45 

Network topology icons 

 

Represents a generic network device, such as a router, switch, or firewall. 

 

Represents a routing-capable device, such as a router or Layer 3 switch. 

 

Represents a generic switch, such as a Layer 2 or Layer 3 switch, or a router that 
supports Layer 2 forwarding and other Layer 2 features. 

 

Port numbering in examples 

The port numbers in this document are for illustration only and might be unavailable on your device. 

Содержание 5830 series

Страница 1: ...HP 5830 Switch Series Installation Guide Part number 5998 2058e Document version 6W102 20160513 ...

Страница 2: ...MATERIAL INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE Hewlett Packard shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing performance or use of this material The only warranties for HP products and services are set forth in the express warranty statements accompan...

Страница 3: ...ing the 96G model 96G TAA model switch 15 Grounding the switch 17 Grounding the switch with a grounding strip 18 Grounding an AC powered switch through the PE wire 18 Installing removing a fan tray 19 Selecting a fan tray 19 Installing a fan tray 20 Removing a fan tray 21 Installing removing a power supply 21 Installing a power supply 21 Removing a power supply 22 Connecting the power cord 24 Conn...

Страница 4: ...x A Technical specifications 46 Technical specifications 46 Panel views 47 48G model 48G TAA model panel views 47 96G model 96G TAA model panel views 48 Cooling system 49 Cooling system of the 48G model 48G TAA model 49 Cooling system of the 96G model 96G TAA model 51 Appendix B FRUs and compatibility matrixes 52 Hardware compatibility matrix 52 Hot swappable power supplies 189H52 76HHot swappable...

Страница 5: ...Read all of the safety instructions in the Compliance and Safety Guide supplied with your device before installation and operation This section provides general recommendations For more information see the Compliance and Safety Guide included with your device Turn off all the power and remove all the power cables before opening the chassis Unplug all power and external cables before moving the cha...

Страница 6: ...erent switch models see Table 10 in Appendix A Technical specifications Table 2 Dust concentration limit in the equipment room Substance Concentration limit particles m3 Dust particles 3 x 104 No visible dust on desk in three days NOTE Dust particle diameter 5 μm Table 3 Limits on harmful gases in the equipment room Gas Maximum concentration mg m3 SO2 0 2 H2S 0 06 NH3 0 05 Cl2 0 01 Rack mounting r...

Страница 7: ...air of cable management brackets and eight M4 countersunk screws 1 kit 5830AF 96G 5830AF 96G TAA 5185 8713 1 U long slide rail kit including one pair of slide rails one pair of guide rails and four M4 countersunk screws 1 kit 5830AF 48G 5830AF 48G TAA 5185 8684 2 U slide rail kit including one pair of slide rails one pair of guide rails and four M4 countersunk screws 1 kit 5830AF 96G 5830AF 96G TA...

Страница 8: ...9 DC power cord The power cord color code scheme is for illustration only The cable delivered for your country or region might use a different color scheme 1 650 W DC power supply 5185 8748 Removable cable tie 1 All power supplies 5185 8627 Console cable 1 All 5830AF switches 5185 8722 SFP SFP dust plug Optional All 5830AF switches ...

Страница 9: ...or any consequence Figure 1 Hardware installation flow Start Install to a specified position Install a power module Install a fan tray Ground the switch Connect the power cord Verify the installation Power on the switch Operating properly Power off the switch No Troubleshoot the switch Install an interface card Yes Yes Verify the installation Operating properly No Troubleshoot the switch Yes End N...

Страница 10: ...ll a rack see the rack installation guide Installing the switch in a 19 inch rack Mounting bracket and cable management bracket kits Table 5 Mounting bracket and cable management bracket kits Switch models Mounting brackets Cable management brackets Bracket view 48G model 48G TAA model One pair of 1U mounting brackets supplied with the switch N A See Figure 2 96G model 96G TAA model One pair of 2U...

