7
WWW.HOTRONIX.COM
Entering Application Settings
Before you begin heat applying, verify the appropriate application settings are entered for
both lower platens. Application settings for lower platen A and platen B are stored separately.
To enter application settings for lower platen A, the upper platen must be in the A position.
If it is in the B position, depress the foot pedal (4.2) while the Auto Shuttle function is enabled
(3.2) to shuttle to A position.
Select a preset material application (7.1) for the A position or manually enter temperature,
pressure and time based on transfer material instructions.
Shuttle the upper platen to the B position using the foot pedal (4.2).
Select a preset material application (7.1) for the B position or manually enter temperature,
pressure and time based on transfer material instructions. For best results, temperature
settings for A and B positions should match.
Basic Printing
Position the garment and design.
Shuttle the upper platen over the garment and design using the foot pedal.
Press both Print Buttons located on the side of the press.
The upper platen will lower into PRESS position. The timer will automatically begin to count down.
When the Print Cycle is complete, the top platen will return to the UP position.
CAUTION:
When Auto Shuttle mode is enabled (Arrow icon), the upper platen will automatically shuttle to the opposite platen.
If a second application is desired, repeat previous steps.
Shuttle and Tack Modes
Touch the Shuttle icon (3.2) to cycle through three shuttle modes:
• Auto: shuttle automatically after each Print Cycle or when the foot pedal is pressed
• Foot pedal: shuttle only when the foot pedal is pressed
• Off: air-operated shuttling is disabled and the controller housing must be shuttled by hand.
The Print Cycle will not begin unless the upper platen is in either the A or B position.
NOTE:
Auto Shuttle can be disabled for individual preset stages (7.6) for a heated post-cure effect.
Touch the Tack Mode icon (3.2) to toggle ON/OFF. Tack mode is useful for experimenting, fine-tuning print recipes or very brief application times.
• Tack Mode On: press and hold both Print Buttons to start Print Cycle. Print Cycle completes when buttons are released
• Tack Mode OFF: press and hold both Print Buttons to start Print Cycle. Print Cycle completes when countdown timer reaches 0.
Pressing the print buttons a second time during the print cycle will interrupt it.
Prepare to Print