23
ALARMS AND WARNING MESSAGES
Information about opened door, low battery, problem in making
fire and signal loss are shown in the lower part of the display.
Po1
- first position. This phase begins when the fire chamber door is opened and
closed and ends when the starting temperature
T
start
is reached. The starting
temperature depends on the program that is set-up.
Po2
- second position. The second phase begins when the starting temperature
T
start
is reached and lasts at least 15 minutes after closing the door. The
maximum temperature
T
max
is reached in this phase.
Po3
- third position. This is the phase of active burning.
Po4
- fourth position. Phase of active burning where the air flap lets the smallest
amount of air in the combustion chamber.
Po5 -
fifth position. Phase of glowing coals without access of combustion air.
The air flap is fully closed.
Po0
- position zero – inactive phase where the air flap is closed.
The temperature in the combustion chamber is below 50°C.
Opened door
- informs that the fire chamber door is open.
Low battery
- red symbol indicates low battery in the display unit.
Please replace the batteries.
Problem in making fire
- if the temperature in the combustion chamber
reaches 50°C but doesn’t reach the starting temperature
T
start
in 15
minutes, red symbol appears followed by an acoustic signal. The air flap
remains open. If the temperature
T
start
is not reached in another 30
minutes and the temperature is below 50°C, the air flap closes completely.
Signal loss -
red symbol indicates a signal loss between the control unit
and the display. Follow “troubleshooting” on the next page.
EN