HP 85038 family of calibration kits

The HP 85038A calibration kit contains open circuits,
short circuits, and terminations with both male and
female 7-16 connectors.  More economical versions of
this kit are available: the HP 85038M contains only
male devices, and the HP 85038F provides only female
devices (see following table).  Each kit contains a flop-
py disk with the calibration kit definition for use with
HP 8712, 8714, 8753, 8719, 8720, 8722, and 8510C net-
work analyzers.

Contents of 7-16 Calibration Kits

Description

HP Part Number HP 85038A

HP 85038M HP 85038F

Open circuit, female

85038-80002

X

X

Open circuit, male

85038-80003

X

X

Short circuit, female 85038-80004

X

X

Short circuit, male

85038-80005

X

X

Termination, female

85038-80006

X

X

Termination, male

85038-80007

X

X

7-16 adapter, 
female-to-female

11906-80016

X

7-16 adapter,
male-to-male

11906-80015

X

Calibration kit data disk 85038-10001

X

X

X

Torque wrench

8710-2175

X

Open-end wrench

8710-2174

X

Specifications

Frequency coverage

dc to 7.5 GHz
(usable to 8 GHz)

Nominal impedance

50 ohms

Open circuits

Reflection phase 
± 1 degree from nominal

Short circuits

Reflection phase
±1 degree from nominal

Terminations:

Return loss > 40 dB

7-16 to 7-16 adapters

Return loss > 40 dB 
(VSWR < 1.02)

7-16 to 50 ohm type-N 

Return loss > 36 dB

adapters 

(VSWR < 1.03)

7-16 to 7-mm adapters 

Return loss > 38 dB
(VSWR < 1.025)

7-16 to 3.5-mm adapters

Return loss > 34 dB
(VSWR < 1.04)

HP 11906 family of adapter kits

The HP 11906 family consists of four adapter kits:

HP 11906A  7-16 to 7-16 adapter kit

Description

Quantity

HP Part Number

7-16 male-to-male adapter

1

11906-80015

7-16 female-to-female adapter

1

11906-80016

7-16 male-to-female adapter

2

11906-80017

HP 11906B  7-16 to 50-Ohm type-N adapter kit

Description

Quantity

HP Part Number

Type-N male to 

7-16 male adapter

1

11906-80007

Type-N female to

7-16 female adapter

1

11906-80008

Type-N female to

7-16 male adapter

1

11906-80009

Type-N male to

7-16 female adapter

1

11906-80010

HP 11906C  7-16 to 7-mm adapter kit

Description

Quantity      HP Part Number

7-mm to 7-16 male adapter

2

11906-80012

7-mm to 7-16 female adapter

2

11906-80013

HP 11906D  7-16 to 3.5-mm adapter kit

Description

Quantity      HP Part Number

3.5-mm male to

7-16 male adapter

1

11906-80002

3.5-mm male to

7-16 female adapter

1

11906-80005

3.5-mm female to

7-16 male adapter

1

11906-80004

3.5-mm female to

7-16 female adapter

1

11906-80003

HP 85039B type-F calibration kit

Contains a set of 75-ohm type-F standards to calibrate
the HP 8753ES with a 75-ohm test set for the mea-
surement of devices with type-F connectors. 

Includes

HP part number

F-male 75-ohm termination 

85039-60007

F-female 75-ohm termination 85039-60004   

Specifications for termination

DC to 1 GHz 

RL 

45 dB

1 to 3 GHz 

RL 

38 dB

F-male 75-ohm short 

85039-60008 

F-female 75-ohm short

85039-60003

F-male 75-ohm open

85039-60009

F-female 75-ohm open

85039-60005

F-female to F-female

75-ohm adapter

85039-60002

F-male to F-male

75-ohm adapter 

85039-60006

Typical type-F adapter 

characteristics 

DC to 1 GHz 

RL 

40 dB

1 to 3 GHz

RL 

32 dB

F-female to N-male

75-ohm adapter

85039-60013

F-male to N-female

75-ohm adapter 

85039-60011

Typical type-F to type-N adapter 

characteristics

DC to 1 GHz 

RL 

38 dB

1 to 3 GHz 

RL 

32 dB

Содержание 8753ES

Страница 1: ...53ES S parameter vector network analyzer HP 8753ES Option 011 vector network analyzer without test set HP 8753ET Transmission reflection vector network analyzer For more information about these analyzers please see the following documents HP literature number HP 8753ET and 8753ES Network Analyzers Brochure 5968 5159E HP 8753ET and 8753ES Network Analyzers Configuration Guide 5968 5158E ...

Страница 2: ...contents Definitions and test conditions 3 System performance summaries 4 Specifications and characteristics 10 Measurement throughput summary 21 Options 21 Test set specifications for Option 011 22 Accessories 24 ...

