background image

HOTSTREAM

HOTSTREAM

CONTINUOUS HOT WATER SYSTEM

SHOWER • HANDWASH • HAIRDRESSER

•  Provides a continuous supply    

 

  of hot water

•  Turns cold water into

 HOT – Instantly!

HOT – Instantly!

•  Can be used for shower,
  handwashing or hairdresser

•  Compact and wall-mounted, 
  saving floor space

•  No storage of water or long 
  hot pipe runs

Hairdresser

HS / HDT

Basin

HS / BT

Oversink

HS / OST

Shower

HS / ST

Содержание HS10/2

Страница 1: ...des a continuous supply of hot water Turns cold water into HOT Instantly HOT Instantly Can be used for shower handwashing or hairdresser Compact and wall mounted saving floor space No storage of water or long hot pipe runs Hairdresser HS HDT Basin HS BT Oversink HS OST Shower HS ST ...

Страница 2: ...CP2 Appliance must be earthed and have an isolating switch Water Pressure Check water pressure before installtion Minimum 35psi 250 KPA Maximum 75psi 500 KPA Inlet connection 1 2 BSP 15mm Outlet Tapware Open vented taps Only HOTSTREAM tapware should be used Electrical Power Please note These products HS 4 1 230V 18 amps must have an independent 4kW single phase power supply from the HS 6 1 230V 25...

Страница 3: ... installation The water pressure must not exceed 500kPa 72psi If so a pressure limiting valve will need to be fitted High water pressure will damage the unit UNIT REPLACEMENT ISOLATE POWER CHECK EXISTING TAP OUTLETS SHOWER HEADS HOSES SINK ARMS AND ROSES FOR BLOCKAGES AND WATER PRESSURE WHEN REPLACING A HEATER UNIT Before turning on the power to the HOTSTREAM unit please run the water through the ...

Страница 4: ...ING INSTRUCTIONS PLEASE ENSURE THIS INFORMATION IS GIVEN TO YOUR CUSTOMER Manufactured and Distributed by HOTSTREAM LTD 199 Bush Rd RD2 Mosgiel Dunedin 9092 Phone 03 470 1498 Email sales hotstream nz Web www hotstream nz This unit is a fully automatic resistance heated water heater After this heater has been correctly installed the heater may be used as follows Cold Water ambient temperature only ...

Страница 5: ...8 units a 11 2 feed pipe would generally be required rather than a 1 2 pipe depending upon pressure 8 We recommend fitting a 350 kPa pressure limiting valve to all installations where the incoming pressure exceeds 500 kPa WARNING Water heater must not be switched on if there is a possibility that the water in the heater is frozen 3 FOR HEATERS INSTALLED ABOVE THE BASIN OR IN SHOWERS 1 For new inst...

Страница 6: ...e Remove filter rinse it under cold water to clean it then replace it and the O ring Reconnect heater to tap body ensuring washers are in place In areas of particularly hard or dirty water consideration should be given to the installation of an additional water filter TROUBLE SHOOTING PROBLEM SOLUTION OR REASON Microswitch malfunction element ruptured Replacement instructions are included in new k...

Страница 7: ...itch 2 Aerated water supply 3 Lack of water 4 Incorrectly adjusted 5 Back pressure on element 1 Replace 2 Bleed air from supply 2a Fit air eliminator valve 3 Check pressure 4 Contact nearest service agent 5 Blocked outlet gauzes or roses When cold water is mixed the light goes out 1 Blocked tap outlets 1 Clean or replace Water not hot enough 1 Tap usage 2 Usage and kW rating 1 The more open the ho...

Страница 8: ...r perished 2 Grit under washer or on seat 1 Replace 2 Remove and clean Neon does not glow 1 Neon blown 2 No power 1 Replace 2 Check power supply Heater unit leaks 1 Loose bolts 2 Loose element screws 3 Base plate cracked 4 Blocked outlet gauzes or Rose 5 Water pressure too high 6 Unit screwed back too tightly or unevenly 1 Tighten to 28in lbs torque 2 Tighten element screws 3 Replace unit 3a Check...

Страница 9: ...4 m m 195 mm 252 mm Depth 56 mm Hotstream Back Plate Dimensions Note Not to scale ...

Страница 10: ...Correct position of the Micro switch rod bar Micro Switch Assembly ...

Страница 11: ...Hotstream Basin Tap Unit Installation ...

Страница 12: ......

Отзывы: