19
4 211 325 / 00
HeaTIng sysTeM conTroL
4.6.2 Operating modes for holiday and absence?
Depending on how long you will be away and what your requirements are with regard to
comfort, there are different operating modes available for interrupting or reducing the heat-
ing. In any case, you will save a lot of energy and money if the rooms are not heated or
heated less during your absence.
The following table is intended as a guide for finding the best operating mode for each par
-
ticular case:
For a detailed description of how to set the operating modes, see Chap. 4.6.3, 4.6.4.
You can return to the “AUTOMATIC” function (normal heating mode) at any time by “pressing”
� � �
for 3 sec.
Application
You are going on holiday for e.g.
1 week and you know the date of
your return.
You leave home in the morning
and come back in the evening.
You will be away for an indefinite
period of time and want the liv-
ing area to be at the set reduced
temperature on your return.
You will be away for an indefi-
nite period of time during spring
or autumn and you don’t mind if
your home is cool on your return.
Operating mode
"HOLIDAY TIL"
Heating system and DHW off while
you are on holiday.
"ABSENT TIL"
Heating interrupted temporarily
"RED. HEATING"
Continuous reduced heating mode
"STANDBY"
System off - frost protection active
Function
- Heating system OFF / calorifier
frost protected (5°C)
- Room temperature set to mini-
mum (10°C)
Setting range:
from current date
to 250 days in the
future!
End of holiday = Return date. Nor-
mal heating is resumed on the day
of your return!
Early return:
Press
� � �
for 3 sec. to return to
"AUTOMATIC" (Chap. 4.6.1, 4.6.3).
Heating temporarily interrupted un-
til set time.
Setting range: 0.5 - 24 h.
Continuous reduced heating and
DHW mode (reduced, see Chap.
4.9.3) around the clock.
The entire heating system is
switched off and frost-protected!