Procedure 3: Verify Hub Operation
4. Verify that the 10Base-T port is operating properly. Insert an ethernet cable that is
connected to the LAN into the 10Base-T port, and verify that the 10Base-T status LED
turns on. (The status LED may begin flashing.)
5. Set the hub IP address and configure the hub as described in chapter 3, RS-232 Interface
Functions.
6. Verify the connection between the HP-UX server and the hub. At the management server
where Fibre Channel Manager is or will be installed, execute the following command:
/etc/ping <hub IP address>
Example:
/etc/ping 15.43.214.13
Fibre Channel Manager requires HP-UX 10.20 or 11.0 on the management server.
If you are unable to ping the hub, refer to If the Management Server Cannot Ping the
Hub on page 78.
7. Unplug the hub.