Preparing to power on partition HP HP1 2003 04 10 03 13 54 PCO I pco_02 Running diagnostics on HP HP0 2003 04 10 03 13 58 PCO I pco_03 Running diagnostics on HP HP1 2003 04 10 03 14 38 PCO I pco_02 Diagnostics completed on HP HP0 2003 04 10 03 14 38 PCO I pco_02 HP HP0 SP Default_SP Primary is NS 0 EW 0 which is cab 00 drw 0 cpu 0 2003 04 10 03 14 39 PCO I pco_02 Loading SRM on Primary for...

Страница 58: ...ver an alert condition occurs An alert is sent every 30 minutes until either alerts are disabled or the alert is cleared Syntax enable alert Arguments None Options None Example Turn on the modem dial out MBM enable alert not yet implemented Enabling alert dial out MBM See Also disable alert clear alert test alert show modem set alert set dial 3 34 ...

Страница 59: ...ions None Example Enable remote access to the system MBM enable remote not yet implemented Enabling remote dial in MBM See Also disable remote set init show modem 3 24enable test Turns on a diagnostic test 3 24 1 1 Syntax enable test test_number 3 24 1 2 Argument test_number A diagnostic test number in hex 3 24 1 3 Options None 3 24 1 4 Example 3 35 ...

Страница 60: ...ference Enable XSROM test 12 which is Data Pattern March read write MBM set diag_min_flag on MBM show diag_mask diag_mask 000000010003000300030000 MBM enable test 12 MBM show diag_mask diag_mask 000000010003000300070000 MBM See Also disable test show 3 36 ...

Страница 61: ... Perform a longword transaction q Perform a quadword transaction This is the default for GPR and IPR accesses n count The number of subsequent locations in hex The address is incremented by the address size qualifier each time The default is 0 ipr Specifies a CPU IPR pmem Specifies the physical memory space of a device such as MBM PBM CMM or CPU io Specifies the IO space of a micro such as MBM PBM...

Страница 62: ...ic 1 0 50 27 b 0 3 mbm iic 1 0 50 27 19 MBM 3 Read from and write to the MBM memory space MBM e ca 0 dr 2 mbm 20 n 2 pmem examine MBM memory space 0 2 mbm pmem 20 F4 0 2 mbm pmem 21 FB 0 2 mbm pmem 22 20 MBM d e0 n 2 write to MBM memory space MBM e n 2 0 2 mbm pmem 20 E0 0 2 mbm pmem 21 E0 0 2 mbm pmem 22 E0 MBM 4 Read from and write to the MBM memory space MBM e sym dumppkt_enable 28ccf8 dumppkt_...

Страница 63: ...ied the number defaults to 0 drawer drawer Drawer number in hex If not specified the number defaults to 0 ew ew_coord East West coordinate of the CPU in hex ns ns_coord North South coordinate of the CPU in hex hp hard_partition Hard partition name sp sub_partition Subpartition name All subpartitions under the hard partition are affected if none is specified all All partitions Examples 1 Assert sys...

Страница 64: ...Reference 4 Halt all partitions MBM halt in all MBM 5 Halt an individual CPU by its physical location cabinet and drawer MBM halt in ca 0 dr 2 CPU0 MBM 6 Halt an individual CPU by its mesh coordinate MBM halt in ew 1 ns 0 CPU0 MBM See Also halt out 3 40 ...

Страница 65: ...ptions cabinet cabinet Cabinet number in hex If not specified the number defaults to 0 drawer drawer Drawer number in hex If not specified the number defaults to 0 ew ew_coord East West coordinate of the CPU in hex ns ns_coord North South coordinate of the CPU in hex hp hard_partition Hard partition name sp sub_partition Subpartition name All subpartitions under the hard partition are affected if ...

Страница 66: ...ssert halt to all partitions MBM halt out all MBM 5 Deassert halt to an individual CPU by physical location cabinet and drawer MBM halt out ca 0 dr 2 CPU0 MBM 6 Deassert halt to an individual CPU by mesh coordinate MBM halt out ew 1 ns 0 CPU0 MBM See Also halt in 3 42 ...

Страница 67: ...if there is only one subpartition within the given hard partition MBM The micro MBM PBM The micro PBM port The port number that the MBM PBM is connected to Port 23 is for CLI and port 322 for Vxworks shell Options cabinet cabinet Cabinet number in hex Defaults to 0 if not specified drawer drawer Drawer number in hex Defaults to 0 if not specified Examples 1 Terminate the console connection MBM han...

Страница 68: ... a b c a b c Implies any combination of a b c The following help topics are available assign component assign memory bootline build fru clear clear alert clear display clear error clear log clear port clear srmenv config cables connect create partition d delete partition deposit disable alert disable remote disable test e el enable alert enable remote enable test examine halt in halt out hangup he...

Страница 69: ...Commands 2 Help on a particular command The characters in square brackets are optional MBM help show cable NAME sh ow cab le FUNCTION Display the cable configuration SYNOPSIS show cable ip io MBM 3 45 ...

Страница 70: ...tions None Examples Initialize the modem and allow remote access to the system if the initialization succeeds 1 A modem is present and the initialization completes MBM init modem not yet implemented Initializing modem passed Modem initialized MBM 2 The initialization fails MBM init modem not yet implemented Error during Modem Initialization MBM See Also set init show modem 3 46 ...

Страница 71: ...binet and drawer number DUO n The dynamic duo by cabinet and drawer number The value of n refers to the dynamic duo within the 8P drawer and ranges from 0 to 3 PWR n SBB power interface module The value n is 0 for 48 V power supply n may change for future power supply types Options cabinet cabinet Cabinet number in hex The cabinet number is required to identify the component and defaults to 0 if n...

