background image

 
The most dense, most power packed UPS available - offering HP customers more watts per U than any other UPS - allowing for more
valuable rack space to be utilized by all your server, storage and networking equipment.

The leading edge HP UPS R5500 Uninterruptible Power System features a slim 3U rack-mount design, offering up to 4500 Watts of
true power (5400 watts international). This new rack-space saving design allows more support for critical rack mountable
equipment. This product brings unprecedented power density and innovative features to the proven HP family of rack-mountable UPS
products.

The UPS R5500 is a high power density solution, designed for customers who want to provide power protection in space-constrained
rack enterprise environments. In addition, this new UPS R5500 has the capability to be connected to an optional Extended Runtime
Module (ERM). Customers can further increase the run-time on their UPS R5500 by using this ERM. The HP UPS "" models denote
"Extended Runtime Capable" UPS models.

 

 

1. REPO port

7.

Load segment 2 (two IEC-320-C19 receptacles and two IEC-
320-C13 receptacles)

2. Ground bonding screw

8.

Battery circuit breaker

3. Communications port/option slot

9.

Cord retention clip attach. locations

4. Load segment 1 circuit breaker

10. ERM connector

5. Load segment 1 (two IEC-320-C19 receptacles and two IEC-

320-C13 receptacles)

11. PDU output NEMA L6-30 receptacle (NA/JPN) or 32 A IEC-

309 receptacle (INTL) associated with load segment 1

6. Load segment 2 circuit breaker

12. Power cord with NEMA L6-30 plug (NA/JPN) or 32 A IEC-

309 plug (INTL)

Models

Models

Models

Models

NOTE:

NOTE:

NOTE:

NOTE: #0D1 will appear after the part number on the sales order if HP factory integration is indicated.

HP R5500 6000VA INTL 3U Rackmount Uninterruptible Power System

AF416A

HP R5500 5000kVA NA/JP 3U Rackmount Uninterruptible Power System

AF426A

QuickSpecs

HP Rack-Mountable R5500 UPS

HP Rack-Mountable R5500 UPS

HP Rack-Mountable R5500 UPS

HP Rack-Mountable R5500 UPS

Overview

DA - 11871   Worldwide — Version 21 — January 9, 2012

Page 1

Содержание AF416A

Страница 1: ...eir UPS R5500 by using this ERM The HP UPS models denote Extended Runtime Capable UPS models 1 REPO port 7 Load segment 2 two IEC 320 C19 receptacles and two IEC 320 C13 receptacles 2 Ground bonding screw 8 Battery circuit breaker 3 Communications port option slot 9 Cord retention clip attach locations 4 Load segment 1 circuit breaker 10 ERM connector 5 Load segment 1 two IEC 320 C19 receptacles a...

Страница 2: ...ules Modules The Extended Runtime Modules are rack mounted battery modules that occupy 3U 5 25 inches of rack space The HP UPS R5500 supports up to four Extended Runtime Modules ERM which extend your overall battery runtime Lower Cost of Ownership Lower Cost of Ownership Lower Cost of Ownership Lower Cost of Ownership with Innovative with Innovative with Innovative with Innovative Technology Techn...

Страница 3: ...cating 76 to 100 load capacity 10 ON Button 3 LED indicating 51 to 75 load capacity 11 General Alarm 4 LED indicating 26 to 50 load capacity 12 On Battery 5 LED indicating 0 to 25 load capacity 13 Bad Battery Low Battery 6 Configure mode on LED 14 Site Wiring Fault Indicator 7 Configure Button 15 Utility LED 8 TEST ALARM RESET Button A Voltage Configuration Panel Accessible only when the front bez...

Страница 4: ...n the industry Extensive evaluation testing product improvement and an unsurpassed warranty guarantee the highest level of system protection electrical performance product quality and compatibility Compatibility Compatibility Compatibility Compatibility Compatible with all HP servers storage racks rack options and other rack mountable HP equipment For PDU options please refer to the UPS PDU compat...

Страница 5: ...er For servers or storage systems installed within a rack service also covers all HP qualified rack options installed within the same rack NOTE NOTE NOTE NOTE For more information on HP Care Pack Services contact any of our worldwide sales offices or resellers or visit our worldwide web site on the internet at http www hp com hps carepack NOTE NOTE NOTE NOTE For more complete information on HP Ser...

Страница 6: ...ration Management of the UPS from anywhere and at anytime via a standard web browser NOTE NOTE NOTE NOTE For more information on the UPS Management Module please see http h18004 www1 hp com products servers proliantstorage powerprotection software module ups index html web browser Extended Runtime Module Extended Runtime Module Extended Runtime Module Extended Runtime Module ERM R5500 ERM R5500 ER...

Страница 7: ... AF402A HP R5500 VA Extended Runtime Module NOTE NOTE NOTE NOTE 0D1 will appear after the part number on the sales order if HP factory integration is indicated AF417A HP Care Pack Services HP Care Pack Services HP Care Pack Services HP Care Pack Services HP Install Universal Power Supply 3KVA to Below 6KVA Service U4693E QuickSpecs HP Rack Mountable R5500 UPS HP Rack Mountable R5500 UPS HP Rack Mo...

Страница 8: ...ed receptacle LS1 1 x L6 30R for NA JPN model AF416A International 220 230 240 if set at 200 208 6000 5400 then 5000 4500 IEC 309 32Amp 3m cord LS1 15A CB 2 x C19 2 x C13 LS2 15A CB 2 x C19 2 x C13 Plus one pigtailed receptacle LS1 1 x IEC 309 32Amp for Int l model Factory default setting Kit Contents Kit Contents Kit Contents Kit Contents HP UPS R5500 HP Power Management Software CD Power Product...

Страница 9: ... Int l model 6000 VA 5400 Watt Int l model 6000 VA 5400 Watt Int l model 6000 VA 5400 Watt Int l model 6000 VA 5400 Watt Load Percent Load Percent Load Percent Load Percent With Standby Battery With Standby Battery With Standby Battery With Standby Battery Minutes Minutes Minutes Minutes With One Extended With One Extended With One Extended With One Extended Runtime Module Runtime Module Runtime M...

Страница 10: ...cid VRLA Extended Batteries Extended Batteries Extended Batteries Extended Batteries Up to four ERMs supported Backup Time Backup Time Backup Time Backup Time See Backup Times Chart Recharge Time Recharge Time Recharge Time Recharge Time 3 hours to 80 usable capacity 48 hours for complete recharge Battery String Voltage Battery String Voltage Battery String Voltage Battery String Voltage 240V Batt...

Страница 11: ... please go to http www hp com go green To recycle your product please go to http www hp com go green or contact your nearest HP sales office Products returned to HP will be recycled recovered or disposed of in a responsible manner The EU WEEE directive 2002 95 EC requires manufacturers to provide treatment information for each product type for use by treatment facilities This information product d...

Отзывы: