![Hotsy 9450 Скачать руководство пользователя страница 12](http://html.mh-extra.com/html/hotsy/9450/9450_operators-manual_2170318012.webp)
12
Operations
Installation
Place machine in a convenient location providing
ample support, draining and room for maintenance.
Location
The location should protect the machine from
damaging environmental conditions such as wind, rain,
and freezing temperatures.
These machines are designed for indoor
use. They must be stored indoors when
not in use.
1. The machine should be run on a level surface
where it is not readily influenced by outside
sources such as strong winds, freezing tempera-
tures, rain, etc. The unit should be located to allow
accessibility for refilling of fuel, adjustments and
maintenance. Normal precautions should be taken
by the operator of the unit to prevent excess
moisture from reaching the power unit or electrical
controls.
2. It is recommended that a partition be made
between the wash area and the machine to
prevent direct water spray from coming in contact
with the machine. Excess moisture reaching any
electric components or electrical controls will
reduce machine life and may cause electrical
shorts.
3. During installation of the machine, beware of
poorly ventilated locations or areas where exhaust
fans may cause an insufficient supply of oxygen.
Sufficient combustion can only be obtained when
there is a sufficient supply of oxygen available for
the amount of fuel being burned.
Electrical
This machine, when installed, must be electrically
grounded in accordance to local codes. Check for
proper power supply using a volt meter.
CAUTION: Use copper conductors only.
ATTENTION: Utiliser des conducteurs en cuivre
seulement.
Placement
Install this machine about 2 feet from wall to provide
adequate ventilation and servicing space. This
equipment incorporates parts such as snap switches or
similar parts that tend to produce arcs or sparks. There-
fore, when located in a garage, it should be in a room or
enclosure provided for the purpose or should be
installed 18” (457)mm) or more above the floor.
Water Source
The water source for the machine should be supplied
by a 5/8" I.D. garden hose with a city water pressure of
not less than 30 psi. If the water supply is inadequate,
or if the garden hose is kinked, the attached pressure
washer will run very rough and the burner will not fire.
Connection
Connect the wand, nozzle, hose and spray gun (where
applicable). On pipe thread connections, use teflon
tape to avoid water leaks.
(See Component Identification.)
Venting
Adding exhaust vent pipe to your oil fired burner is not
recommended. It restricts air flow, causing carbon
build-up, which affects the operation, and increases
maintenance on the coil. If a stack must be used,
refrain from using 90° bends. If the pipe can not go
straight up then use only 45° bends and go to the next
size pipe. The overall pipe length must not exceed 6
feet in length.
9450 / 9460 Operators Manual - Oil Fired 8.914-364.0 - G
Содержание 9450
Страница 2: ...2 9450 9460 Operators Manual Oil Fired 8 914 364 0 G Machine Data Label ...
Страница 9: ...9 Notes 9450 9460 Operators Manual Oil Fired 8 914 364 0 G ...
Страница 22: ...22 Notes 9450 9460 Operators Manual Oil Fired 8 914 364 0 G ...
Страница 23: ...23 Parts Parts 1 103 905 0 1 103 907 0 9450 9460 9450 9460 Operators Manual Oil Fired 8 914 364 0 G ...
Страница 28: ...28 Control Panel 9450 9460 Operators Manual Oil Fired 8 914 364 0 G 5 4 9 2 14 12 7 6 8 9 1 3 10 11 15 13 ...
Страница 34: ...34 PHW Series Wayne Burner 9450 9460 Operators Manual Oil Fired 8 914 364 0 G ...
Страница 36: ...8 914 364 0 Printed in U S A ...