Intelligent Manageability

Intelligent Manageability

Intelligent Manageability

Intelligent Manageability Free HP Power Management Software, an integrated component of HP Systems Insight Manager, the

industry-leading hardware management platform, is included with all HP R/T3000 models. The HP
Power Management Software enables you to monitor and control HP UPSs locally or remotely. This
software is a versatile, fully configurable, alert response tool that gives system administrators a full
overview of the network's conditions. It enables you to monitor system status and power conditions,
configure shut down timing, customize alert messages, and perform UPS diagnostic checks quickly and
easily.

Independently

Independently

Independently

Independently
Controllable Load

Controllable Load

Controllable Load

Controllable Load
Segments

Segments

Segments

Segments

With two load segments, you have the flexibility to configure scheduled startups and shutdowns, in
addition to independently control the separate load segments. Working in conjunction with HP Power
Management Software, the HP R/T3000 can be configured to extend the shutdown delay time for more
critical devices.

Ease of Maintenance with

Ease of Maintenance with

Ease of Maintenance with

Ease of Maintenance with
Hot-Swappable Batteries

Hot-Swappable Batteries

Hot-Swappable Batteries

Hot-Swappable Batteries

The UPS R/T3000 is designed with simple access through the front panel for hot swappable batteries.
Users can safely install new batteries without ever powering down connected server and server options.

HP Quality

HP Quality

HP Quality

HP Quality

HP's hardware qualification is the toughest in the industry. Extensive evaluation, testing, product
improvement, and an unsurpassed warranty guarantee the highest level of system protection, electrical
performance, product quality and compatibility.

Compatibility

Compatibility

Compatibility

Compatibility

Compatible with all HP servers, storage, racks, rack options, and other rack mountable HP equipment
(for PDU options please refer to the UPS/PDU compatibility matrix on 

www.hp.com/products/ups

).

Optional UPS

Optional UPS

Optional UPS

Optional UPS
Management Module

Management Module

Management Module

Management Module

The HP UPS Management Module enables you to monitor and manage power environments through
comprehensive control of HP UPSs. The HP UPS Management Module can support either a single UPS
configuration or provide additional power protection with support for dual redundant UPS configuration
for no-single-point-of-failure. The additional serial ports will provide greater power management control
and flexible monitoring.

The management module can be configured to send alert traps to HP Systems Insight Manager and other
SNMP management programs or used as a standalone management system. This flexibility enables you
to monitor and manage UPSs through the network. To facilitate day-to-day maintenance tasks, the
embedded management software provides detailed system logs.

The HP UPS Management Module provides remote management of a UPS by connecting the UPS directly
to the network. Configuration & Management of the UPS from anywhere and at anytime via a standard
web browser.

NOTE:

NOTE:

NOTE:

NOTE: For more information on the UPS Management Module please see:

http://h18004.www1.hp.com/products/servers/proliantstorage/powerprotection/software/module/
ups/index.html

 web browser.

Extended Runtime Module

Extended Runtime Module

Extended Runtime Module

Extended Runtime Module
(ERM)

(ERM)

(ERM)

(ERM)

The UPS R/T3000 supports up to two Extended Runtime Modules. Each module is a 2U (3.5 inches),
rack mountable battery module that extends your overall battery runtime.

QuickSpecs

HP R/T3000 Uninterruptible Power System (UPS)

HP R/T3000 Uninterruptible Power System (UPS)

HP R/T3000 Uninterruptible Power System (UPS)

HP R/T3000 Uninterruptible Power System (UPS)

Standard Features

DA - 13417   Worldwide — Version 6 — January 9, 2011

Page 5

Содержание AF452A

Страница 1: ...s such as the HP c3000 BladeSystem In addition Extended Runtime Modules ERM are available to increase battery run time during a power outage ERMs can be used in both rack mount and tower configuration with the HP R T3000 UPS R T3000 Rackmount UPS configuration R T3000 Rackmount UPS configuration R T3000 Rackmount UPS configuration R T3000 Rackmount UPS configuration 1 Front bezel battery compartme...

Страница 2: ... JPN 2U Rackmount Uninterruptible Power System AF453A HP R T3000 3300VA INTL 2U Rackmount Uninterruptible Power System AF454A Kit Contents Kit Contents Kit Contents Kit Contents HP UPS R T3000 HP Power Management Software CD Power Products Documentation CD Depth adjustable fixed rack mounting rails mounting brackets cord retention clips Rack to Tower Conversion Kit and floor stand Communications c...