Страница 3: ...ring the measure ment Measurement uncertainty Measurement uncertainty curves utilize a Root Sum Square RSS model for the contribution of random errors such as noise typical connector repeatabilities and test set switching this is combined with a worst case model for the contributions of dynamic accuracy and residual systematic errors Curves show the worst case magnitude and phase uncertainty for r...

Страница 4: ...0 kHz 1 3 GHz 1 3 GHz 3 GHz 3 GHz 6 GHz Directivity 55 dB 55 dB 51 dB 46 dB Source match 55 dB 51 dB 49 dB 43 dB Load match 55 dB 55 dB 51 dB 46 dB Reflection 0 001 dB 0 001 dB 0 005 dB 0 020 dB tracking 0 02 dB C 0 01 dB C 0 02 dB C 0 03 dB C Transmission 0 008 dB 0 006 dB 0 009 dB 0 021 dB tracking 0 02 dB C 0 01 dB C 0 02 dB C 0 03 dB C Uncorrected Directivity 20 dB 35 dB 30 dB 25 dB Source mat...

Страница 5: ...n 014 103 dB Reflection uncertainty Magnitude Transmission uncertainty Magnitude Measurement port characteristics Frequency range Corrected 30 kHz 300 kHz2 300 kHz 1 3 GHz 1 3 GHz 3 GHz 3 GHz 6 GHz Directivity 50 dB 50 dB 47 dB 40 dB Source match 49 dB 42 dB 36 dB 31 dB Load match 50 dB 50 dB 47 dB 40 dB Reflection 0 005 dB 0 009 dB 0 019 dB 0 070 dB tracking 0 02 dB C 0 01 dB C 0 02 dB C 0 03 dB ...

Страница 6: ...105 dB Option 014 103 dB Reflection uncertainty Magnitude Transmission uncertainty Magnitude Measurement port characteristics Frequency range Corrected 30 kHz 300 kHz2 300 kHz 1 3 GHz 1 3 GHz 3 GHz 3 GHz 6 GHz Directivity 49 dB 46 dB 44 dB 38 dB Source match 49 dB 44 dB 41 dB 37 dB Load match 49 dB 46 dB 44 dB 38 dB Reflection 0 010 dB 0 005 dB 0 007 dB 0 009 dB tracking 0 02 C 0 01 C 0 02 C 0 03 ...

Страница 7: ...0 kHz 1 3 GHz 1 3 GHz 3 GHz Directivity 48 dB 48 dB 43 dB Source match 47 dB 41 dB 35 dB Load match 48 dB 48 dB 43 dB Reflection 0 004 dB 0 010 dB 0 019 dB tracking 0 02 dB C 0 01 dB C 0 02 dB C Transmission 0 018 dB 0 016 dB 0 033 dB tracking 0 02 dB C 0 01 dB C 0 02 dB C Uncorrected2 30 kHz 300 kHz 300 kHz 1 3 GHz 1 3 GHz 3 GHz Directivity 20 dB 35 dB 30 dB Source match 16 dB 16 dB 16 dB Load ma...

Страница 8: ...Transmission uncertainty Magnitude Measurement port characteristics Data is shown for a Type F female reflection port and a Type F male transmission port Frequency range Corrected2 30 kHz 300 kHz 300 kHz 1 3 GHz 1 3 GHz 3 GHz Directivity 45 dB 45 dB 40 dB Source match 40 dB 40 dB 30 dB Load match 45 dB 45 dB 40 dB Reflection 0 060 dB 0 060 dB 0 024 dB tracking 0 02 dB C 0 01 dB C 0 02 dB C Transmi...

Страница 9: ...GHz 3 0 GHz 6 0 GHz Reflection measurements1 Directivity 50 dB 47 dB 40 dB Source match 42 dB 36 dB 31 dB Load match One port cal 24 dB 19 dB 16 dB Enhanced reflection cal 24 dB 19 dB 16 dB Reflection tracking 0 009 dB 0 019 dB 0 07 dB 0 01 dB C 0 02 dB C 0 03 dB C Transmission measurements2 Source match Enhanced response cal 42 dB 36 dB 31 dB Response only cal3 25 dB 20 dB 14 dB Transmission trac...

Страница 10: ...mpedance 50 Ω nominal Option 075 75 Ω nominal Frequency response2 5 300 kHz to 3 GHz 1 0 dB 3 GHz to 6 GHz 2 0 dB Internally generated harmonics Option 002 2nd harmonic3 15 dBc at 8 dBm 30 dBc at 0 dBm9 45 dBc at 15 dBm9 3rd harmonic4 30 dBc at 8 dBm 50 dBc at 0 dBm9 50 dBc at 15 dBm9 Harmonic measurement accuracy10 300 kHz to 3 GHz 1 5 dB 3 GHz to 6 GHz 3 dB Option 006 Harmonic measurement dynami...

