16
4.
Grasp the handle of the power supply with one hand and pull the module part way out. Support
the module bottom with the other hand, and pull the power supply slowly along the guide rails out
of the slot.
5.
Place the removed power supply in an antistatic bag.
Figure 20
Removing a PSR150-A1 power supply
Connecting the power cord
CAUTION:
•
Provide a circuit breaker for each power cord.
•
Before connecting the power cord, make sure the circuit breaker on the power cord is turned off.
Table 5
Power cord connection procedures at a glance
Switch model
Available power source
Connection procedure
reference
•
HP 5130-24G-4SFP+ EI
•
HP 5130-24G-2SFP+-2XGT EI
•
HP 5130-24G-4SFP+ EI BR
AC power source
Connecting the switch to
an AC power source
•
HP 5130-48G-4SFP+ EI
•
HP 5130-24G-SFP-4SFP+ EI
•
HP 5130-48G-2SFP+-2XGT EI
•
HP 5130-48G-4SFP+ EI BR
AC power source
Connecting the switch to
an AC power source
–48 V DC power source in the
equipment room
Connecting the switch to a
–48 VDC power source
RPS
Recommended HP RPS models:
A-RPS800 (JD183A ) and
A-RPS1600 (JG136A)
Connecting the switch to
an RPS
•
HP 5130-24G-PoE+-4SFP+ (370W) EI
•
HP 5130-48G-PoE+-4SFP+ (370W) EI
AC power source
Connecting the switch to
an AC power source
1
2
1