Страница 11: ...le management bracket 2 Mounting bracket Rack mounting rail kit The switches come with a pair of chassis rails and a pair of slide rails For more information see Table 7 Figure 4 Chassis rail and slide rail kit for the 48G model 48G TAA model 1 Chassis rail 2 Slide rail ...

Страница 12: ...ying the mounting position Table 6 Mounting positions Mounting bracket position Installing the mounting brackets chassis rails and grounding cable Installing the switch Rear mounting near the power supplies Front mounting near the network ports See Installing the mounting brackets chassis rails and grounding cable for the 48G model 48G TAA model See Installing the mounting brackets chassis rails a...

Страница 13: ...ition near the power supplies The switch also has one primary grounding point with a grounding sign and one auxiliary grounding point Use the primary grounding point in most situations If the primary grounding point fails or is not suitable for the installation site use the auxiliary grounding point Figure 7 Identifying the mounting and grounding positions 1 Rear mounting position 2 Primary ground...

Страница 14: ...e grounding points you must connect the grounding cable to the grounding point before you mount the switch in the rack To connect the grounding cable to a chassis grounding point 1 Select a grounding point for example the primary grounding point 2 Remove the grounding screws from the primary grounding point You can use the screws for connecting to the primary grounding point or the auxiliary groun...

Страница 15: ...mary grounding point in most situations If the primary grounding point fails or is not suitable for the installation site use the auxiliary grounding point Figure 10 Identifying the mounting and grounding positions 1 Rear mounting position 2 Primary grounding point 3 Auxiliary grounding point 4 Front mounting position Attaching the mounting brackets and chassis rails to the switch chassis Use the ...

Страница 16: ... grounding point before you mount the switch in the rack To connect the grounding cable to a chassis grounding point 1 Choose a grounding point for example the primary grounding point 2 Unpack the grounding cable and the grounding screws You can use the cable and screws for connecting to the primary grounding point or the auxiliary grounding point 3 Align the two hole grounding lug at one end of t...

Страница 17: ...ide rail with the cage nuts in the rack post on one side and use screws user supplied to fix the slide rail to the rack as shown in Figure 13 4 Repeat the preceding step to attach the other slide rail to the rack post on the other side Keep the two slide rails at the same height so the slide rails can fit into the chassis rails Figure 13 Installing the slide rails Mounting the switch on the rack r...

Страница 18: ...de rails 5 Supporting the bottom of the switch align the chassis rails with the slide rails on the rack posts as shown in Figure 14 Work with another person to slide the chassis rails along the slide rails until the mounting brackets flush with the rack posts 6 Use appropriate screws to fix the mounting brackets to the rack as shown in Figure 15 Make sure the front ends of the slide rails reach ou...

Страница 19: ...ser supplied in the mounting holes in the rack posts 3 Align the screw holes in one slide rail with the cage nuts in the rack post on one side and use screws user supplied to fix the slide rail to the rack as shown in Figure 16 4 Repeat the preceding steps to attach the other slide rail to the rack post on the other side Keep the two slide rails at the same height so the slide rails can fix into t...

Страница 20: ...stall cage nuts user supplied to the front rack posts and make sure they are at the same level as the slide rails 5 Supporting the bottom of the switch align the chassis rails with the slide rails on the rack posts as shown in Figure 17 Work with another person to slide the chassis rails along the slide rails until the mounting brackets flush with the rack posts 6 Use appropriate screws to fix the...

Страница 21: ...17 Mounting the switch in the rack 1 Figure 18 Mounting the switch in the rack 2 Grounding the switch WARNING Correctly connecting the switch grounding cable is crucial to lightning protection and EMI protection ...

Страница 22: ...ing the switch with a grounding strip 1 Attach the two hole grounding lug at one end of the grounding cable to a grounding point on the switch chassis 48G model and 48G TAA model see Connecting the grounding cable to the switch chassis 96G model and 96G TAA model See Connecting the grounding cable to the switch chassis 2 Connect the ring terminal at the other end of the grounding cable to a ground...

Страница 23: ... be damaged Selecting a fan tray The switches provide two types of fan trays with different airflow directions from power side to port side and from port side to power side Before you install a fan tray check the airflow direction labeled on the fan tray and make sure the airflow of the chassis is appropriate to the installation site When the switch is started up the system records the airflow dir...

Страница 24: ...ails into the slot until the fan tray seats in the slot and has a firm contact with the backplane see callout 1 in Figure 21 or Figure 22 To prevent damage to the fan tray or the connectors on the backplane insert the fan tray gently If you encounter resistance while inserting the fan tray pull out the fan tray and insert it again 5 Fasten the captive screw on the fan tray with a Philips screwdriv...

Страница 25: ...he switches see Appendix B FRUs and compatibility matrixes Installing a power supply 1 Wear an ESD wrist strap and make sure it makes good skin contact and is reliably grounded 2 Remove the power filler module from the power supply slot 3 Unpack the power supply and check that the power supply model is correct 4 Correctly orient the power supply with the power supply slot see Figure 23 and Figure ...

Страница 26: ...st strap and make sure it makes good skin contact and is reliably grounded 2 Remove the power cord from the power supply If the power supply is AC powered directly unplug the power cord If the power supply is DC powered squeeze the tabs on the power cord connector with your thumb and forefinger and pull the connector out as shown in Figure 25 3 Hold the handle on the power supply with one hand piv...

Страница 27: ...the tabs on the power cord connector with your thumb and forefinger 2 Pull the power cord connector out Figure 26 Removing the power supply for the 48G model 48G TAA model 1 Pivot the latch to the right with your thumb 2 Pull the power supply out 1 2 ...

Страница 28: ...cord supplied with the power supply into the AC input power receptacle of the power supply 2 Use a cable tie to secure the power cord to the handle of the power supply as shown in Figure 28 3 Connect the other end of the power cord to an AC power outlet Figure 28 Connecting the 650W AC power supply JC680A 1 Cable tie 2 Tighten the cable tie to secure the power cord to the handle of the power suppl...

Страница 29: ...s of the wires to the DC power source wiring terminals with the negative wire or L to the negative terminal and the positive wire or M N to the positive terminal Figure 29 Connecting the 650W DC power supply JC681A Installing removing an interface card CAUTION Do not touch the surface mounted components directly with your hands Do not use excessive force during the operation Each of the 48G model ...

Страница 30: ...t 2 Tighten the captive screws Removing an interface card 1 Wear an ESD wrist strap and make sure it makes good skin contact and is reliably grounded 2 Use a Phillips screwdriver to loosen the captive screws at both sides of the interface card completely 3 Pull the interface card along the guide rails until it completely comes out of the switch chassis 4 If no new card is to be installed install t...

Страница 31: ...n the switch verify the following items are in place There is enough space for heat dissipation around the switch and the rack is stable The grounding cable is securely connected The correct power source is used The power cords are properly connected ...

Страница 32: ...for configuration environment setup Connecting the console cable Console cable A console cable is an 8 core shielded cable with a crimped RJ 45 connector at one end for connecting to the console port of the switch and a DB 9 female connector at the other end for connecting to the serial port on the console terminal Figure 34 Console cable Connection procedure To connect a terminal device to the sw...

Страница 33: ...switch disconnect the DB 9 connector of the console cable from the PC after disconnecting the RJ 45 connector from the switch Setting terminal parameters To configure and manage the switch you must run a terminal emulator program on the console terminal for example a PC This section uses Windows XP HyperTerminal as an example The following are the required terminal settings Bits per second 9600 Da...

Страница 34: ...e serial port to be used from the Connect using list and click OK Figure 36 Setting the serial port used by the HyperTerminal connection 4 Set Bits per second to 9600 Data bits to 8 Parity to None Stop bits to 1 and Flow control to None and click OK ...

Страница 35: ...31 Figure 37 Setting the serial port parameters 5 Select File Properties in the HyperTerminal window Figure 38 HyperTerminal window 6 On the Settings tab set the emulation to VT100 and click OK ...

Страница 36: ...e meets the requirement of the switch The console cable is properly connected the terminal or PC used for configuration has started and the configuration parameters have been set Powering on the switch Power on the switch for example an 5830AF 48G switch and you can see the following information System is starting Booting Normal Extend BootWare The Extend BootWare is self decompressing Done HP A58...

Страница 37: ...to enter extended boot menu Starting to get the main application file flash main bin The main application file is self decompressing Done The oam application file is self decompressing Done System application is starting User interface aux0 is available Press ENTER to get started Press Enter at the prompt When the prompt HP appears you can configure the switch For more information about the config...

Страница 38: ...and high availability scalability and manageability IRF fabric setup flowchart Figure 40 IRF fabric setup flowchart To set up an IRF fabric Start Plan IRF fabric setup Install IRF member switches Connect the grounding cable and power cords Power on the switches Configure basic IRF settings Connect the physical IRF ports Slave switches reboot and the IRF fabric is automatically established End ...

Страница 39: ...hoose the switch models and identify the number of required IRF member switches depending on the user density and upstream bandwidth requirements The switching capacity of an IRF fabric equals the total switching capacities of all member switches As your business grows you can plug a switch into an IRF fabric to increase the switching capacity without any topology change or replacement Plan the in...

Страница 40: ...ces for the connections between IRF member switches Each IRF member switch has two IRF ports IRF port 1 and IRF port 2 An IRF port goes up when you bind the first member physical port to it When connecting IRF member switches you must connect the physical ports of IRF port 1 on one switch to the physical ports of IRF port 2 on its neighbor switch The switches can provide 10 GE IRF connections thro...

Страница 41: ... TAA model 10 fixed SFP ports on the front panel Planning the cabling scheme Use SFP cables or SFP transceiver modules and fibers to connect the IRF member switches If the IRF member switches are far away from one another choose the SFP transceiver modules with optical fibers If the IRF member switches are all in one equipment room choose SFP cables Table 21 and Table 22 list the SFP transceivers ...

Страница 42: ... as connected in the rack Figure 43 Connecting the switches in one rack Figure 44 IRF fabric topology Connecting the IRF member switches in a ToR solution You can install IRF member switches in different racks side by side to deploy a ToR solution Figure 45 shows an example for connecting four top of rack IRF member switches by using SFP transceiver modules and optical fibers The topology is the s...

Страница 43: ...IRF ports Use SFP cables or SFP transceiver modules and fibers to connect the IRF member switches as planned NOTE Wear an ESD wrist strap when you connect SFP cables or SFP transceiver modules and fibers For how to connect them see SFP SFP XFP Transceiver Modules Installation Guide Accessing the IRF fabric to verify the configuration To verify the basic functionality of the IRF fabric after you fi...

Страница 44: ...irf topology NOTE To avoid IP address collision and network problems configure at least one MAD mechanism to detect the presence of multiple identical IRF fabrics and handle collisions For more information about MAD detection see HP 5830 Switch Series IRF Configuration Guide ...

Страница 45: ... has failed Contact HP technical support to replace the old power supply Fan failure When a fan tray is working properly its status LED is green If the LED is red or off verify the following items 1 The switch and the power supplies are working properly 2 The air intakes and exhaust vents of the chassis are not blocked If the problem persists contact HP for help Configuration terminal problems If ...

Страница 46: ...42 Data bits 8 Parity None Stop bits 1 Flow control None Emulation VT100 ...

Страница 47: ... wwalerts After registering you will receive email notification of product enhancements new driver versions firmware updates and other product resources Related information Documents To find related documents browse to the Manuals page of the HP Business Support Center website http www hp com support manuals For related documentation navigate to the Networking section and select a networking categ...

