Supported Topologies
19
P
ro
d
u
c
t D
e
s
c
ri
p
tio
n
Cascaded Long-Wave Hub Topology
Cascaded FC-AL, non-OFC, model L10 long-wave hubs use the long-wave port for the hub-
to-hub connection. The maximum supported distance between cascaded long-wave hubs
with single-mode 9 micron cable is 3 km. The maximum distance between a server and FC-
AL devices on cascaded long-wave hubs is, therefore, 4000 meters (500 m + 3000 m +
500 m). Under certain conditions, cascaded long-wave hubs are supported up to 10,000
meters (10 km) (see page 105 for more information). The 10-km capability only applies to
long-wave hubs connected to HP-UX servers.
Caution
When cascading long-wave hubs, only connect long-wave ports to long-wave
ports or short-wave ports to short-wave ports.
Ports 1 through 9 on each long-wave hub are for connections to FC-AL devices. Ports 1
through 9 can also be used in a cascaded configuration; however, the maximum distance
between hubs decreases from 3000 meters to 500 meters.
Figure 6
Example Topology: Cascaded Long-Wave Hubs
...
...
...
...
... ...
...
...
...
... ...
...
...
...
......
...
...
...
... ...
...
...
...
......
...
...
...
... ...
...
...
...
... ...
...
...
...
... ...
...
...
...
... ...
...
...
...
... ...
.
..
..
.
...
...
...
...
......
...
...
...
... ...
...
...
...
... ...
...
...
...
... ...
...
...
...
......
...
...
...
... ...
...
...
...
... ...
...
...
...
... ...
...
...
...
... ...
...
...
...
... ...
.
..
..
.
3000 m (long-wave port to long-wave port only)
500 m
500 m
FC-AL Devices
FC-AL Devices
Maximum distance between
server and FC-AL device = 4000 m
NOTE: Under certain conditions, the
maximum distance between an HP-UX
server and FC-AL device can be 11,000 m.
HP-UX Server
or
HP NetServer
NOTE: Connecting HP-UX
servers and HP NetServers
to the same hub is NOT
a supported configuration.
model L10 hub
model L10 hub
Содержание A3724A - SureStore E Hub S10
Страница 1: ...Hewlett Packard SureStore E Hub Models S10 and L10 Service and User Manual ...
Страница 2: ......
Страница 8: ...6 Regulatory Statements 110 Laser Safety 113 Glossary 117 Index 121 ...
Страница 12: ...10 ...
Страница 68: ...66 Viewing Hub Information ...
Страница 86: ...84 If Firmware Upgrade Appears to Fail ...
Страница 87: ...Maintenance and Replacement 85 5 MAINTENANCE AND REPLACEMENT Introduction Maintenance Replacing the Fan Module ...
Страница 114: ...112 Regulatory Statements E VCCI Statement Japan ...
Страница 118: ...116 Laser Safety Declaration of Conformity ...
Страница 122: ...120 Glossary ...
Страница 130: ...128 Index ...
Страница 133: ......