Updating the Hub Firmware
The Set System OID Menu appears with the new setting.
Set System OID Menu: [current = 1.3.6.1.4.1.11.2.3.7.5.10]
1. Return to Manufacturing Settings Menu
or enter new system OID suffix in dotted decimal format
The suffix entered will be appended to 1.3.6.1.4.1
example: if desired system OID is 1.3.6.1.4.1.2.3.4, then enter
2.3.4
>
7. Verify that the setting is correct, then enter
1
to return to the Manufacturing Settings
Menu.
Manufacturing Settings Menu:
1. Return to Main Menu
2. Set sysdescr [current = HP A3724A FC-AL Shortwave Hub]
3. Set system OID [current = 1.3.6.1.4.1.11.2.3.7.5.10]
4. Toggle port bypass persistence mode [current = Enabled]
>
If you are using Fibre Channel Manager to manage the hub, the bypass persistence setting
controls the behavior of bypassed ports when the hub is power cycled or reset.
If the hub is power-cycled or reset with bypass persistence
disabled
, the hub
automatically enables all ports that were previously bypassed in Fibre Channel Manager. If
the hub is reset with bypass persistence
enabled
, the hub continues to bypass ports that
were bypassed in Fibre Channel Manager.
8. Enter
4
to disable port bypass persistence. Verify that the port bypass persistence mode
is
disabled
.
Manufacturing Settings Menu:
1. Return to Main Menu
2. Set sysdescr [current = HP A3724A FC-AL Shortwave Hub]
3. Set system OID [current = 1.3.6.1.4.1.11.2.3.7.5.10]
4. Toggle port bypass persistence mode [current = Disabled]
>
9. Enter
1
to return to the Main menu.
10. Exit the terminal emulator application and disconnect the serial cable from the hub and
the PC.
Содержание A3724A - SureStore E Hub S10
Страница 1: ...Hewlett Packard SureStore E Hub Models S10 and L10 Service and User Manual ...
Страница 2: ......
Страница 8: ...6 Regulatory Statements 110 Laser Safety 113 Glossary 117 Index 121 ...
Страница 12: ...10 ...
Страница 68: ...66 Viewing Hub Information ...
Страница 86: ...84 If Firmware Upgrade Appears to Fail ...
Страница 87: ...Maintenance and Replacement 85 5 MAINTENANCE AND REPLACEMENT Introduction Maintenance Replacing the Fan Module ...
Страница 114: ...112 Regulatory Statements E VCCI Statement Japan ...
Страница 118: ...116 Laser Safety Declaration of Conformity ...
Страница 122: ...120 Glossary ...
Страница 130: ...128 Index ...
Страница 133: ......