Fabric OS 5.3.0 administrator guide 431
1.
Determine if the current switch firmware versions meet the minimum supported version levels.
Table 103
lists the earliest Fabric OS version levels that support Extended Edge PID format. Use this
table to determine if you need to upgrade the firmware in the switches in your fabric before you change
the PID format.
2.
Update switch firmware as necessary.
a.
Use the
fabricShow
command to verify the total number of switches in the fabric.
b.
Download the correct firmware version to each switch as necessary.
c.
Reboot all switches.
d.
Verify that the switches form a single fabric and that all domain IDs do not change after forming the
fabric.
e.
Verify that the number of switches is the same.
3.
Disable the switch by entering the
switchDisable
command.
4.
Change the switch configuration in the fabric to Extended Edge PID format.
a.
Configure Extended Edge PID (Format 2) on each switch. (See
Figure 18
for a sample configure
command on a switch running Fabric OS v3.1.2 and later and see
Figure 18
for a sample configure
command on a switch running Fabric OS 4.2.0 and later.)
b.
Run the
switchEnable
command all switches.
c.
Verify that all the switches form a fabric.
d.
Use the
switchShow
command to verify the interswitch links (ISLs) are correct and the device links
are correct.
e.
Use the
fabricShow
command to verify that the number of switches are the same as those when
starting this procedure.
f.
Use the
nsAllShow
command to verify the total number of devices is the same as those when
starting this procedure.
g.
For dual fabrics, repeat steps 1 through 5 for the other fabric.
Table 103
Earliest Fabric OS versions for extended edge PID format
HP
StorageWorks
1 GB switches
SAN Switch
2/8 EL
and
SAN Switch
2/16
SAN Switch 2/8V,
SAN Switch 2/16V,
SAN Switch 2/32,
Core Switch 2/64,
SAN Director 2/128
Switches
4/16 SAN
Switch and
4/8 SAN
Switch,
4/256 SAN
Director
Switches
4/64 SAN
Switch and
400 MP
Router
v2.6.2
v3.1.2
v4.2.0
v5.0.1
5.1.x
Содержание AA979A - StorageWorks SAN Switch 2/8V
Страница 1: ...HP StorageWorks Fabric OS 5 3 x administrator guide Part number 5697 0244 November 2009 ...
Страница 16: ...16 ...
Страница 20: ...18 ...
Страница 24: ...24 Introducing Fabric OS CLI procedures ...
Страница 116: ...118 Maintaining configurations ...
Страница 170: ...172 Managing administrative domains ...
Страница 200: ...202 Installing and maintaining firmware ...
Страница 222: ...224 Routing traffic ...
Страница 274: ...286 Administering FICON fabrics ...
Страница 294: ...306 Working with diagnostic features ...
Страница 350: ...362 Administering Extended Fabrics ...
Страница 438: ...440 Configuring the PID format ...
Страница 444: ...446 Configuring McData Open Fabric mode ...
Страница 450: ...452 Understanding legacy password behaviour ...