Страница 48: ...parated by vertical bars from which you select one choice multiple choices or none 1 n The argument or keyword and argument combination before the ampersand sign can be entered 1 to n times A line that starts with a pound sign is comments GUI conventions Convention Description Boldface Window names button names field names and menu items are in bold text For example the New User window appears cli...

Страница 49: ...ing capable device such as a router or Layer 3 switch Represents a generic switch such as a Layer 2 or Layer 3 switch or a router that supports Layer 2 forwarding and other Layer 2 features Port numbering in examples The port numbers in this document are for illustration only and might be unavailable on your device ...

Страница 50: ...the rear panel 1 on the rear panel Power supply slots 2 on the rear panel 2 on the rear panel AC input rated voltage 100 VAC to 240 VAC 50 Hz or 60 Hz 100 VAC to 240 VAC 50 Hz or 60 Hz DC input rated voltage 40 VDC to 60 VDC 40 VDC to 60 VDC Minimum power consumption 91 2 W 283 5 W Maximum power consumption 128 6 W 380 W Fan power consumption 0 9 W to 8 4 W 4 4 W to 75 5 W Chassis leakage current ...

Страница 51: ...w fan tray JC693A JC695A HP A5830AF 96G back power side to front port side airflow Fan Tray Back to front airflow fan tray JC695A JC696A HP A5830AF 96G front port side to back power side airflow Fan Tray Front to back airflow fan tray JC696A Panel views This section describes the chassis panel views of the switches 48G model 48G TAA model panel views Figure 46 Front panel 1 10 100 1000Base T auto ...

Страница 52: ...o 650W AC power supplies JC680A one back to front airflow fan tray JC692A and one LSPM2SP2P JD368B expansion interface card are installed Figure 48 Left side panel 1 Primary grounding point 2 Auxiliary grounding point 96G model 96G TAA model panel views Figure 49 Front panel 1 Management Ethernet port 2 Console port 3 10 100 1000Base T auto sensing Ethernet port 4 10 100 1000Base T Ethernet port L...

Страница 53: ...power supplies To guarantee the performance of this cooling system consider the ventilation design for the installation site when you choose a fan tray assembly and plan the installation site for the switch Cooling system of the 48G model 48G TAA model When a back to front airflow fan tray JC692A is used ambient air flows in through the air vents in the fan tray panel and the power supply panels c...

Страница 54: ...vents 2 Fan tray air vents 3 Port side air vents Figure 53 Airflow through the switch chassis with the front to back airflow fan tray JC693A 1 Power supply air vents 2 Fan tray air vents 3 Port side air vents IMPORTANT The chassis and the power supplies use separate air aisles Make sure both aisles are not blocked ...

Страница 55: ...used ambient air flows in through the air vents in the port side panel and the power supply panels circulates through the chassis and the power supplies and exhausts through the air vents in the fan tray panel as shown in Figure 55 Figure 54 Airflow through the switch chassis with the back to front airflow fan tray JC695A 1 Power supply air vents 2 Fan tray air vents 3 Port side air vents Figure 5...

Страница 56: ... Fan Tray JC696A No Yes Interface card options LSPM2SP2P JD368B Yes No Hot swappable power supplies The switches have two power supply slots You can install one power supply or for redundancy two power supplies in Table 13 for these switches All these power supplies are hot swappable Table 13 Power supply specifications and the compatibility with the switches Power supply Specifications Switch cha...

Страница 57: ... JC693A User Guide Front to back airflow fan tray JC693A for the 48G model 48G TAA model Fans Four 40 40 28 mm 1 57 1 57 1 1 in fans Max fan speed 9500 R P M Max airflow 40 CFM Airflow direction Front to back fans draw air from the network port side to the power supply side Max power consumption 8 42 W Min power consumption 0 87 W Documentation reference HP A5830AF 48G Fan Trays JC692A JC693A User...

