Chapter 3
Troubleshooting
Troubleshooting Using Online Support Tools
24
F
First entry
L
Last entry
J
Jump to entry number
V
View mode configuration (text, keyword, hex)
?
Display this Help menu
Ctrl-B
Quit and return to the Main Menu
Step 4. Select v, then t to change the display to text mode:
Display Mode Configuration:
H - Hex mode
Current -> K - Keyword mode
T - Text mode
Enter new value, or [Q] to Quit:
T
Step 5. To decode the blinking state of System LED, review the entire SEL and look at events with alert
level 3 and above.
For example:
Log Entry 24: 14 Feb 2003 15:27:02
Alert Level 3: Warning
Keyword: Type-02 1b0800 1771520
Hot Swap Cage: SCSI cable removed
Logged by: BMC;
Sensor: Cable / Interconnect - SCSI ChExt Cable
Data1: Device Removed/Device Absent
0x203E4D0AC6020220 FFFF0008F61B0300
Log Entry 73: 00:00:12
Alert Level 3: Warning
Keyword: Type-02 050301 328449
The server's built-in sensors have detected an open chassis door.
Logged by: BMC;
Sensor: Physical Security - Chassis Open
Data1: State Asserted
0x200000000C020570 FFFF010302050300
Содержание 9000 rp4440
Страница 6: ...Contents 6 ...
Страница 83: ...Chapter 4 Removing and Replacing Components OLX Dividers 83 Figure 4 30 OLX Slider Gate Bracket CLOSED OPEN ...
Страница 109: ...Chapter 4 Removing and Replacing Components Display Board 109 Figure 4 41 Display Board Removal and Replacement ...
Страница 114: ...Chapter 4 Removing and Replacing Components QuickFind Diagnostic Board 114 ...
Страница 118: ...Parts Information Field Replaceable Parts FRU List Appendix A 118 ...
Страница 122: ...System I O Board Switches and Jumpers Appendix B 122 ...