BEFORE YOU INSTALL

HOTflow

®

 engine heaters feature an integrated pump that circulates warm coolant throughout the entire engine at uniform 

temperatures. Constant circulation of the coolant eliminates hot spots that can deteriorate heater hoses, harm engine seals 
and diminish coolant life. However, initial installation of the heating system is critical; even seemingly minor adjustments to port 
location, hose routing or heater positioning may help ensure your HOTflow

®

 CSM heater preheats your engine effectively.

DANGER

!

Personal injury: 

This product generates heat during operation. Operation of 

a heating system with closed isolation valves could result in high pressure and 
serious injury. It is the responsibility of the installer and operator to ensure that no 
unsafe condition can result from the generation of pressure. In EU countries, PED 
(97/23/EC) compliant pressure relief may be required (125 psi maximum).

Hazardous voltage:

 Before wiring, servicing or cleaning the heating system, 

turn off the power and follow your organization’s lockout and tagout procedure. 
Failure to do so could allow others to turn on the power unexpectedly, resulting in 
harmful or fatal electrical shock.

CAUTION

!

Electrical hazard:

 Power source must be properly grounded and in accordance 

with national and local electrical codes. A user-supplied circuit breaker (rated at 
the appropriate amperage) is required for use in the main power feed line. Do not 
connect heater prior to installation.

NOTICE

Read instructions carefully

: The Hotstart warranty does not cover any damage 

that a heating system may sustain from improper installation, improper operation, 
improper specification or corrosion. Before installing your heater, be sure you have 
the right heating system for your application. Carefully read all instructions before 
installing and energizing your heater. The safety of any system incorporating 
this heater is the responsibility of the assembler. The safe and proper use of this 
heater is dependent upon the installer following sound engineering practices. 
If the equipment is used in a manner not specified by the manufacturer, the 
protection provided by the equipment may be impaired. All applicable electrical 
safety standards defined by local jurisdictions must be followed. (Reference EU 
directive 2006/95/EC in EU countries.)

INSTALLATION INSTRUCTIONS

HOTflow

®

 HEATER 

CSM MODEL 

EURO

page

 1

installation

 

instructions

Hot

flow

®

 

csm

 

Heater

c u s t o m e r

 

s e r v i c e

:

 

5 0 9 . 5 3 6 . 8 6 6 0

[email protected]

 

|

 

www.hotstart.com

Read carefully for proper 
installation and operation.

Hotstart Manufacturing, Inc. is the owner of 

all trademarks and copyrightable material 

contained herein; all rights are reserved; 

no form of reproduction is authorized 

without prior written consent from Hotstart 

Manufacturing, Inc.

Original Instructions

216229-010 rev3 

A. 

Discharge port

B. 

Pump/motor

C. 

Mounting base

D. 

Element assembly

E. 

Thermostat  

(in element assembly)

F. 

Customer control 

wiring entrance

G. 

Power in wiring 

entrance

H. 

Suction port

IOM216229-010 rev3

C

C

A

B

D

E

F

G

H

Corporate & Manufacturing 
Headquarters

5723 E. Alki Ave.
Spokane, WA 99212 USA

509.536.8660

[email protected]

Oil & Gas Office

21732 Provincial Blvd.  
Suite 170
Katy, TX 77450 USA

281.600.3700

[email protected]

Railroad Office

8915 Broadway  
Merrillville, IN 46410 USA

219.648.2448

railroad@hotstart.com

Europe Office

Hotstart Europe GmbH
Hansestraße 79
51149 Köln, Germany

+49.2203.98137.30

[email protected]

Asia Pacific Office

Hotstart Asia Pacific Ltd.
2-27-15-4F Honkomagome
Bunkyo-ku, Tokyo
113-0021, Japan

+81.3.6902.0551

[email protected]

C

C

A

B

D

E

F

G

H

Figure 1.  Typical CSM Euro model (above)  

and side view (below). Style and configuration 

may vary.

Содержание HOTflow

Страница 1: ...for your application Carefully read all instructions before installing and energizing your heater The safety of any system incorporating this heater is the responsibility of the assembler The safe and proper use of this heater is dependent upon the installer following sound engineering practices If the equipment is used in a manner not specified by the manufacturer the protection provided by the e...

Страница 2: ...ctly to engine Engine vibration will damage heater If the heater is installed with rigid pipe connect flexible hose to inlet and outlet to isolate from vibration Heater orientation CSM units must be installed with discharge port pointing directly upward See Fig 2 on following page Do not mount at an angle An incorrectly oriented heater may cause heater failure 7 Select a heater mounting position T...

Страница 3: ... typically to ignition system NOTICE The heating system must be activated only while the engine is not in operation To enable automatic shutdown the heating system requires a connected 24 V DC signal page 3 installation instructions HOTflow csm heater Figure 2 Example CSM installation Style B shown The return hose continuously rises to the engine and supply hose continuously descends to the heater...

Страница 4: ... tank See Fig 5 page 4 installation instructions HOTflow csm heater 1 Disconnect heater from power source Allow heating system to cool 2 Remove element assembly enclosure cover h If cleaning tank unscrew wiring enclosure screws to remove wiring enclosure Unscrew element plate screws Remove plate and element from tank h If replacing thermostat disconnect terminals from thermostat sensing unit spade...

Отзывы: