Troubleshooting
(Note:
All
wire
colors
are
subject
to
change)
Problem
Possible
Cause
Possible
Solution
Ice
Flaker
will
not
run
1.
Unplugged
or
defective
Photo
Eye(s).
1.
Ensure
Molex
plugs
are
properly
and
securely
connected.
Place
a
wire
jumper
between
terminals
#10
(blue)
and
#11(black)
at
the
Level
Control
Relay
(LC1).
If
Ice
Flaker
starts,
Photo
Eyes
may
be
defective
and
need
to
be
replaced.
2.
Defective
Level
Control
Relay
(LC1).
2.
Place
a
wire
jumper
between
terminals
#5
(red)
and
#6
(red)
at
the
Level
Control
Relay
(LC1).
If
Ice
Flaker
starts,
Level
Control
Relay
(LC1)
may
be
defective
and
need
to
be
replaced.
3.
No
control
power
from
Transformer
(T1).
3.
Check
voltage
across
Term
1
(purple)
and
Term
2
(yellow/orange)
at
Control
Module
(CM).
If
24
VAC
not
present,
Transformer
(T1)
may
be
defective
and
need
to
be
replaced.
4.
Open
switch
or
loose
wiring.
4.
Place
a
wire
jumper
between
Term
2
(yellow/orange)
and
Term
3
(red)
at
Control
Module
(CM).
If
Ice
Flaker
starts,
trace
voltage
from
Term
3.
Check
all
wire
terminals
and
tighten
as
necessary.
5.
Defective
Control
Module
(CM).
5.
Place
a
wire
jumper
between
Term
2
(yellow/orange)
and
Term
3
(red)
at
Control
Module
(CM).
If
Ice
Flaker
does
not
start,
Control
Module
(CM)
may
be
defective
and
need
to
be
replaced.
Ice
Flaker
does
not
shut
down
when
Ice
Bin
is
full
1.
Defective
Emitter
Photo
Eye.
1.
Unplug
Emitter
Photo
Eye
and
wait
longer
than
Off
‐
Delay
setting.
If
Ice
Flaker
stops,
Emitter
Photo
Eye
may
be
defective
and
need
to
be
replaced.
2.
Defective
Receiver
Photo
Eye.
2.
Unplug
Receiver
Photo
Eye
and
wait
longer
than
Off
‐
Delay
setting.
If
Ice
Flaker
stops,
Receiver
Photo
Eye
may
be
defective
and
need
to
be
replaced.
3.
Level
Control
Relay
(LC1)
is
jumped
out.
3.
Check
for
a
wire
jumper
between
terminals
#5
(red)
and
#6
(blue)
at
Level
Control
Relay
(LC1).
If
present
remove
wire
jumper.
4.
Defective
Control
Module
(CM).
4.
Remove
wire
from
Term
3
(red)
at
Control
Module
(CM)
and
wait
longer
than
Off
‐
Delay
setting.
If
Ice
Flaker
does
not
stop,
Control
Module
(CM)
may
be
defective
and
need
to
be
replaced.
Solenoid
Valve
will
not
open
1.
Defective
Control
Module
(CM).
1.
Verify
24
VAC
present
across
Term
1
(purple)
and
Term
3
(red)
at
Control
Module
(CM).
Remove
wires
and
check
for
continuity
between
Term
7
(black)
and
Term
8
(red).
If
the
contacts
remain
open,
Control
Module
(CM)
may
be
defective
and
need
to
be
replaced.
2.
Defective
Solenoid
Valve.
2.
Verify
control
voltage
at
Solenoid
Valve
wire
leads.
If
voltage
is
present,
Solenoid
Valve
may
be
defective
and
need
to
be
replaced.
3.
Defective
Motor
Relay
(R1).
3.
Place
a
wire
jumper
between
terminals
#6
(yellow)
and
#7
(black)
at
Motor
Relay
(R1).
If
Solenoid
Valve
opens,
Motor
Relay
(R1)
may
be
defective
and
need
to
be
replaced.
4.
Loose
wiring.
4.
Check
all
wire
terminals
and
tighten
as
necessary.
Содержание 1000-RLE
Страница 6: ...6 Engineering Guidelines Figure 1 ...
Страница 40: ...40 Appendix Appendix Cut View 1000 RLE ...
Страница 41: ...Appendix 41 Cut View 2000 RLE 3000 RLE ...
Страница 42: ...42 Appendix Assembly Drawing 1000 RLE Ice Flaker CP750 Mobile Express Ice Bin ...
Страница 43: ...Appendix 43 Assembly Drawing 2000 RLE Ice Flaker CP1500 Mobile Express Ice Bin ...
Страница 44: ...44 Appendix Assembly Drawing 3000 RLE Ice Flaker CP2500 Mobile Express Ice Bin ...
Страница 45: ...Appendix 45 Wiring Diagram Ice Flaker ...
Страница 46: ...46 Appendix Wiring Diagram 230 3 60 Air Cooled Condensing Unit supplied by Howe Corporation ...
Страница 47: ...Installation Service Manual For Use with Remote Single Condensing Unit RLE Rev Date 08 2014 ...
Страница 48: ...Parts List 1000 RLE Non Replaceable Parts Item No Description Part No ...
Страница 51: ...Parts List 2000 RLE 3000 RLE ...