Installing the SAN Switch 2/8
55
hp StorageWorks SAN Switch 2/8 Installation Guide
Connecting a Cable to an SFP Module
Use these steps to connect the SFPs and cables to SAN Switch 2/8 ports as
required.
Note:
The ports and cables used in trunking groups must meet specific requirements.
For a list of these requirements, refer to the
hp StorageWorks ISL Trunking
V3.0.x/V4.0.x
User Guide
.
1. Remove the shipping plugs from the appropriate ports.
2. Position the SFP so that the key (the tab near the cable-end of the SFP) is on
top.
3. Insert the SFP into the port until it is firmly seated and the latching
mechanism clicks.
Note:
The SFP is keyed so that it can only be inserted with the correct orientation into
the port. If the SFP does not slide in easily, check the orientation.