381
[Switch-line-vty0-15] authentication-mode scheme
[Switch-line-vty0-15] quit
# Create a local device management user
client001
.
[Switch] local-user client001 class manage
# Set the password to
aabbcc
in plain text for the local user
client001
.
[Switch-luser-manage-client001] password simple aabbcc
# Authorize the local user
client001
to use the
SSH
service.
[Switch-luser-manage-client001] service-type ssh
# Assign the user role
network-admin
to the local user
client001
.
[Switch-luser-manage-client001] authorization-attribute user-role network-admin
[Switch-luser-manage-client001] quit
# Create an SSH user
client001
. Specify the service type as
stelnet
and the authentication
method as
password
for the user.
[Switch] ssh user client001 service-type stelnet authentication-type password
2.
Establish a connection to the Stelnet server:
There are different types of Stelnet client software, including PuTTY and OpenSSH. This
example uses an Stelnet client that runs PuTTY version 0.58.
To establish a connection to the Stelnet server:
a.
Launch PuTTY.exe to enter the interface shown in
b.
In the
Host Name (or IP address)
field, enter the IP address
192.168.1.40
of the Stelnet
server.
Figure 100 Specifying the host name (or IP address)
c.
Click
Open
to connect to the server.
Содержание 10500 series
Страница 326: ...312 No duration limit for this SA ...