Open Energy for All
USER MANUAL
HYT-5.0HV-EUG1
HYT-6.0HV-EUG1
HYT-8.0HV-EUG1
HYT-10.0HV-EUG1
HYT-12.0HV-EUG1
Region: Global REV1.0
hoymiles.com
Страница 1: ...Open Energy for All USER MANUAL HYT 5 0HV EUG1 HYT 6 0HV EUG1 HYT 8 0HV EUG1 HYT 10 0HV EUG1 HYT 12 0HV EUG1 Region Global REV1 0 hoymiles com...
Страница 2: ...ng Inverter 15 3 3 Electrical Wiring Connection 15 3 3 1 Grounding Connection 15 3 3 2 PV Wiring Connection 16 3 3 3 Battery Wiring Connection 17 3 3 4 AC Wiring Connection 18 3 3 4 1 Grid Connection...
Страница 3: ...n death or serious injury Indicates a hazard with a low level of risk that if not avoided can result in minor or moderate injury Indicates a situation that if not avoided can result in property damage...
Страница 4: ...ould be taken Please consider the actual conditions on site when performing operations Any damage caused by a violation of the safety instructions in this manual shall not be the responsibility of Hoy...
Страница 5: ...s should be grounded for safety reasons Ensure that existing wiring is in good condition and no wire is undersized Do not disassemble any parts of inverter which are not mentioned in installation Auth...
Страница 6: ...ystem s performance over time offering superior energy production H I J K A B C D E F G The image shown here is for reference only The actual product received may differ Object Description A DC Switch...
Страница 7: ...circle LEDs off No BMS communication RUN Off Inverter is not operating Blink 1 Inverter is booting Blink 2 Inverter is in bypass mode On Inverter is operating PV Off PV voltage is low Blink 1 PV powe...
Страница 8: ...m charge power the excess solar energy is fed back into the grid or limited if necessary At night the battery discharge for the loads first and once the battery power is insufficient the grid supplies...
Страница 9: ...y can be forced to charge from the grid during the preset charge time For instance the battery could be charged or discharged according to valley or peak electricity price Power flow of back up mode B...
Страница 10: ...ell as for self consumption of solar energy It can either form a DC coupled system for a new installation or an AC coupled system to retrofit existing installations This diagram is a simplified system...
Страница 11: ...ds on Loads Main Breaker 30 mA RCD HYT 6 0HV EUG1 25A 600V DC Breaker 16A 230V AC Breaker 25A 230V AC Breaker HYT 8 0HV EUG1 40A 600V DC Breaker 20A 230V AC Breaker 32A 230V AC Breaker HYT 10 0HV EUG1...
Страница 12: ...25A 600V DC Breaker 16A 230V AC Breaker 25A 230V AC Breaker HYT 8 0HV EUG1 25A 600V DC Breaker 20A 230V AC Breaker 32A 230V AC Breaker HYT 10 0HV EUG1 40A 600V DC Breaker 25A 230V AC Breaker 32A 230V...
Страница 13: ...With the addition of the hybrid inverter existing PV system can be retrofitted to be a PV ESS allowing more self consumption energy and more backup energy The detailed wiring of your system depends on...
Страница 14: ...anual 2022 Hoymiles Power Electronics Inc All rights reserved 13 3 Installation Instruction 3 1 Packing List Please ensure that none of the components listed below are missing or damaged upon receipt...
Страница 15: ...shelter from direct sunlight or bad weather such as snow rain or lightning 2 The inverter should be installed on a solid surface which is suitable for the inverter s dimensions and weight 3 The invert...
Страница 16: ...holes and tighten them Then install the wall bracket with the expansion screws Please confirm that the bracket is firmly attached to the mounting surface 3 4 Step 5 Mount the inverter on the bracket...
Страница 17: ...of an incompatible terminal shall not be covered by the warranty Please make sure the connectors are correct not the battery connectors as they look similar NOTICE Procedure Step 1 Unscrew the PV con...
Страница 18: ...ick if it is plugged in correctly 3 2 1 3 BAT BAT 4 Click 4 3 3 3 Battery Wiring Connection This section mainly describes the cable connections on the inverter side Refer to the instructions supplied...
Страница 19: ...r electrical connections are completed Procedure Step 1 Thread the AC cable of appropriate length through the waterproof terminal Remove the cable jacket by 20 25 mm and strip the wire insulation by 7...
Страница 20: ...sure all requirements listed below are followed Use the Grid Connector from the accessory box Damage to the device due to the use of an incompatible connector shall not be covered by the warranty An i...
Страница 21: ...port on the communication interfaces are as follows Label Description Meter 485A 485B For the Smart Meter BMS CANH CANL 485A 485B For Li ion battery communication via CAN or RS485 DRM D1 5 D2 6 D3 7...
Страница 22: ...the parts in sequence 1 2 3 2 Step 3 Strip the insulation layer of the communication cable with an ethernet wire stripper and lead the corresponding signal cables out Insert the stripped communicatio...
Страница 23: ...he inverter via RS485 communications One smart meter can be used with only one HYT HV inverter Three CTs must be used for one smart meter and must be connected on the same phase with the smart meter p...
Страница 24: ...Step 1 Peel the stickers off from the communication port 1 Step 2 Unscrew the communication box counterclockwise Disassemble the parts in sequence 1 2 3 2 Step 3 Strip the insulation layer of the com...
Страница 25: ...Connection There is an integrated DI IN IN as the dry contact input to the bypass contactor of the inverter The connection method is the same as that described in Chapter 3 3 5 3 Wiring the No 1 and N...
Страница 26: ...parallel function is in developing and could be realized through OTA For more information please contact Hoymiles technical support team 3 3 6 DTS Connection DTS WIFI G1 and DTS 4G G1 Procedure Steps...
Страница 27: ...for details Indicator Status Description RUN ON DTS is powered on OFF DTS is not powered on COM ON Proper communication with the inverter OFF Improper communication with the inverter NET ON Proper com...
Страница 28: ...een the mobile phone and DTS Configure the parameters in Storage Toolkit and Network Config referring to 3 4 2 S Miles Cloud APP Then use the System Self test function to detect if there is a problem...
Страница 29: ...ange 3 If the alarm persists please contact Hoymiles technical support team Grid Underfrequency The grid frequency is lower than the permissible range No Grid The inverter detects that there is no gri...
Страница 30: ...If the alarm persists contact Hoymiles technical support team EPS Load Overpower The EPS load power is higher than the permissible range 1 Reduce the power of EPS loads or remove some EPS loads The in...
Страница 31: ...MS Try to restart the battery If the fault persists contact the battery manufacturer BMS Battery Fault The inverter detects that there is a battery fault from BMS Try to restart the battery If the fau...
Страница 32: ...1 2 Max PV Input Current A 14 14 14 14 14 14 14 28 14 28 Short circuit Current of PV Input A 17 17 17 17 17 17 17 34 17 34 AC Input and Output On grid Nominal Output Apparent Power VA 5000 6000 8000 1...
Страница 33: ...Integrated AC Short Current Protection Integrated AC Overvoltage and Undervoltage Protection Integrated Surge Protection DC Type II AC Type III General Dimension W H D mm 502 486 202 Weight kg 26 Moun...
Страница 34: ...c All rights reserved 33 6 Contact Information S Miles Installer S Miles Enduser China No 18 Kangjing Road Hangzhou China 86 571 2805 6101 General inquiry info hoymiles com Technical support service h...