Страница 72: ... or PBM If a remote login is active via telnet it is stopped Syntax logout Arguments None Options None Example Telnet to a remote MBM with IP address 10 254 1 0 and then log out from it MBM telnet 10 254 1 0 Connecting to 10 254 1 0 Exit sequence is MBM Welcome GS1280 Server Manager X2 2 144 MBM logout Closed connection MBM See Also telnet 3 48 ...

Страница 73: ... main MBM image FSL mbmboot boot device flash unit number 0 processor number 0 host name host file name vxWorks inet on ethernet e 10 250 250 250 host inet h 10 253 0 254 user u target flags f 0xa0 other o fei 06 07 08 09 Attaching interface lo0 done Adding 5254 symbols for standalone VxWorks Copyright 1984 1998 Wind River Systems Inc CPU AMD SC520 CDP VxWorks 5 4 2 BSP version 1 2 0 Creation date...

Страница 74: ...eference Marver Server Management X1 0 11202 Starting up Image built on Apr 16 2002 at 12 52 30 Running POST 0A 0B 0C 0D 0E Cabinet number 0 Drawer number 3 Micro type 0 Node IP address 10 3 0 1 probeQ 2ad934 grpTask i RcvQ 2ad934 See Also bootline 3 50 ...

Страница 75: ... off Arguments hp hard_partition Hard partition name CPU max_CPUs The maximum number of CPUs that can ever be placed in the hard partition This value is used to determine the proper routing and memory algorithm stripe on off Turn on or turn off memory striping Options None Example 1 Modify hard partition of account_dept by allowing more CPUs MBM modify partition hp account_dept cpu 64 MBM See Also...

Страница 76: ...3 for the Expanded I O drawer PCI The PCI drawer by cabinet and drawer number SBB The entire system building block Options cabinet cabinet Cabinet number in hex If not specified the number defaults to 0 drawer drawer Drawer number in hex If not specified the number defaults to 0 hp hard_partition Hard partition name all All partitions Examples 1 Power off a system with only one hard partition This...

Страница 77: ...3 04 10 03 09 44 PCO I pco_00 Preparing to power off partition HP HP1 2003 04 10 03 09 44 PCO I pco_03 Preparing to power off partition HP HP2 2003 04 10 03 09 45 PCO I pco_01 Preparing to power off partition HP HP3 MBM 5 Power off dual processor module 3 in drawer 2 of cabinet 0 MBM power off ca 0 dr 2 duo3 MBM 6 Power off 8P drawer 2 of cabinet 0 MBM power off ca 0 dr 2 sbb MBM 7 Power off PCI d...

Страница 78: ...nects to the console session conn hp RedSox sp Pedro the powerup messages the grid and diagnostics will be displayed All of the sub partition console buffers will contain the grid and diagnostics power up messages Any diagnostic failures from any hard partition are delivered to the MBM session for high visibility They also are sent to the console session Use the show power command to confirm the p...

Страница 79: ... Clocks on 4 EV7s Running test 21 IO7 Data Path Scratch CSR on 4 EV7s Running test 22 IO Single Bit Error checkers on 4 EV7s Running test 23 IO Double Bit Error checkers on 4 EV7s Running test 24 IO Timer Expirations on 4 EV7s Running test 25 IO up hose SBE checkers on 4 EV7s Running test 26 IO up hose DBE checkers on 4 EV7s Running test 27 IO7 pass2 data mover test on 4 EV7s Running test 30 Confi...

Страница 80: ...ion all xsrom MBM 3 Power on hard partition account_dept in a multiple partitioned system MBM power on hp account_dept 2003 04 16 00 14 56 PCO I pco_02 Preparing to power on partition HP account_dept 2003 04 16 00 15 15 PCO I pco_02 Running diagnostics on HP account_dept 2003 04 16 00 15 31 DIA W pco_02 Test 17 T12 with isolation info MFG failed on cpu NS 0 EW 1 which is cab 00 drw 0 cpu 2 2003 04...

Страница 81: ...eturn PCO I pco_01 Preparing to power on partition HP hp0 PCO I pco_01 Configuring for 8 CPUs for HP 0 hp0 0 1 2 3 4 5 6 7 8 9 A B C D E F 0 wP P P Pw P Processor F Filler 1 wP P P Pw connection connection 2 W E N 0 0 3 S v ns ew 4 5 6 7 0 1 2 3 4 5 6 7 8 9 A B C D E F PCO I pco_01 Running diagnostics on HP hp0 Running test 10 Initialize RAMBUS on 8 EV7s Running test 11 Initialize Memory on 8 EV7s...

Страница 82: ...AlphaServer ES47 ES80 GS1280 Server Management CLI Reference 8 Power on PCI drawer 2 of cabinet 1 MBM power on ca 1 dr 2 pci MBM See Also power off show power reset connect 3 58 ...

Страница 83: ... to the CLI session for high visibility They also are sent to the console session NOTE Subpartitions cannot be reset individually Syntax reset cabinet cabinet drawer drawer CPU n ew ew_coord ns ns_coord CPU hp hard_partition all xsrom micro cabinet cabinet drawer drawer micro all Arguments CPU n The CPU by cabinet and drawer number n refers to the CPU number within the 8P drawer and ranges from 0 ...

Страница 84: ...r checkers on 4 EV7s Running test 23 IO Double Bit Error checkers on 4 EV7s Running test 24 IO Timer Expirations on 4 EV7s Running test 25 IO up hose SBE checkers on 4 EV7s Running test 26 IO up hose DBE checkers on 4 EV7s Running test 27 IO7 pass2 data mover test on 4 EV7s Running test 30 Configure RBOX Routes on 22 EV7s Running test 31 Clear Errors Enable Routes on 22 EV7s Running test 32 Route ...

