background image

Key Features

Key Features

Key Features

Key Features

Increased power density with up to 5500VA / 4500 Watts of power packed in just 3U rack space
(5400 watts international)
Greater system uptime with support for Extended Runtime Modules (ERM)
Easy configuration through enhanced front panel display
Enterprise-wide intelligent manageability with bundled power management software
Support for the HP UPS Management Module that extends the power management capabilities of
the UPS
More efficient voltage regulation with revolutionary technology
Ultimate long-term battery reliability with HP Enhanced Battery Management
Enhanced system flexibility with two independently controlled load segments
Support for Remote Emergency Power Off (REPO) circuitry
Easy serviceability through modular design
Hot-Swappable Battery and Electronics Modules
Backed by a three year warranty with the first year including parts and labor. HP's Pre-Failure
warranty, and a $250,000 load protection guarantee

*

. (Certain restrictions and exclusions apply;

*Load protection guarantee available in North America only.

)

Optional upgrades include:

Extended Runtime Modules (ERMs)
Management Cards
HP R5500 UPS Tower Conversion Kit

3U Power Packed Design

3U Power Packed Design

3U Power Packed Design

3U Power Packed Design Rated near unity at 5500VA / 4500W (5400W international), the HP UPS R5500 packs more power in

space-conserving rack-mount design, allowing you to support more critical equipment in your rack.

Increase System Uptime

Increase System Uptime

Increase System Uptime

Increase System Uptime
with Extended Runtime

with Extended Runtime

with Extended Runtime

with Extended Runtime
Modules

Modules

Modules

Modules

The Extended Runtime Modules are rack mounted battery modules that occupy 3U (5.25 inches) of rack
space. The HP UPS R5500 supports up to four Extended Runtime Modules (ERM), which extend your
overall battery runtime.

Lower Cost of Ownership

Lower Cost of Ownership

Lower Cost of Ownership

Lower Cost of Ownership
with Innovative

with Innovative

with Innovative

with Innovative
Technology

Technology

Technology

Technology

The HP UPS R5500 utilizes a new industry-leading technology that continually conditions and regulates
power without using the battery, thereby increasing the life of the battery. The output voltage is
automatically regulated, based on the connected load and the input voltage.

Investment Protection with

Investment Protection with

Investment Protection with

Investment Protection with
HP Enhanced Battery

HP Enhanced Battery

HP Enhanced Battery

HP Enhanced Battery
Management

Management

Management

Management

HP UPS R5500 incorporates Enhanced Battery Management: an exclusive, patented technology that
doubles battery service life, optimizes battery recharge time, and provides advance notice of pending
battery failure. With Enhanced Battery Management, you have a lower total cost of ownership and
receive the best in the industry protection for your critical equipment.

Enhanced Flexibility

Enhanced Flexibility

Enhanced Flexibility

Enhanced Flexibility

The UPS R5500 models include four PDU Extension Bars. Each extension bar has seven C13 outlets for
powering equipment in the rack and attaches to the C19 outlets on the back of the UPS. The 6.5 foot (2
meter) cord allows the extension bars to mounted in many locations inside the rear of the rack.

QuickSpecs

HP Rack-Mountable R5500 UPS

HP Rack-Mountable R5500 UPS

HP Rack-Mountable R5500 UPS

HP Rack-Mountable R5500 UPS

Standard Features

DA - 11871   Worldwide — Version 21 — January 9, 2012

Page 2

Содержание AF416A

Страница 1: ...eir UPS R5500 by using this ERM The HP UPS models denote Extended Runtime Capable UPS models 1 REPO port 7 Load segment 2 two IEC 320 C19 receptacles and two IEC 320 C13 receptacles 2 Ground bonding screw 8 Battery circuit breaker 3 Communications port option slot 9 Cord retention clip attach locations 4 Load segment 1 circuit breaker 10 ERM connector 5 Load segment 1 two IEC 320 C19 receptacles a...

Страница 2: ...ules Modules The Extended Runtime Modules are rack mounted battery modules that occupy 3U 5 25 inches of rack space The HP UPS R5500 supports up to four Extended Runtime Modules ERM which extend your overall battery runtime Lower Cost of Ownership Lower Cost of Ownership Lower Cost of Ownership Lower Cost of Ownership with Innovative with Innovative with Innovative with Innovative Technology Techn...

Страница 3: ...cating 76 to 100 load capacity 10 ON Button 3 LED indicating 51 to 75 load capacity 11 General Alarm 4 LED indicating 26 to 50 load capacity 12 On Battery 5 LED indicating 0 to 25 load capacity 13 Bad Battery Low Battery 6 Configure mode on LED 14 Site Wiring Fault Indicator 7 Configure Button 15 Utility LED 8 TEST ALARM RESET Button A Voltage Configuration Panel Accessible only when the front bez...

Страница 4: ...n the industry Extensive evaluation testing product improvement and an unsurpassed warranty guarantee the highest level of system protection electrical performance product quality and compatibility Compatibility Compatibility Compatibility Compatibility Compatible with all HP servers storage racks rack options and other rack mountable HP equipment For PDU options please refer to the UPS PDU compat...

Страница 5: ...er For servers or storage systems installed within a rack service also covers all HP qualified rack options installed within the same rack NOTE NOTE NOTE NOTE For more information on HP Care Pack Services contact any of our worldwide sales offices or resellers or visit our worldwide web site on the internet at http www hp com hps carepack NOTE NOTE NOTE NOTE For more complete information on HP Ser...

Страница 6: ...ration Management of the UPS from anywhere and at anytime via a standard web browser NOTE NOTE NOTE NOTE For more information on the UPS Management Module please see http h18004 www1 hp com products servers proliantstorage powerprotection software module ups index html web browser Extended Runtime Module Extended Runtime Module Extended Runtime Module Extended Runtime Module ERM R5500 ERM R5500 ER...

Страница 7: ... AF402A HP R5500 VA Extended Runtime Module NOTE NOTE NOTE NOTE 0D1 will appear after the part number on the sales order if HP factory integration is indicated AF417A HP Care Pack Services HP Care Pack Services HP Care Pack Services HP Care Pack Services HP Install Universal Power Supply 3KVA to Below 6KVA Service U4693E QuickSpecs HP Rack Mountable R5500 UPS HP Rack Mountable R5500 UPS HP Rack Mo...

Страница 8: ...ed receptacle LS1 1 x L6 30R for NA JPN model AF416A International 220 230 240 if set at 200 208 6000 5400 then 5000 4500 IEC 309 32Amp 3m cord LS1 15A CB 2 x C19 2 x C13 LS2 15A CB 2 x C19 2 x C13 Plus one pigtailed receptacle LS1 1 x IEC 309 32Amp for Int l model Factory default setting Kit Contents Kit Contents Kit Contents Kit Contents HP UPS R5500 HP Power Management Software CD Power Product...

Страница 9: ... Int l model 6000 VA 5400 Watt Int l model 6000 VA 5400 Watt Int l model 6000 VA 5400 Watt Int l model 6000 VA 5400 Watt Load Percent Load Percent Load Percent Load Percent With Standby Battery With Standby Battery With Standby Battery With Standby Battery Minutes Minutes Minutes Minutes With One Extended With One Extended With One Extended With One Extended Runtime Module Runtime Module Runtime M...

Страница 10: ...cid VRLA Extended Batteries Extended Batteries Extended Batteries Extended Batteries Up to four ERMs supported Backup Time Backup Time Backup Time Backup Time See Backup Times Chart Recharge Time Recharge Time Recharge Time Recharge Time 3 hours to 80 usable capacity 48 hours for complete recharge Battery String Voltage Battery String Voltage Battery String Voltage Battery String Voltage 240V Batt...

Страница 11: ... please go to http www hp com go green To recycle your product please go to http www hp com go green or contact your nearest HP sales office Products returned to HP will be recycled recovered or disposed of in a responsible manner The EU WEEE directive 2002 95 EC requires manufacturers to provide treatment information for each product type for use by treatment facilities This information product d...

Отзывы: