19
HIGH TEMPERATURE SENSOR INSTALLATION
Screw the high temperature sensor into the designed
opening on the fireplace insert or the stove doors.
Minimal lenght for correct measurment
is 20mm / 0.8 in at its end
(H)
.
The temperature sensor must be installed in the combustion chamber or in
the connection to the chimney. For proper functionality, the sensor can’t be
installed after an accumulation mass.
AIR INLET FLAP INSTALLATION
Connect the air inlet flap by alu flexible pipe (not included) with the fireplace
insert or stove doors. The connection between the air inlet flap and the product
must be tight.
When installing into closed-in build, the air inlet flap must be placed
outside the environment with high temperature. The heat resistence of the air
inlet flap is max 50°C / 122°F.
CONTROL UNIT CONNECTION
Connect all the components and power supply adapter to the control unit.
Then plug the power supply adapter into a socket.
For complete instruction
how to set-up the control
unit follow the instruction
stated in the chapter
„SET-UP“
1
1
1
2
2
2
min.
20 mm
H
EN