Страница 85: ... 2003 04 16 00 14 56 PCO I pco_02 Preparing to reset partition HP account_dept 2003 04 16 00 15 15 PCO I pco_02 Running diagnostics on HP account_dept 2003 04 16 00 16 21 PCO I pco_02 Diagnostics completed on HP account_dept 2003 04 16 00 16 21 PCO I pco_02 HP account_dept SP Default_SP Primary is NS 0 EW 0 which is cab 00 drw 0 cpu 0 2003 04 16 00 16 21 PCO I pco_02 Loading SRM on Primary for HP ...

Страница 86: ...O I pco_01 Preparing to reset partition HP hp0 PCO I pco_01 Configuring for 8 CPUs for HP 0 hp0 more progress messages P00 5 Reset CPU 3 in drawer 2 of cabinet 0 MBM reset ca 0 dr 2 cpu3 MBM 6 Reset the CPU with mesh coordinate 2 3 MBM reset ew 2 ns 3 cpu MBM 7 Reset micro CMM 0 of drawer 2 in cabinet 0 MBM reset ca 0 dr 2 cmm0 micro MBM 8 Reset all micros MBM reset micro all Resetting all micros ...

Страница 87: ...tition must be saved a particular subpartition cannot Syntax save partition hp hard_partition all Arguments None Options hp hard_partition Hard partition name all All partitions Examples 1 Save all subpartitions under the hard partition account_dept MBM save partition hp account_dept MBM 2 Save all partitions MBM save partition or MBM save partition all MBM See Also show partition create partition...

Страница 88: ...ble type is integer specify values in hex Note See the section on environment variables for details Syntax set smv value Arguments smv Variable name Names are case insensitive and can consist of a maximum of 32 characters including NULL value The value assigned to the variable If the variable is of type integer specify values in hex Options None Example Set the feature that automatically connects ...

Страница 89: ...g The ASCII string that is sent to the modem when an alert condition is triggered It is sent after the dial string is sent Issuing the set alert command without an alert string causes the current alert string to be erased Options None Example Set up the alert string MBM set alert 15085551212 MBM00 Note The and characters are required to terminate the alert string Without them the alert may not be ...

Страница 90: ...d rate of the modem port The baud rate is nonvolatile Syntax set baud baud_rate or set modem_baud baud_rate Argument baud_rate The baud rate for the specified channel one of 2400 3600 4800 7200 9600 19200 38400 and 57600 Options None Example Set the baud rate of the modem port to 38 4k MBM set baud 38400 MBM See Also clear port set flow show modem 3 66 ...

Страница 91: ...before the alert string Because modem commands disallow mixed cases all alphabetic characters in the dial string are converted to uppercase Syntax set dial dial_string Argument dial_string The ASCII string that is sent to the modem when an alert condition is triggered If no argument is given the dial string is erased Options None Example Set up the dial string to call a numeric paging service MBM ...

Страница 92: ...s stored in the MBM s or PBM s EEPROM The default escape sequence is SPMU The escape key on a PC keyboard is equivalent to control left bracket Either esc or is acceptable Use the show modem command to confirm the escape sequence before exiting the server management CLI Syntax set escape esc_sequence Argument esc_sequence The escape sequence for entering the server management CLI The default escap...

Страница 93: ...ol or set modem_flow flow_control Where modem_flow is a server management environment variable Argument flow_control The supported flow control types for the modem port none software hardware or both Options None Example Set the flow control of the modem port MBM set flow hardware MBM See Also set baud clear port show modem 3 69 ...

Страница 94: ...g are converted to uppercase It also automatically configures the modem s flow control according to the flow control setting and enables the modem carrier detect features to monitor the modem connectivity Syntax set init init_string Argument init_string The ASCII string that is sent to the modem when the system management CLI attempts to initialize it for remote access and sending of alerts The in...

Страница 95: ...et Cabinet number in hex Cabinet number is required to identify the component and defaults to 0 if it s not specified drawer drawer Drawer number in hex Drawer number is required to identify the component and defaults to 0 if it s not specified subtract Subtract a micro from the list of micros This option requires the cabinet drawer and a micro argument the micro must be in the list of micros in o...

Страница 96: ...GRP I interrupt GROUP IS STABLE ID 100010a a 2003 04 17 15 49 13 REC W trecTask Server management group is stable GRP W grp_Probe MBM PBM cab 00 drw 2 is not in the member list GRP W grp_Probe Use Set Membership add ca 0 dr 2 PBM MBM 3 Example of the auto option also the default if nothing is specified MBM Set Membership auto GRP E grp_IAmAlive MISSING NEIGHBOR timeout from Cab 0 Drawer 5 Cab Drw ...

Страница 97: ...sword is mvfirmware The password is nonvolatile and stored in the EEPROM of the MBM or PBM Syntax set password password Argument password The password that must be entered by a remote session to gain access to the system Options None Example Change the remote access password MBM set password mvfw MBM See Also show modem 3 73 ...

Страница 98: ...agates the serial number to all EEPROMs except RIMMs Syntax set sys_serial_num serial_number Argument serial_number The system serial number limited to 12 characters Options None Example Set the system serial number MBM sh sys_serial sys_serial_num is not set MBM set sys_serial_num marvel_fw16P Updating SYS_SERIAL_NUM in FRU EEPROMs MBM MBM sh sys_serial sys_serial_num MARVEL_FW16P MBM See Also sh...

Страница 99: ...r changes Warning Changing the base time will affect the time on all existing partitions Syntax set time date time Arguments date The format is yyyy mm dd time The format is hh mm ss Options None Examples 1 Change the date and time MBM set time 2002 04 16 17 20 30 MBM show time Common base time 2002 04 16 17 20 34 HP Name SP Name Delta Time Days hh mm ss hp0 Default_SP 00 00 00 00 hp1 Default_SP 0...

