Figure 4 Single Initiator to Single Target Zoning with Fan-In and Fan-Out
Non-Compliant Zoning Examples
In the following example, the zoning rule of one initiator zoned to one target is not respected, as
shown in
Figure 5 (page 13)
.
Figure 5 Non-Compliant Zoning
Setting Up and Zoning the Fabric