8
Installing the switch in a 19-inch rack
Every A5500 HI switch comes with a pair of mounting brackets (see
) for rack mounting.
Figure 6
Rack-mounting procedure
Figure 7
Mounting bracket
(1) Hole for attaching to a rack (by using an M6 screw)
(2) Hole for attaching to the switch chassis
Prerequisites
If you are installing an LSP5GP8P0 (JG314A) interface card, make sure the rack depth is 800 mm (31.50
in) or 1000 mm (39.37 in). This card adds 69.75 mm (2.75 in) to the chassis depth (see
) in
addition to the clearance required for installing transceiver modules and cables.
Attaching the mounting brackets to the chassis
To attach the mounting brackets to the chassis:
1.
Identify the front mounting position (see
) and rear mounting position (see
) on the
two sides of the chassis.
2.
Align the round holes in the wide flange of one front mounting bracket with the screw holes in the
front or rear mounting position on one side of the chassis
3.
Use M4 screws (supplied with the switch) to attach the mounting bracket to the chassis.
4.
Repeat the preceding two steps to attach the other mounting bracket to the other side of the
chassis.
NOTE:
The screw holes in the figures in this section are for illustration only.
Содержание A5500 HI Series
Страница 1: ...HP A5500 HI Switch Series Installation Guide Part number 5998 2373 Document version 6W100 20111031 ...
Страница 5: ...iii SFP port LED 55 Interface card status LED 55 Port LED on the interface card 56 Index 57 ...
Страница 41: ...36 Figure 36 Connecting the switches in the same rack Figure 37 IRF fabric topology ...
Страница 54: ...49 Figure 40 CX4 cable assembly 1 Pull latch 2 Connector ...