Страница 100: ...e 3 50 shell Starts a vxworks shell Note This command will be removed when the MBM PBM firmware is not shipped with the vxworks shell Syntax shell Arguments None Options None Example Spawn a new shell task to go back to the shell prompt MBM shell 10 0 0 1 3 76 ...

Страница 101: ...es are displayed in hex Syntax show smv Arguments smv The environment variable name Lists all environment variables if no variable name is provided List all environment variables Options None Example Display a particular variable value MBM show srm_auto_connect MBM srm_auto_connect 1 See Also set clear 3 77 ...

Страница 102: ...cates a wrap around X means wrong connection and x means expected but missing connection means unknown cable status For IO cables dashes indicate a connection between the IOR and the IO port of the CPU Otherwise there is no connection There are four IORs per Expanded I O shelf otherwise there is only one IOR per standard PCI drawer Syntax show cables ip io Arguments None Options ip Show only the I...

Страница 103: ...Commands IO cabling between IORs of the PCI drawer and CPU IOPs PCI drawer SBB Cab Drw IOR Cab Drw IOP 1 1 0 0 0 0 1 2 0 0 3 0 1 3 0 0 1 0 1 4 0 0 2 2 MBM See Also config cables 3 79 ...

Страница 104: ...own drawer drawer Drawer number in hex If this qualifier is not used all drawers are shown Example 1 Show all dual CPU modules in the system MBM sh duo DUO0 is in Cabinet 0 Drawer 0 Slot 0 CMM Status OK CMM Power state ON CPU0 CPU1 CPU State SRM XSROM CPU Diag status TBD TBD CPU Memory 1024MB exclude RAID 1024MB exclude RAID RIMM0 128MB 128MB RIMM1 128MB 128MB RIMM2 128MB 128MB RIMM3 128MB 128MB R...

Страница 105: ...Non existent 0MB Non existent CPU Revision EV7 2 1 EV7 2 1 CPU Cache 1 5 MB 1 5 MB CPU Speed 1000 MHz 1000 MHz DUO3 is in Cabinet 0 Drawer 0 Slot 3 CMM Status OK CMM Power state ON CPU6 CPU7 CPU State XSROM XSROM CPU Diag status TBD TBD CPU Memory 1024MB exclude RAID 1024MB exclude RAID RIMM0 128MB 128MB RIMM1 128MB 128MB RIMM2 128MB 128MB RIMM3 128MB 128MB RIMM4 0MB Non existent 0MB Non existent ...

Страница 106: ...B 1 5 MB CPU Speed 1000 MHz 1000 MHz DUO2 is in Cabinet 0 Drawer 1 Slot 2 CMM Status OK CMM Power state ON CPU4 CPU5 CPU State XSROM XSROM CPU Diag status TBD TBD CPU Memory 1024MB exclude RAID 1024MB exclude RAID RIMM0 128MB 128MB RIMM1 128MB 128MB RIMM2 128MB 128MB RIMM3 128MB 128MB RIMM4 0MB Non existent 0MB Non existent RIMM5 128MB 128MB RIMM6 128MB 128MB RIMM7 128MB 128MB RIMM8 128MB 128MB RI...

Страница 107: ... ON CPU4 CPU5 CPU State SRM XSROM CPU Diag status TBD TBD CPU Memory 1024MB exclude RAID 1024MB exclude RAID RIMM0 128MB 128MB RIMM1 128MB 128MB RIMM2 128MB 128MB RIMM3 128MB 128MB RIMM4 128MB 128MB RIMM5 128MB 128MB RIMM6 128MB 128MB RIMM7 128MB 128MB RIMM8 128MB 128MB RIMM9 128MB 128MB CPU Revision EV7 2 1 EV7 2 1 CPU Cache 1 5 MB 1 5 MB CPU Speed 1000 Mhz 1000 Mhz MBM See Also show system show ...

Страница 108: ...B0 DRW0 DUO0 RIMM21 40 FRU checksum error between bytes 128 254 CAB0 DRW0 DUO0 RIMM31 40 FRU checksum error between bytes 128 254 CAB0 DRW0 DUO0 RIMM51 40 FRU checksum error between bytes 128 254 CAB0 DRW0 DUO0 RIMM61 40 FRU checksum error between bytes 128 254 CAB0 DRW0 DUO0 RIMM71 40 FRU checksum error between bytes 128 254 CAB0 DRW0 DUO0 RIMM81 40 FRU checksum error between bytes 128 254 CAB0 D...

Страница 109: ...254 CAB0 DRW1 DUO1 RIMM61 40 FRU checksum error between bytes 128 254 CAB0 DRW1 DUO1 RIMM71 40 FRU checksum error between bytes 128 254 CAB0 DRW1 DUO1 RIMM81 40 FRU checksum error between bytes 128 254 CAB0 DRW2 DUO0 CMM 10 FRU checksum error between bytes 0 62 CAB0 DRW2 DUO0 RIMM00 40 FRU checksum error between bytes 128 254 CAB0 DRW2 DUO0 RIMM10 40 FRU checksum error between bytes 128 254 CAB0 D...

Страница 110: ...IMM01 40 FRU checksum error between bytes 128 254 CAB0 DRW3 DUO1 RIMM11 40 FRU checksum error between bytes 128 254 CAB0 DRW3 DUO1 RIMM21 40 FRU checksum error between bytes 128 254 CAB0 DRW3 DUO1 RIMM31 40 FRU checksum error between bytes 128 254 CAB0 DRW3 DUO1 RIMM51 40 FRU checksum error between bytes 128 254 CAB0 DRW3 DUO1 RIMM61 40 FRU checksum error between bytes 128 254 CAB0 DRW3 DUO1 RIMM7...

