444 Configuring McData Open Fabric mode
You can use the
cfgSize
command to check both the maximum available size and the currently saved
size. If you believe you are approaching the maximum, you can save a partially completed zoning
configuration and use the
cfgSize
command to determine the remaining space
Zone name restrictions
The name field must contain the ASCII characters that actually specify the name, not including any required
fill bytes. Names must follow these rules:
•
Length must be between 1 and 64 characters.
•
All characters must be 7-bit ASCII.
•
The first character must be a letter, which can be either upper case (A-Z) or lower case (a-z).
•
Any character other than the first character must be lower case (a-z), upper case (A-Z), a single-digit
number (0-9), dash (-), or underscore (_).
Enabling and disabling interoperability mode
Before enabling interoperability mode, inspect the individual fabrics for compatibility.
•
Make sure that zones meet the zone criteria and restrictions listed in ”
Zoning restrictions
” on
page 443).
•
Use the
msplMgmtDeactivate
command to disable any platform management functions. (Refer to
the
Fabric OS Command Reference Manual
for additional command information).
To enable interoperability mode
1.
Verify that you have implemented all the prerequisites necessary to enable interoperability mode on the
fabric (refer to ”
Configuration recommendations
” and ”
Configuration restrictions
” on page 442.
2.
Connect to the switch and log in as admin.
3.
Enter the
switchDisable
command to disable the switch.
4.
Use the
configure
command to set the domain ID to a number in the range from 97 to 126. (For
detailed instructions, refer to ”
Working with domain IDs
” on page 40.)
5.
Enter the
interopmode 1
command to enable interoperability. This command resets a number of
parameters and enables interactive mode.
6.
You
must
reboot
the switch after changing the interoperability mode:
7.
Repeat
step 2
through
step 6
on all HP StorageWorks switches in the fabric.
8.
Enable interoperability on each non-HP StorageWorks switch (refer to the switch documentation).
9.
After enabling interoperability mode on all switches, physically connect the non-HP StorageWorks
switches into the fabric, one at a time.
To disable interoperability mode
1.
Connect to the switch and log in as admin.
2.
Enter the
switchDisable
command to disable the switch.
switch:admin>
switchdisable
switch:admin>
configure
Configure...
Fabric Parameters (yes, y, no, n): [no]
y
Domain (1...239): [1] 97
...
switch:admin>
interopmode 1
Please make sure the MS Platform service is disabled.
Please run "msPlMgmtDeactivate" command to disable the Platform service.
The switch effective configuration will be lost when the operating mode is changed;
do you want to continue? (yes, y, no, n): [no]
y
Interopmode is enabled
Note: You must reboot this switch for the new change to take effect.
switch:admin>
Содержание AA979A - StorageWorks SAN Switch 2/8V
Страница 1: ...HP StorageWorks Fabric OS 5 3 x administrator guide Part number 5697 0244 November 2009 ...
Страница 16: ...16 ...
Страница 20: ...18 ...
Страница 24: ...24 Introducing Fabric OS CLI procedures ...
Страница 116: ...118 Maintaining configurations ...
Страница 170: ...172 Managing administrative domains ...
Страница 200: ...202 Installing and maintaining firmware ...
Страница 222: ...224 Routing traffic ...
Страница 274: ...286 Administering FICON fabrics ...
Страница 294: ...306 Working with diagnostic features ...
Страница 350: ...362 Administering Extended Fabrics ...
Страница 438: ...440 Configuring the PID format ...
Страница 444: ...446 Configuring McData Open Fabric mode ...
Страница 450: ...452 Understanding legacy password behaviour ...