Страница 11: ...0 dB rms Reference level Range 500 dB Resolution 0 001 dB Stability2 30 kHz to 3 GHz 0 02 dB C 3 GHz to 6 GHz 0 04 dB C Phase characteristics Dynamic accuracy 10 Hz IF BW Range 180 Display resolution 0 01 division Marker resolution3 0 01 Trace noise 5 dBm at test port ratio measurement 3 kHz BW 300 kHz to 3 GHz 0 038 rms 3 GHz to 6 GHz 0 070 rms Reference level Range 180 to 180 Resolution 0 01 Sta...

Страница 12: ...0 kHz to 3 GHz Option 006 30 kHz to 6 GHz Average noise level2 50 kHz to 3 GHz 90 dBm 3 kHz BW 50 kHz to 3 GHz 110 dBm 10 Hz BW 50 kHz to 3 GHz 120 dBm 10 Hz BW typical 3 to 6 GHz 85 dBm 3 kHz BW 3 to 6 GHz 105 dBm 10 Hz BW 3 to 6 GHz 115 dBm 10 Hz BW typical Maximum input level 0 dBm Damage level 20 dBm or 25 VDC Impedance 50 ohms nominal 300 kHz to 2 MHz 20 dB RL 2 MHz to 1 3 GHz 24 dB RL 1 3 GH...

Страница 13: ...ms Reference level Range 500 dB Resolution 0 001 dB Stability2 30 kHz to 3 GHz 0 02 dB C 3 GHz to 6 GHz 0 04 dB C Range 180 Display resolution 0 01 division Marker resolution5 0 01 Trace noise2 30 kHz to 3 GHz 0 038 rms 3 GHz to 6 GHz 0 070 rms 5 dBm at test port ratio measurement 3 kHz BW Reference level Range 180 to 180 Resolution 0 01 Stability 30 kHz to 3 GHz 0 05 C 3 GHz to 6 GHz 0 20 C Polar...

Страница 14: ...z to 6 GHz 114 dBm 10 Hz BW typical Maximum input level 10 dBm reflection port 0 dBm transmission port Damage level 26 dBm or 35 VDC Impedance 50 Ω nominal Frequency response5 300 kHz to 3 GHz 1 0 dB 3 GHz to 6 GHz 2 0 dB Harmonics Option 002 2nd harmonic2 15 dBc at 8 dBm 30 dBc at 0 dBm4 45 dBc at 15 dBm4 3rd harmonic3 30 dBc at 8 dBm 50 dBc at 0 dBm4 50 dBc at 15 dBm4 Harmonic measurement accura...

Страница 15: ... 010 dB rms Reference level Range 500 dB Resolution 0 001 dB Stability2 300 kHz to 3 GHz 0 02 dB 1 C 3 GHz to 6 GHz 0 04 dB 1 C Phase characteristics Dynamic accuracy 10 Hz IF BW Range 180 Display resolution 0 01 division Marker resolution3 0 01 Trace noise 0 dBm at transmission port or 5 dBm at reflection port ratio measurement 3 kHz BW 300 kHz to 3 GHz 0 038 rms 3 GHz to 6 GHz 0 070 rms Referenc...

Страница 16: ...an number of points 1 Range The maximum delay is limited to measuring no more than 180 of phase change within the minimum aper ture Range 1 2 x minimum aperture Accuracy The following graph shows group delay accuracy at 1 3 GHz with type N full two port calibration and 10 Hz IF bandwidth Insertion loss is assumed to be 2 dB and electrical length to be ten meters Source control Sweep limits Set sta...

Страница 17: ...lyzers TRL LRM calibration Compensates for directivity reflection and transmis sion frequency response and crosstalk in both the for ward and reverse directions Especially suitable for calibrating non coaxial environments such as in test fixtures TRL LRM is a special implementation of TRL LRM calibration modified for the three sampler receiver in the HP 8753ES Available on HP 8753ES analyzers Inte...

Страница 18: ... sequence 6 is titled AUTO it will be executed when power is turned on Disk drive Data instrument states user graphics data plots and test sequences can be stored on internal floppy disk in MS DOS or Hewlett Packard s standard LIF formats Data hardcopy Data plotting Hardcopy plots are automatically produced with HP GL compatible digital plotters The HP 8753ET ES pro vides Centronics RS 232C and GP...