Страница 111: ... bytes 128 254 CAB0 DRW1 DUO0 RIMM61 40 FRU checksum error between bytes 128 254 CAB0 DRW1 DUO0 RIMM71 40 FRU checksum error between bytes 128 254 CAB0 DRW1 DUO0 RIMM81 40 FRU checksum error between bytes 128 254 CAB0 DRW1 DUO0 RIMM91 40 FRU checksum error between bytes 128 254 MBM See Also clear error build fru show fru 3 87 ...

Страница 112: ...CAB0 DRW0 DUO0 RIMM20 06 20 1C872 01 GS1280 32P002L CE CAB0 DRW0 DUO0 RIMM30 06 20 1C872 01 GS1280 32P003L CE CAB0 DRW0 DUO0 RIMM50 06 20 1C872 01 GS1280 32P005L CE CAB0 DRW0 DUO0 RIMM60 06 20 1C872 01 GS1280 32P006L CE CAB0 DRW0 DUO0 RIMM70 06 20 1C872 01 GS1280 32P007L CE CAB0 DRW0 DUO0 RIMM80 06 20 1C872 01 GS1280 32P008L CE CAB0 DRW0 DUO0 RIMM01 06 20 1C872 01 GS1280 32P00AL CE CAB0 DRW0 DUO0 ...

Страница 113: ...RW1 DUO0 RIMM00 06 20 1C872 01 GS1280 32P040L CE CAB0 DRW1 DUO0 RIMM10 06 20 1C872 01 GS1280 32P041L CE CAB0 DRW1 DUO0 RIMM20 06 20 1C872 01 GS1280 32P042L CE CAB0 DRW1 DUO0 RIMM30 06 20 1C872 01 GS1280 32P043L CE CAB0 DRW1 DUO0 RIMM50 06 20 1C872 01 GS1280 32P045L CE CAB0 DRW1 DUO0 RIMM60 06 20 1C872 01 GS1280 32P046L CE CAB0 DRW1 DUO0 RIMM70 06 20 1C872 01 GS1280 32P047L CE CAB0 DRW1 DUO0 RIMM80...

Страница 114: ... PBM 00 nightlyFri_105 Fri_148 CAB1 DRW2 PCI 00 nightlyFri_106 Fri_149 CAB1 DRW2 PS0 00 nightlyFri_107 Fri_150 7F7FA2 CAB1 DRW2 PS1 00 nightlyFri_108 Fri_151 7F7FA2 CAB1 DRW2 IOR0 00 nightlyFri_109 Fri_152 CAB1 DRW3 PWR0 00 nightlyFri_110 Fri_153 CAB1 DRW3 DOCP 00 nightlyFri_111 Fri_154 CAB1 DRW3 PBM 00 nightlyFri_112 Fri_155 CAB1 DRW3 PCI 00 nightlyFri_113 Fri_156 CAB1 DRW3 PS1 00 nightlyFri_114 ...

Страница 115: ...ys_Serial_Num CAB1 COCP GS1280 32P CAB1 DRW0 PWR0 GS1280 32P CAB1 DRW1 PWR0 GS1280 32P CAB1 DRW1 DOCP GS1280 32P CAB1 DRW1 PBM GS1280 32P CAB1 DRW1 PCI GS1280 32P CAB1 DRW1 PS0 GS1280 32P CAB1 DRW1 PS1 GS1280 32P CAB1 DRW1 IOR0 GS1280 32P CAB1 DRW2 PWR0 GS1280 32P CAB1 DRW2 DOCP GS1280 32P CAB1 DRW2 PBM GS1280 32P CAB1 DRW2 PCI GS1280 32P CAB1 DRW2 PS0 GS1280 32P CAB1 DRW2 PS1 GS1280 32P CAB1 DRW2...

Страница 116: ...ax show grid hp hard_partition all Arguments None Options hp hard_partition Specify the name of the hard partition for which information is displayed all Display information for all partitions Examples Show grid for the case of only one hard partition MBM sh grid Powerup grid for partition Default_HP 0 1 2 3 4 5 6 7 8 9 A B C D E F 0 P P P F P Processor F Filler 1 P P P F connection connection 2 W...

Страница 117: ...tting screens full of data unless they want it cabinet cabinet Cabinet number in hex This qualifier is optional to extract the micros on this cabinet Without this qualifier show all cabinets drawer drawer Drawer number in hex This qualifier is optional to extract the micros with this drawer number Without this qualifier show all drawers dump This will display the log as a series of hex long words ...

Страница 118: ... 17 19 27 55 ENV W envmon Cover 0 Main Drawer is open from MBM 0 0 Entry 4 At 2002 04 17 19 32 13 ENV W envmon Cover 0 Main Drawer is open from MBM 0 0 Entry 5 At 2002 04 17 19 35 03 ENV W envmon Cover 0 Main Drawer is open from MBM 0 0 Entry 6 At 2002 04 18 19 45 36 ENV W envmon Cover 0 Main Drawer is open from MBM 0 0 Error log from MBM in Cabinet 0 Drawer 1 CLI E tCLImodem error log is empty Er...

Страница 119: ... 2056 06 23 19 24 17 ENV E envmon PS 0 PS0 AC failure from PBM 0 4 MBM 4 Display the most recent entries first MBM sh log reverse Error log from MBM in Cabinet 0 Drawer 0 Entry 6 At 2002 04 17 19 45 36 ENV W envmon Cover 0 Main Drawer is open from MBM 0 0 Entry 5 At 2002 04 17 19 35 03 ENV W envmon Cover 0 Main Drawer is open from MBM 0 0 Entry 4 At 2002 04 17 19 32 13 ENV W envmon Cover 0 Main Dr...