Страница 3: ...th Extended Runtime with Extended Runtime with Extended Runtime Modules Modules Modules Modules The Extended Runtime Modules are external battery modules that occupy 2U 3 5 inches of rack space each The HP UPS R T3000 supports up to two Extended Runtime Modules ERM in either rack mount or tower configuration which extend your overall battery runtime Lower Cost of Ownership Lower Cost of Ownership ...

Страница 4: ... Display LED and switch membrane integrated into the front panel with power controls and status and load indicators for easy visibility HP R T3000 UPS Front Panel HP R T3000 UPS Front Panel HP R T3000 UPS Front Panel HP R T3000 UPS Front Panel 1 Dual function LED Self Test and load indicator 10 load 7 Power on button 2 Dual function LED Battery fault and Load Indicator 25 load 8 Power off button 3...

Страница 5: ...lity Compatibility Compatibility Compatibility Compatible with all HP servers storage racks rack options and other rack mountable HP equipment for PDU options please refer to the UPS PDU compatibility matrix on www hp com products ups Optional UPS Optional UPS Optional UPS Optional UPS Management Module Management Module Management Module Management Module The HP UPS Management Module enables you ...

Страница 6: ...P UPS units is our exclusive Battery Pre Failure Warning which extends the advantage of a HP three year limited warranty by applying it to the battery before it actually fails This warranty is offered worldwide Specifically the Battery Pre Failure Warning ensures that when customers receive notification from HP Power Management Software that the battery may fail the battery is replaced free of cha...

Страница 7: ...lete information on HP Services offerings customers and resellers please visit us at http www hp com hps NOTE NOTE NOTE NOTE Additional information regarding worldwide limited warranty and technical support is available at http h18004 www1 hp com products servers platforms warranty index html NOTE NOTE NOTE NOTE For additional information on Server Services Rack and Power Options please visit http...

Страница 8: ...AF401A HP RJ45 DB89 DCE Female 5 Pack Serial Adapter AF402A HP Care Pack HP Care Pack HP Care Pack HP Care Pack HP Install Universal Power Supply 3KVA to Below 6KVA Service U4693E QuickSpecs HP R T3000 Uninterruptible Power System UPS HP R T3000 Uninterruptible Power System UPS HP R T3000 Uninterruptible Power System UPS HP R T3000 Uninterruptible Power System UPS Related Options DA 13417 Worldwid...

Страница 9: ...AC 3300 3000 L6 20P 3m cord LS12 3x IEC C13 1x IEC C 19 1x NEMA L6 20R LS23 3x IEC C13 1x IEC C 19 NOTE NOTE NOTE NOTE Includes one PDU Extension Bar Each Extension Bar has 7x C13 outlets and plugs into a C 19 on the rear of the UPS AF454A International 220 230 240 3300 3000 Detachable IEC C 20 inlet plug LS12 3x IEC C13 1x IEC C 19 LS23 3x IEC C13 1x IEC C 19 NOTE NOTE NOTE NOTE Includes one PDU ...

Страница 10: ... Int l model High Voltage NA JPN and Int l model High Voltage NA JPN and Int l model 3300VA 3000 Watt 3300VA 3000 Watt 3300VA 3000 Watt 3300VA 3000 Watt Load Percent Load Percent Load Percent Load Percent Estimated battery runtime Estimated battery runtime Estimated battery runtime Estimated battery runtime Minutes Minutes Minutes Minutes With One Extended Runtime With One Extended Runtime With On...

Страница 11: ...ed Backup Time Backup Time Backup Time Backup Time See Backup Times Chart Recharge Time Recharge Time Recharge Time Recharge Time 3 hours to 80 usable capacity 48 hours for complete recharge Serial Ports Serial Ports Serial Ports Serial Ports Standard DB 9 and USB ports ships with communication cables Communications Communications Communications Communications Option Slot Option Slot Option Slot O...

Страница 12: ... type for use by treatment facilities This information product disassembly instructions is posted on the Hewlett Packard web site at http www hp com go green These instructions may be used by recyclers and other WEEE treatment facilities as well as HP OEM customers who integrate and re sell HP equipment Copyright 2012 Hewlett Packard Development Company L P The information contained herein is subj...

Отзывы: