Unit Dimensions

Unit Dimensions

Unit Dimensions

Unit Dimensions (HxWxD) 3.5 x 17.5 x 25 inches / 8.9 x 44.5 x 63.5 cm
Shipping Dimensions

Shipping Dimensions

Shipping Dimensions

Shipping Dimensions

11.25 x 23.48 x 36.25 inches / 28.57 x 59.64 x 92.07 cm

Unit Weight

Unit Weight

Unit Weight

Unit Weight

82 lbs/37 kg

Shipping Weight

Shipping Weight

Shipping Weight

Shipping Weight

89 lbs UPS and 127 lbs ERM / 40.37 kg & 57.6 kg

BTU Break Down

BTU Break Down

BTU Break Down

BTU Break Down

BTU On Line

BTU On Line

BTU On Line

BTU On Line

540 BT/hr

BTU On Battery

BTU On Battery

BTU On Battery

BTU On Battery

1138 BTU/hr

Battery Type

Battery Type

Battery Type

Battery Type

12 V, 5 AH, sealed, maintenance-free, rechargeable, valve regulated lead-
acid batteries with a 3-5 year service life at 25C (77F).

Electrical Input

Electrical Input

Electrical Input

Electrical Input

Voltage Range

Voltage Range

Voltage Range

Voltage Range

See Model Matrix for nominal and user selectable voltage settings

Frequency

Frequency

Frequency

Frequency

50/60 Hz

Online Efficiency

Online Efficiency

Online Efficiency

Online Efficiency

95%

REPO

REPO

REPO

REPO

Remote Emergency Power-Off disables AC power to load

Online Regulation

Online Regulation

Online Regulation

Online Regulation

-10% to +6% of nominal voltage

Electrical Output

Electrical Output

Electrical Output

Electrical Output

On battery Regulation

On battery Regulation

On battery Regulation

On battery Regulation

±5% of nominal voltage

Voltage Wave Form

Voltage Wave Form

Voltage Wave Form

Voltage Wave Form

Sine wave

Connections

Connections

Connections

Connections

See Model Selection Matrix; divided into 2 Load Segments

Output Protection

Output Protection

Output Protection

Output Protection

Re-settable circuit protectors

Type

Type

Type

Type

Maintenance-free, sealed, valve-regulated lead acid (VRLA)

Battery

Battery

Battery

Battery

Extended Batteries

Extended Batteries

Extended Batteries

Extended Batteries

Up to two ERMs supported

Backup Time

Backup Time

Backup Time

Backup Time

See Backup Times Chart

Recharge Time

Recharge Time

Recharge Time

Recharge Time

<3 hours to 80% usable capacity; <48 hours for complete recharge

Serial Ports

Serial Ports

Serial Ports

Serial Ports

Standard DB-9 and USB ports (ships with communication cables)

Communications

Communications

Communications

Communications

Option Slot

Option Slot

Option Slot

Option Slot

One

Option Cards

Option Cards

Option Cards

Option Cards

HP UPS Management Module

LED Indicators

LED Indicators

LED Indicators

LED Indicators

LED and switch membrane integrated into the front panel

Software

Software

Software

Software

HP Power Manager software included

Environmental and Safety

Environmental and Safety

Environmental and Safety

Environmental and Safety Operating Temperature

Operating Temperature

Operating Temperature

Operating Temperature

10°C to 40°C (50°F to 104°F); UL-tested at 25°C (77°F)

Non-operating

Non-operating

Non-operating

Non-operating
Temperature

Temperature

Temperature

Temperature

-20°C to 50°C (-4°F to 122°F)

Operating Humidity

Operating Humidity

Operating Humidity

Operating Humidity

20% to 80% (non-condensing)

Storage Humidity

Storage Humidity

Storage Humidity

Storage Humidity

5% to 95%

Operating Altitude

Operating Altitude

Operating Altitude

Operating Altitude

Up to 6,562 ft (2000 m) above sea level

Transit Altitude

Transit Altitude

Transit Altitude

Transit Altitude

49,212 ft (15,000 m) above sea level

Audible Noise

Audible Noise

Audible Noise

Audible Noise

<45db in normal operation. <50bd on battery operation

Safety Markings

Safety Markings

Safety Markings

Safety Markings

NA/JPN: UL, cUL
Int'l: GS, CE, GOST

Safety Certifications

Safety Certifications

Safety Certifications

Safety Certifications

UL1778, UL60950-1; CSA22.2 No.107.3-05,; EN60950-1 IEC62040-1-1

REPO Port

REPO Port

REPO Port

REPO Port

Meets NEC code 645-10 and 645-11and UL requirements

QuickSpecs

HP R/T3000 Uninterruptible Power System (UPS)

HP R/T3000 Uninterruptible Power System (UPS)

HP R/T3000 Uninterruptible Power System (UPS)

HP R/T3000 Uninterruptible Power System (UPS)

Technical Specifications

DA - 13417   Worldwide — Version 6 — January 9, 2011

Page 11

Содержание AF452A

Страница 1: ...s such as the HP c3000 BladeSystem In addition Extended Runtime Modules ERM are available to increase battery run time during a power outage ERMs can be used in both rack mount and tower configuration with the HP R T3000 UPS R T3000 Rackmount UPS configuration R T3000 Rackmount UPS configuration R T3000 Rackmount UPS configuration R T3000 Rackmount UPS configuration 1 Front bezel battery compartme...

Страница 2: ... JPN 2U Rackmount Uninterruptible Power System AF453A HP R T3000 3300VA INTL 2U Rackmount Uninterruptible Power System AF454A Kit Contents Kit Contents Kit Contents Kit Contents HP UPS R T3000 HP Power Management Software CD Power Products Documentation CD Depth adjustable fixed rack mounting rails mounting brackets cord retention clips Rack to Tower Conversion Kit and floor stand Communications c...

Страница 3: ...th Extended Runtime with Extended Runtime with Extended Runtime Modules Modules Modules Modules The Extended Runtime Modules are external battery modules that occupy 2U 3 5 inches of rack space each The HP UPS R T3000 supports up to two Extended Runtime Modules ERM in either rack mount or tower configuration which extend your overall battery runtime Lower Cost of Ownership Lower Cost of Ownership ...

Страница 4: ... Display LED and switch membrane integrated into the front panel with power controls and status and load indicators for easy visibility HP R T3000 UPS Front Panel HP R T3000 UPS Front Panel HP R T3000 UPS Front Panel HP R T3000 UPS Front Panel 1 Dual function LED Self Test and load indicator 10 load 7 Power on button 2 Dual function LED Battery fault and Load Indicator 25 load 8 Power off button 3...

Страница 5: ...lity Compatibility Compatibility Compatibility Compatible with all HP servers storage racks rack options and other rack mountable HP equipment for PDU options please refer to the UPS PDU compatibility matrix on www hp com products ups Optional UPS Optional UPS Optional UPS Optional UPS Management Module Management Module Management Module Management Module The HP UPS Management Module enables you ...

Страница 6: ...P UPS units is our exclusive Battery Pre Failure Warning which extends the advantage of a HP three year limited warranty by applying it to the battery before it actually fails This warranty is offered worldwide Specifically the Battery Pre Failure Warning ensures that when customers receive notification from HP Power Management Software that the battery may fail the battery is replaced free of cha...

Страница 7: ...lete information on HP Services offerings customers and resellers please visit us at http www hp com hps NOTE NOTE NOTE NOTE Additional information regarding worldwide limited warranty and technical support is available at http h18004 www1 hp com products servers platforms warranty index html NOTE NOTE NOTE NOTE For additional information on Server Services Rack and Power Options please visit http...

Страница 8: ...AF401A HP RJ45 DB89 DCE Female 5 Pack Serial Adapter AF402A HP Care Pack HP Care Pack HP Care Pack HP Care Pack HP Install Universal Power Supply 3KVA to Below 6KVA Service U4693E QuickSpecs HP R T3000 Uninterruptible Power System UPS HP R T3000 Uninterruptible Power System UPS HP R T3000 Uninterruptible Power System UPS HP R T3000 Uninterruptible Power System UPS Related Options DA 13417 Worldwid...

Страница 9: ...AC 3300 3000 L6 20P 3m cord LS12 3x IEC C13 1x IEC C 19 1x NEMA L6 20R LS23 3x IEC C13 1x IEC C 19 NOTE NOTE NOTE NOTE Includes one PDU Extension Bar Each Extension Bar has 7x C13 outlets and plugs into a C 19 on the rear of the UPS AF454A International 220 230 240 3300 3000 Detachable IEC C 20 inlet plug LS12 3x IEC C13 1x IEC C 19 LS23 3x IEC C13 1x IEC C 19 NOTE NOTE NOTE NOTE Includes one PDU ...

Страница 10: ... Int l model High Voltage NA JPN and Int l model High Voltage NA JPN and Int l model 3300VA 3000 Watt 3300VA 3000 Watt 3300VA 3000 Watt 3300VA 3000 Watt Load Percent Load Percent Load Percent Load Percent Estimated battery runtime Estimated battery runtime Estimated battery runtime Estimated battery runtime Minutes Minutes Minutes Minutes With One Extended Runtime With One Extended Runtime With On...

Страница 11: ...ed Backup Time Backup Time Backup Time Backup Time See Backup Times Chart Recharge Time Recharge Time Recharge Time Recharge Time 3 hours to 80 usable capacity 48 hours for complete recharge Serial Ports Serial Ports Serial Ports Serial Ports Standard DB 9 and USB ports ships with communication cables Communications Communications Communications Communications Option Slot Option Slot Option Slot O...

Страница 12: ... type for use by treatment facilities This information product disassembly instructions is posted on the Hewlett Packard web site at http www hp com go green These instructions may be used by recyclers and other WEEE treatment facilities as well as HP OEM customers who integrate and re sell HP equipment Copyright 2012 Hewlett Packard Development Company L P The information contained herein is subj...