Страница 120: ... M cab 00 drw 0 01a377b0 31535020 6e614620 74657220 656e7275 PS1 Fan returne 01a377c0 6f742064 726f6e20 d to nor Entry 3 At 2002 11 25 17 08 08 Text Report 01a37780 457e0038 8 E 01a37790 492d564e 6e65282d 6e6f6d76 424d2029 NV I envmon MB 01a377a0 6163284d 30303a62 7264202c 29303a77 M cab 00 drw 0 01a377b0 30535020 73616820 65656220 6572206e PS0 has been re 01a377c0 65766f6d move Entry 4 At 2002 11...

Страница 121: ...BM in Cabinet 0 Drawer 0 Entry 4 At 2002 04 17 19 32 13 ENV W envmon Cover 0 Main Drawer is open from MBM 0 0 Entry 5 At 2002 04 17 19 35 03 ENV W envmon Cover 0 Main Drawer is open from MBM 0 0 Entry 6 At 2002 04 18 19 45 36 ENV W envmon Cover 0 Main Drawer is open from MBM 0 0 MBM See Also clear log 3 97 ...

Страница 122: ...added and the show membership command lists the new micro then the group will be reformed with the newly added micro Syntax show membership Arguments None Options None Example MBM MBM show membership Cab Drw Module MicroID IP Address In Group 1 3 PBM 103fe0a 10 254 3 1 TRUE 1 4 PBM 104fe0a 10 254 4 1 TRUE 0 2 MBM 100020a 10 2 0 1 TRUE 0 3 MBM 100030a 10 3 0 1 TRUE 0 1 MBM 100010a 10 1 0 1 TRUE 1 2...

Страница 123: ... per CPU and total memory for the system partition Show memory by partitioning assignment Examples 1 Show the entire system memory MBM sh mem same as show mem phys Cab Drw CPU Memory Size 0 0 0 1024MB 0 0 1 1024MB 0 0 2 1024MB 0 0 3 1024MB 0 0 4 1024MB 0 0 5 1024MB 0 0 6 1024MB 0 0 7 1024MB 0 1 0 1024MB 0 1 1 1024MB 0 1 2 1024MB 0 1 3 1024MB 0 1 4 1024MB 0 1 5 1024MB 0 1 6 1024MB 0 1 7 1024MB 0 2 ...

Страница 124: ...dress 0x00000008 01000000 chunk 6 size 16MB start address 0x0000000c 00000000 chunk 7 size 1008MB start address 0x0000000c 01000000 chunk 8 size 16MB start address 0x00000020 00000000 chunk 9 size 1008MB start address 0x00000020 01000000 chunk 10 size 16MB start address 0x00000024 00000000 chunk 11 size 1008MB start address 0x00000024 01000000 chunk 12 size 16MB start address 0x00000028 00000000 c...

Страница 125: ...ts None Options None Examples Display remote management status and information MBM show modem Remote System Management Settings SM escape sequence TBD OCP power switch OCP secure switch Remote user Remote access TBD Remote alert TBD Modem baud TBD Modem flow control TBD Modem password TBD Modem init string TBD Modem dial string TBD Modem alert string TBD Alert pending Most recent alert MBM 3 101 ...

Страница 126: ... CPU0 10 0 1 1 10 0 1 0 0 0 CPU1 10 0 1 2 10 0 1 0 0 0 CMM1 10 0 2 0 10 0 0 1 0 0 CPU2 10 0 2 1 10 0 2 0 0 0 CPU3 10 0 2 2 10 0 2 0 0 1 MBM 10 1 0 1 0 0 0 0 0 1 CMM0 10 1 1 0 10 1 0 1 0 1 CPU0 10 1 1 1 10 1 1 0 0 1 CPU1 10 1 1 2 10 1 1 0 0 1 CMM1 10 1 2 0 10 1 0 1 0 1 CPU2 10 1 2 1 10 1 2 0 0 1 CPU3 10 1 2 2 10 1 2 0 1 1 PBM 10 254 1 1 0 0 0 0 1 2 PBM 10 254 2 1 0 0 0 0 1 3 PBM 10 254 3 1 0 0 0 0 ...

Страница 127: ...assed XSROM tests and F indicates that the IOR failed XSROM tests and was disabled Syntax show partition hp hard_partition sp sub_partition all brief Arguments None Options hp hard_partition Hard partition name sp sub_partition Subpartition name All subpartitions under the hard partition are displayed if no subpartition is specified all All partitions brief Highlight the partition attributes numbe...

Страница 128: ...g Telnet port 323 Assigned Memory 1024MB 1 000GB CPUs Cab Drw CPU NS EW PID Type 0 0 0 0 0 0 Primary 0 0 2 0 1 2 Non primary 0 0 4 0 2 4 Non primary 0 0 6 0 3 6 Non primary 0 0 1 1 0 1 Non primary 0 0 3 1 1 3 Non primary 0 0 5 1 2 5 Non primary 0 0 7 1 3 7 Non primary IOPs SBB PCI Drawer Cab Drw IOP NS EW Cab Drw IOR Status 0 0 0 0 0 1 1 0 P 0 0 2 0 1 0 0 4 0 2 0 0 6 0 3 0 0 1 1 0 0 0 3 1 1 0 0 5 ...

Страница 129: ... 0 0 Primary 0 0 2 0 1 2 Non primary 0 0 4 0 2 4 Non primary 0 0 6 0 3 6 Non primary 0 0 1 1 0 1 Non primary 0 0 3 1 1 3 Non primary 0 0 5 1 2 5 Non primary 0 0 7 1 3 7 Non primary IOPs SBB PCI Drawer Cab Drw IOP NS EW Cab Drw IOR Status 0 0 0 0 0 1 1 0 P 0 0 2 0 1 0 0 4 0 2 0 0 6 0 3 0 0 1 1 0 0 0 3 1 1 0 0 5 1 2 0 0 7 1 3 MBM 3 Show partitions in brief format MBM sh part b Partition Name CPU Cou...

Страница 130: ...wer SBB PCI DUO n detail Arguments SBB The entire system building block and its power supply subsystem PCI The PCI drawer by cabinet and drawer number DUO n The dual processor module by cabinet and drawer number n refers to the processor module within the 8P drawer and ranges from 0 to 3 Options cabinet cabinet Cabinet number in hex If this qualifier is not used all cabinets are shown drawer drawe...

Страница 131: ...OFF ppppp ppppp 26 5 25 0 26 1 p 0 1 SBB OFF pp p ppp 30 0 24 0 p 0 1 DUO0 OFF ppppp ppppp 25 5 25 0 25 0 p 0 1 DUO1 OFF ppppp ppp pp 27 0 25 5 25 0 p 0 1 DUO2 OFF ppppp ppppp 26 0 26 1 25 0 p 0 2 SBB OFF pp p ppp 29 5 24 5 p 0 2 DUO0 OFF ppppp ppppp 26 0 26 1 25 0 p 0 2 DUO1 OFF ppppp ppppp 27 0 26 1 25 0 p 0 2 DUO2 OFF ppppp ppppp 26 5 26 1 26 1 p 0 3 SBB OFF pp p ppp 29 0 25 0 p 0 3 DUO0 OFF pp...

Страница 132: ...peratures in centigrade CMM 26 0 P CPU0 31 6 P CPU1 30 1 P Voltages EV7 Core 1 575V 1 570V P Term Volt 1 783V 1 830V P RIMM Volt 2 523V 2 496V P EV79 Core 0 000V 0 000V P CMM Volt 3 300V 3 213V P VRMs CPU RIMM Term 012345 01234 0 PPPP PPP PP MBM 4 Show the detailed environment of PCI drawer 3 in cabinet 0 MBM sh power ca 0 dr 3 pci detail PCI Drawer cabinet 0 drawer 3 Temperatures in centigrade PB...

Страница 133: ... P PBM 3 3V 3 294V P PBM 5 0V 4 915V P PCI 1 5V 1 500V P PCI 2 5V 2 540V P PCI 3 3V 3 294V P PCI 5 0V 5 100V P PCI 12 0V 12 129V P PCI VAUX 4 995V P IOR0 1 5V 1 500V P IOR0 1 8V 1 790V P IOR1 1 5V 1 500V P IOR1 1 8V 1 810V P IOR2 1 5V 1 490V P IOR2 1 8V 1 780V P IOR3 1 5V 0 000V P IOR3 1 8V 0 000V P MBM See Also power on power off 3 109 ...

Страница 134: ...is limited to 12 characters and does not apply to RIMMs Syntax show sys_serial_num Arguments None Options None Examples 1 Show the system serial number MBM sh sys_serial_num sys_serial_num MARVEL_FW16P MBM 2 Show the system serial number which has not been set MBM sh sys_serial sys_serial_num is not set MBM See Also set sys_serial_num 3 110 ...

Страница 135: ...olumn indicate which IOP connected to the IOR If nothing is displayed for IOR1 IOR2 or IOR3 either there is a standard PCI drawer with at most 1 IOR or an Expanded PCI drawer with a possible maximum of 4 IORs The Powered SBB column indicates which SBB is being powered by the power supply sub system Syntax show system Arguments None Options None Example Display system summary MBM sh sys SBBs System...

Страница 136: ...CPUs CPU0 RIMMs CPU1 RIMMs IOP0 IOP1 01 0123456789 0123456789 Cab Drw ior Cab Drw ior 0 0 P 0 0 0 p pp pppp pppp pppp pppp PCI 1 1 0 0 0 1 p pp pppp pppp pppp pppp 0 0 2 Filler 0 0 3 Filler 0 1 P 0 1 0 p pp pppp pppp pppppppppp PCI 1 3 0 0 1 1 p pp pppp pppp pppp pppp 0 1 2 Filler 0 1 3 Filler 0 2 P 0 2 0 p pp pppp pppp pppp pppp 0 2 1 p pp pppp pppp pppp pppp PCI 1 4 0 0 2 2 Filler 0 2 3 Filler 0...

Страница 137: ...time specific to each partition If delta times are not set the Default_SP of the Default_HP displays 1 for each delta time field Syntax show time Arguments None Options None Example Show the common base time and delta times of all subpartitions MBM sh time Common base time 2002 04 17 10 59 07 HP Name SP Name Delta Time Days hh mm ss hp0 Default_SP 00 00 00 00 hp1 Default_SP 01 01 01 01 MBM See Als...

Страница 138: ...ributed and supported X Unsupported not for distribution mmm 1 to 3 digits reflecting the major version followed by a dot nnn 1 to 3 digits reflecting the minor version followed by a dash sssss 1 to 5 digits reflecting the build number Syntax show version run cabinet cabinet drawer drawer CMM n PBM MBM fw fw_module Arguments CMM n The dual processor module by cabinet and drawer number with n refer...

Страница 139: ...CMMFPGA V114 SROMFW V1 0 7 XSROMFW T1 0 12 SRMFW X6 6 2914 0 1 MBM MBMFW X2 2 144 MBMFSL V2 1 1 PBMFPGA X4 1 01 XSHFPGA X3 1 03 CMMFW T2 3 2 CMMFSL V2 1 22 CMMFPGA V114 SROMFW V1 0 7 XSROMFW T1 0 12 SRMFW X6 6 2914 0 1 CMM0 CMMFW T2 3 2 CMMFSL V2 1 22 CMMFPGA V114 SROMFW V1 0 7 XSROMFW T1 0 12 SRMFW X6 6 2914 0 1 CMM1 CMMFW T2 3 2 CMMFSL V2 1 22 CMMFPGA V114 SROMFW V1 0 7 XSROMFW T1 0 12 SRMFW X6 ...

Страница 140: ...on 0 0 MBM MBMFW X2 2 144 MBMFSL V2 1 1 PBMFPGA X4 1 01 XSHFPGA X3 1 03 CMMFW T2 3 2 CMMFSL V2 1 22 CMMFPGA V114 SROMFW V1 0 7 XSROMFW T1 0 12 SRMFW X6 6 2914 MBM 3 Show the firmware version by a particular module MBM sh version fw mbmfw Local MBM cab 00 drw 0 FW version X2 2 144 built on Aug 10 2003 at 22 26 07 Cab Drw Micro FW Module Flash Firmware Revision 0 0 MBM MBMFW X2 2 144 0 1 MBM MBMFW X...

Страница 141: ...ptions None Examples 1 Telnet to a CLI session then exit using escape sequence MBM MBM telnet 10 254 2 0 Connecting to 10 254 2 0 Exit sequence is MBM Welcome GS1280 Server Manager T2 1 6 MBM MBM type MBM to close the connection Closed connection MBM 2 Telnet to a CLI session then exit using logout command MBM MBM telnet 10 254 2 0 Connecting to 10 254 2 0 Exit sequence is MBM Welcome GS1280 Serve...

Страница 142: ...0 Server Management CLI Reference 3 Telnet to a Vxworks shell for debugging then exit MBM telnet 10 1 0 1 322 Connecting to 10 1 0 1 Exit sequence is MBM 10 1 0 1 logout Closed connection MBM See Also logout connect hangup 3 118 ...

Страница 143: ...t Arguments test_num A diagnostic test number parameters Four parameters associated with the test if needed Options cabinet cabinet Cabinet number in hex If not specified defaults to 0 drawer drawer Drawer number in hex If not specified defaults to 0 CPU n The CPU by cabinet and drawer number n refers to the CPU number in the 8P drawer and ranges from 0 to 7 ew ew_coord East West coordinate of the...

Страница 144: ...t test status 03 rsvd1 00 result length 003e revision T1 0 9_ocla error number 01 Write Verify Read error rsvd2 00 error format 01 severity code 01 FRU1 0 FRU2 0 FRU3 0 FRU4 0 P1 ffff8000 00000000 Expected data written P2 00000000 00000000 Actual data received read P3 ffff8000 00000000 Failing Address P4 00000000 00000000 null P5 00000000 00000000 null P6 00000000 00000000 null P7 00000000 0000000...

Страница 145: ...y immediately sending an alert The modem must already be initialized and the sending of alerts must be enabled before this command can be issued Syntax test alert Arguments None Options None Example Test the modem connection MBM test alert TBD MBM See Also enable alert set alert set dial clear alert 3 121 ...

Страница 146: ... turns the LEDs off The default is to blink the LEDs for 60 seconds The maximum is 3600 seconds Syntax test led seconds Argument seconds The amount of time to leave the cable LEDs on or to turn them off Options None Examples 1 Blink the cable LEDs for the default amount of time 60 seconds MBM test led MBM 2 Turn off the cable LEDs MBM test led 0 MBM See Also config cables 3 122 ...

Страница 147: ...image Updating the MBMFW or MBMFSL also updates PBMFW or PBMFSL and the reverse is true NOTE This command uses TFTP communication between the MBM which requests the image and a connected PC which servers the image The individual update images are included on the AlphaServer ES47 ES80 GS1280 Firmware CD The PC must be connected to the Server Management hub via an Ethernet adapter This connection ca...

Страница 148: ...le name If not supplied the default file is used cabinet cabinet Cabinet number in hex If this qualifier is not used all cabinets are shown drawer drawer Drawer number in hex If this qualifier is not used all drawers are shown Examples 1 Update the CMM firmware in all flashes MBM update cmmfw 10 253 0 254 fi cmm3_t2_2_4 bin Update of module CMMFW completed on node 10 0 0 1 Update of module CMMFW c...

Страница 149: ...fi mbm_T2_1_7 bin Update of module MBMFW completed on node 10 0 0 1 Update of module MBMFW completed on node 10 1 0 1 Update of module MBMFW completed on node 10 254 2 0 Update of module MBMFW completed on node 10 254 5 0 Update is complete MBM See Also show version 3 125 ...

Страница 150: ...number in hex If this qualifier is not used all cabinets are shown drawer drawer Drawer number in hex If this qualifier is not used all drawers are shown Examples 1 Display the uptime of all MBMs and PBMs MBM uptime Cab Drw Module Uptime Days hh mm ss 0 0 MBM 0 15 14 31 0 1 MBM 0 15 41 12 0 2 MBM 0 15 41 12 0 3 MBM 0 00 00 19 1 1 PBM 0 15 41 12 1 2 PBM 0 15 41 12 1 3 PBM 0 15 41 12 1 4 PBM 0 15 41...

Страница 151: ... logout 3 48 mbmboot or 3 49 modify partition 3 51 power off 3 52 power on 3 54 reset 3 59 save partition 3 63 set 3 64 set alert 3 65 set baud 3 66 set dial 3 67 set escape 3 68 set flow 3 69 set init 3 70 set membership 3 71 set password 3 73 set sys_serial_num 3 74 set time 3 75 shell 3 76 show 3 77 show cable 3 78 show duo 3 80 show error 3 84 show fru 3 88 show grid 3 92 show log 3 93 show me...

Страница 152: ...ape command 3 68 set flow command 3 69 set init command 3 70 set membership 3 71 set password command 3 73 set sys_serial_num command 3 74 set time command 3 75 show cable command 3 78 show command 3 77 show duo command 3 80 show error command 3 84 show fru command 3 88 show log command 3 93 show membership 3 98 show memory command 3 99 show modem command 3 101 show network command 3 102 show part...

Отзывы: