background image

5 of 15

Indesit

 

Company

Service Manual UK

English

MODEL INTRODUCTION

The models included in this publication are 1500 and 1700 mm high static freezers that were 
introduced in March 2007. Models are A Band appliances with similar appearance furniture.

For colour information, refer to the Specifications page.

The appliance is 'static' design so defrosting is actioned manually. When the user defrosts the 
freezer, the defrost water drains into the liner base and is channelled to a drain hole exiting through 
a spout moulded into the plinth/kickstrip.

All models have wheels at the rear and adjustable feet at the front.

Doors are reversible, but do require a T20 Torx key to remove the plinth/kickstrip.

A thermostat mounted behind the control panel/top facia controls the temperature; the super freeze 
switch and indicator lamps are also mounted in the same area.

Содержание RZ150G

Страница 1: ...Company UK Ltd 2007 Reg Office Peterborough PE2 9JB Registered in London 106725 Service Information HOTPOINT FREESTANDING FREEZERS Model Comm Covered Code RZ150P 44354 RZ150G 44355 5407383 Issue 1 Ma...

Страница 2: ...dless power tools are forbidden within the storage area working area and vehicles used to transport Isobutane 9 The carrying case for the scales and refrigerant must display a red flammability label P...

Страница 3: ...t aluminium canister placed in an upright position on the weighing scales provided 4 All used canisters must be a returned as scrap and therefore left out for the driver to collect and return for disp...

Страница 4: ...Bruto Brut Compr Kompr Syst R 134 a kg 0 090 Gross Bruto Brut 340 Net Util Utile Gross Bruto Brut Freez Capac Poder de Cong 75 Made in 13918 Test P S I Pressure HIGH 235 LOW 140 kg 24 h 4 0 Class Cla...

Страница 5: ...ic design so defrosting is actioned manually When the user defrosts the freezer the defrost water drains into the liner base and is channelled to a drain hole exiting through a spout moulded into the...

Страница 6: ...band models 40dB Climate Class Rating Plate A band SN N ST 10 C to 38 C Refrigeration Type Static Wire On Tube WOT DIMENSIONS WEIGHT Models RZ150 Height 1500 mm Width 600 mm Depth 655 mm Weight Gross...

Страница 7: ...uency 50 Hz Absorption Current Normal Operation 0 7 Amps COMPRESSOR WINDING Manufacturer JIAXIPERA Type I D ZBT1114CY Winding Resistance Start 16 0 Run 13 3 Refrigerant Grams R600a Refer to the applia...

Страница 8: ...OF APPLIANCE TEMPERATURE CONTROL PANEL APPLIANCE INTERIOR SUPER FREEZE Button SUPER FREEZE Indicator Lamp ALARM Indicator Lamp TEMPERATURE Control Knob POWER Indicator Lamp FREEZER and STORAGE Compart...

Страница 9: ...9 of 15 Indesit Company Service Manual UK English NOTES...

Страница 10: ...anual Read the instructions on the next page fully and refer to the diagrams below before carrying out the door reversal Also before commencing the door reversal you will require the left door closure...

Страница 11: ...xing plate Transfer them to the other side Remove the hinge pin from the right hand side of the hinge and retain until the plinth is in place Insert the plinth blanking plate supplied with the applian...

Страница 12: ...ed 4 Brown Thermostat 3 5 Black Thermostat 4 6 Green Yellow Earth 1 Not Used 2 Blue Neutral 3 Not Used 4 Brown Live 5 Black Compressor Overload 6 Green Yellow Earth Yellow Super Freeze Switch 3 THERMO...

Страница 13: ...erminal 1 and Control Harness Plug 4 4 CONTROL PANEL INDICATOR LAMPS Alarm Indicator Lamp Red Thermostat 6 Blue Neutral Link to Power Indicator Lamp Blue Control Harness Plug 2 Power Indicator Lamp Br...

Страница 14: ...it Company English THEORETICAL WIRING DIAGRAM ELECTROLUX ACC ZEM JIAXIPERA COMPRESSORS OVERLOAD COMPRESSOR SUPER FREEZE INDICATOR LAMP POWER INDICATOR LAMP CAPACITOR if fitted SUPER FREEZE SWITCH ALAR...

Страница 15: ...anual UK English PARTS and ACCESSORIES To order parts and accessories contact our National Mail Order Parts Hotline 08709 077 077 Monday to Friday 8 00am to 5 30pm Saturday 8 30am to 12 00 noon or onl...