Drill a pilot hole in the flue outlet circle and gas inlet circle so that a
jigsaw can be used to cut the holes out.
Pilot
Hole
Trace the template flue outlet hole and the gas inlet hole onto the wall. Mark the four (4) wall bracket mounting screw holes onto the
wall. The size of the gas inlet hole will depend upon the size of gas pipe coming into the unit. (See page 9, top graphic, items A and B).
The center of the gas inlet hole will be located 6 ¼" from the floor line.
Locate the wall bracket template included in your kit and remove
the perforated sections. Use painters’ tape to secure the wall bracket
template onto the interior wall where the heater will be located.
Wall Bracket
Template
3-1/2”
FLOOR LINE
Remove the template from the wall after the holes are marked. The
hole location markings will be present on the wall.
Marking for Wall Bracket
Mounting Holes - 4 Qty.
Marking for
Flue Outlet
Hole
Marking for
Gas Inlet
Hole
3-1/2”
FLOOR LINE