Страница 58: ... consumption 4 4 W Documentation reference HP A5830AF 96G Fan Trays JC695A JC696A User Guide Interface cards Each of the 48G model and 48G TAA model switches has one expansion interface card slot Table 15 describes the interface card available for switches Table 15 48G model 48G TAA model interface card Card model Name Description LSPM2SP2P JD368B 2 port 10 GE SFP optical interface card Provides t...

Страница 59: ...port You can connect this port to a PC or management station for loading and debugging system software or remote management Table 17 Management Ethernet port specifications Item Specification Connector type RJ 45 Connector quantity 1 Port transmission rate 10 100 1000 Mbps half full duplex Transmission medium and max transmission distance 100 m 328 08 ft over category 5 twisted pair cable Function...

Страница 60: ...ription Central wavelength nm Fiber diameter μm Multi mode fiber modal bandwidth MHz km Max transmission distance JD118B HP X120 1G SFP LC SX Transceiver 850 50 125 500 550 m 1804 46 ft 400 500 m 1640 42 ft 62 5 125 200 275 m 902 23 ft 160 220 m 721 78 ft JD119B HP X120 1G SFP LC LX Transceiver 1310 9 125 N A 10 km 6 21 miles 50 125 500 550 m 1804 46 ft 400 550 m 1804 46 ft 62 5 125 500 550 m 1804...

Страница 61: ...0 miles JD110A HP X170 1G SFP LC LH70 1570 Transceiver 1570 9 125 N A 70 km 43 50 miles JD111A HP X170 1G SFP LC LH70 1590 Transceiver 1590 9 125 N A 70 km 43 50 miles JD112A HP X170 1G SFP LC LH70 1610 Transceiver 1610 9 125 N A 70 km 43 50 miles IMPORTANT You must use the HP X120 1G SFP LC BX 10 U Transceiver JD098B and the HP X120 1G SFP LC BX 10 D Transceiver JD099B in pairs Table 20 100 Mbps ...

Страница 62: ...rnet ports numbered 47 and 48 on an 48G model or 48G TAA model switch forms two combo interfaces Ports 49 and 47 form one combo interface and ports 50 and 48 form another Only one port in a combo interface can work at a time SFP port Every switch has SFP ports and you can plug the SFP transceiver modules SFP transceiver modules and SFP cables in Table 19 Table 21 or Table 22 into the SFP ports as ...

Страница 63: ...84 ft JG081C HP X240 10G SFP SFP 5m DA Cable 5 m 16 40 ft JC784C HP X240 10G SFP SFP 7m Direct Attach Copper Cable 7 m 22 97 ft For the SFP transceiver module specifications see HP A Series Switches Transceiver Modules User Guide NOTE To guarantee the functionality of the SFP ports use only HP SFP transceiver modules The SFP and SFP transceiver modules available for this switch series are subject ...

Страница 64: ...on SYS Flashing green The switch has started up properly Flashing red An alarm is generated Off The switch is powered off 10 100 1000Base T Ethernet port LED Each 10 100 1000Base T auto sensing Ethernet port has a status LED to show port operating status and activities Table 25 10 100 1000Base T auto sensing Ethernet port LED description Port LED status Description Steady green The port is operati...

Страница 65: ...data Off No link is present on the port Management Ethernet port LEDs The switches have two management Ethernet port LEDs LINK and ACT Table 28 Management Ethernet port LEDs description LED mark Status Description LINK Off The management Ethernet port is not connected Steady green The management Ethernet port is operating at 10 100 1000 Mbps ACT Off The management Ethernet port is not receiving or...

Страница 66: ...9H52 Hot swappable fan trays 310H53 Hot swappable power supplies 311H52 I Installation accessories 312H3 Installation tools 313H2 Installing the switch in a 19 inch rack 314H6 Installing removing a fan tray 315H19 Installing removing a power supply 316H21 Installing removing an interface card 317H25 Interface cards 318H54 IRF fabric setup flowchart 319H34 L LEDs 320H60 O Overview 321H1 P Panel vie...