
76
Maintenance
0000: End of Text
Open the library door and check the picker for a tape
cartridge. If so, remove the tape and place it into an
empty slot. Close the library door to initiate an inventory.
One or more tape drives fail during startup.
•
Verify the OCP does not show the drive power as off.
•
Check power supply indicator for power to that
module.
•
Check that the drive is properly cabled and ready.
•
Check the link indicators on the e2400-FC 2G
interface controllers for a valid link to the drives.
•
Check whether the FAULT indicator is lit on the back
of the drive. If so, diagnose the problem.
•
Ensure the tape drive has the appropriate firmware.
Table 17
Startup problems (continued)
Problem
Corrective action
Содержание AD560-96002
Страница 16: ...16 Library overview Figure 3 Example of a fully expanded Enterprise Modular Library E Series 10449 3 ...
Страница 46: ...46 Installing the Library ...
Страница 52: ...52 Preparation for use ...
Страница 96: ...96 Maintenance ...
Страница 100: ...100 Moving the library ...
Страница 128: ...128 Installing a redundant PDU ...