Fabric OS 5.3.0 administrator guide 411
4.
Enter the
portCfgShow
command to verify the port is persistently enabled as shown below:
Defining the IP interface of each virtual port
Specify the IP interface on the virtual port using the
portCfg
command. You can define up to eight IP
interfaces per GbE port. The syntax for this command is as follows:
portcfg ipif
[
slot/
][
ge
]
port args
:
To create IP interfaces:
create ipaddr netmask mtu_size
To delete IP interfaces:
delete ipaddr
Use the
portShow
command to display all IP interfaces on a particular GbE port. Note that fabrics
connected through FCIP are merged (unless they are connected as VEX_Ports).
To display IP interfaces on the specified GbE port:
portshow ipif [
slot
/][ge]
port
switch:admin06> portcfgpersistentenable 8/16
switch:admin06> portcfgpersistentenable 8/17
switch:admin06> portcfgpersistentenable 8/18
switch:admin06> portcfgpersistentenable 8/19
switch:admin06> portcfgshow
Ports of Slot 8 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
-----------------+--+--+--+--+----+--+--+--+----+--+--+--+----+--+--+--
Speed AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN
Trunk Port ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON
Long Distance .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
VC Link Init .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
Locked L_Port .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
Locked G_Port .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
Disabled E_Port .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
ISL R_RDY Mode .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
RSCN Suppressed .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
Persistent DisableON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON
NPIV capability ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON
EX Port .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
Mirror Port .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
Ports of Slot 8 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31
-----------------+--+--+--+--+----+--+--+--+----+--+--+--+----+--+--+--
Speed AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN
Trunk Port ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON
Long Distance .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
VC Link Init .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
Locked L_Port .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
Locked G_Port .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
Disabled E_Port .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
ISL R_RDY Mode .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
RSCN Suppressed .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
Persistent Disable.. .. .. .. ON ON ON ON ON ON ON ON ON ON ON ON
NPIV capability ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON
EX Port .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
where AN:AutoNegotiate, ..:OFF, ??:INVALID.
LM:L0.5
switch:admin06>
Содержание AA979A - StorageWorks SAN Switch 2/8V
Страница 1: ...HP StorageWorks Fabric OS 5 3 x administrator guide Part number 5697 0244 November 2009 ...
Страница 16: ...16 ...
Страница 20: ...18 ...
Страница 24: ...24 Introducing Fabric OS CLI procedures ...
Страница 116: ...118 Maintaining configurations ...
Страница 170: ...172 Managing administrative domains ...
Страница 200: ...202 Installing and maintaining firmware ...
Страница 222: ...224 Routing traffic ...
Страница 274: ...286 Administering FICON fabrics ...
Страница 294: ...306 Working with diagnostic features ...
Страница 350: ...362 Administering Extended Fabrics ...
Страница 438: ...440 Configuring the PID format ...
Страница 444: ...446 Configuring McData Open Fabric mode ...
Страница 450: ...452 Understanding legacy password behaviour ...