Slide the flue outlet tube over rod so that it fits into the combustion
chamber.
See page 10 for cutting flue tube to proper length.
Flue Outlet
Tube
Combustion
Chamber
EXTERIOR INSTALLATION OF THE VENTING
VENT KIT INSTALLATION
NOTE:
Flue outlet tube, air inlet tube, and threaded rod should be measured and cut to the proper length from the back of the unit to the
outside wall of the house. There should be little to no venting showing on the outside of the house. See the table on page 10.
Combustion
Chamber
Threaded
Rod
Install the threaded rod into the combustion chamber.
See page 10 for cutting rod to proper length.
After the back of the unit is attached to the wall, bring the gas line as
shown on page 9, or follw the installation template indications. Fol-
lowing your city, local and state codes, attach the gas line to the unit.
NOTE:
The gas line runs THROUGH the wall of the house.
Gas
Line
Center the outside flue outlet spacer over the flue outlet hole on the
exterior wall and attach using four (4) drywall screws.
Flue Outlet
Spacer