3.2.2 Mounting Inverter
Install the inverter on the wall using the provided wall-mounting bracket and expansion plug sets.
Procedure
Step 1
Step 2
Position the bracket against the
wall and mark the 4 drilling hole
locations.
Drill holes with a driller, make
sure the holes are deep enough
(at least 60 mm).
1
75mm 75mm
65mm
2
Step 3
Step 4
Place the expansion tubes in
the holes, and tighten them.
Then install the wall bracket
with the expansion screws.
Please confirm that the bracket
is firmly attached to the
mounting surface.
3
4
Step 5
Mount the inverter on the
bracket.
5
3.3 Electrical Wiring Connection
3.3.1 Grounding Connection
All non-current carrying metal parts and device enclosures in the PV power system should be grounded.
There is an additional grounding terminal located at bottom right of the inverter, connect to a nearby
grounding point.
Procedure
Step 1
Step 2
Prepare the cable and OT/DT
terminal.
Use the screw from the
accessory box. Then fasten the
cable with a screwdriver.
2
1
M4
1.2 N·m
L=H+(2-3)mm
mm²
S
H
L