Страница 19: ...timulus similar to a traditional time domain reflec tometer TDR stimulus waveform is used to measure low pass devices The frequency domain data should extend from DC extrapolated value to a higher value Low pass impulse This stimulus is also used to measure low pass devices Bandpass impulse The bandpass impulse stimulates a pulsed RF signal with an impulse envelope and is used to measure the time ...

Страница 20: ...tputs a TTL end of sweep signal It can also be programmed by the user in a test sequence to output a user defined TTL signal BNC f connector Limit test output LIMIT TEST This connector outputs a TTL signal of the limit test results Pass TTL high Fail TTL low BNC f connec tor Test port bias input BIAS CONNECT HP 8753ES only Maximum voltage 30 VDC Maximum current no degradation in RF specs 200 mA Ma...

Страница 21: ...ation1 310 380 415 658 Two port calibration2 618 757 829 1315 Time domain increase over uncorrected sweep time 3 Conversion 12 42 86 378 Gating 14 40 80 349 GP IB data transfer4 Internal binary 10 16 21 58 ASCII 35 112 214 831 IEEE 754 floating point format 32 bit 11 19 28 83 64 bit 13 26 42 141 Options Harmonic measurements Option 002 Measures amplifier 2nd and 3rd harmonics on a swept frequency ...

Страница 22: ...14 dB 2 0 MHz to 1 3 GHz 20 dB 17 dB 1 3 GHz to Fmax 16 dB Nominal insertion loss Input to test port 14 dB 0 5 dB GHz 19 5 dB 1 dB GHz Input to incident 18 dB 1 5 dB GHz 18 dB 1 5 dB GHz Port 1 2 to A B 6 5 dB 1 0 dB GHz 12 dB 0 5 dB GHz Test set switch repeatability 0 03 dB 0 01 dB3 Max operating level 20 dBm Damage level 30 dBm RF attenuator range 70 dB 10 dB steps DC bias range 30 VDC 200 mA4 5...

Страница 23: ... 1 5 dB 20 Source match1 300 kHz to 1 3 GHz 20 dB 1 3 GHz to 3 GHz 16 dB 3 GHz to 6 GHz 14 dB Normal insertion loss Input to port 1 2 300 kHz to 3 GHz 4 0 dB 0 8 dB GHz 3 GHz to 6 GHz 17 5 dB 0 8 dB GHz Input to R 300 kHz to 3 GHz 19 dB 0 5 dB GHz 3 GHz to 6 GHz 34 dB 0 5 dB GHz Port 1 2 to A B 16 dB Typical Isolation4 300 kHz to 3 GHz 100 dB 3 GHz to 6 GHz 90 dB Test port switch repeatability 0 0...

Страница 24: ... dB 2 to 3 GHz RL 46 dB 3 to 6 GHz RL 40 dB Typical adapter characteristics DC to 6 GHz RL 30 dB HP 85033D 3 5 mm calibration kit Contains a set of precision 3 5 mm standards to cali brate the HP 8753ES and 50 ohm test sets for the measurement of devices with precision 3 5 mm and SMA connectors Precision phase matched 7 mm to 3 5 mm adapters are included for accurate measure ments of non insertabl...

Страница 25: ...er kit Description Quantity HP Part Number 7 16 male to male adapter 1 11906 80015 7 16 female to female adapter 1 11906 80016 7 16 male to female adapter 2 11906 80017 HP 11906B 7 16 to 50 Ohm type N adapter kit Description Quantity HP Part Number Type N male to 7 16 male adapter 1 11906 80007 Type N female to 7 16 female adapter 1 11906 80008 Type N female to 7 16 male adapter 1 11906 80009 Type...

Страница 26: ...s These cables can be used with connector types other than 7 mm with the appropriate precision adapters Return loss 24 dB to 3 GHz 20 dB to 6 GHz Phase tracking 2 at 1 3 GHz HP 11857F type F test port return cables Type F test port cable set 75 ohm Includes one cable with type N male to type F male connectors and one cable with type N male to type F female connectors HP 11850C D three way power sp...

Страница 27: ...on 1250 1532 HP 11856A 75 ohm BNC accessory kit Includes HP part number Type N m to BNC f adapter 1250 1535 Type N m to BNC m adapter 1250 1533 Type N f to BNC m adapter 1250 1534 Type N f to BNC f adapter 1250 1536 BNC m short 1250 0929 BNC m termination 11652 60010 RF limiter Externally attaches to one or both ports of the analyz er Provides protection against potential high power transients fro...

Страница 28: ...re information about Hewlett Packard test and measure ment products applications services and for a current sales office listing visit our web site http www hp com go tmdir You can also contact one of the following centers and ask for a test and measurement sales representative United States Hewlett Packard Company Test and Measurement Call Center P O Box 4026 Englewood CO 80155 4026 1 800 452 484...

Отзывы: