Gas burners

Each burner can be adjusted to one of the following
settings using the corresponding control knob:

Off

\

Maximum

Minimum

To light one of the burners, hold a lit match or lighter
near the burner and, at the same time, press down
and turn the corresponding knob anti-clockwise to the
maximum setting.
Since the burner is fitted with a safety device, the
knob should be pressed for approximately 2-3
seconds to allow the automatic device keeping the
flame alight to heat up.
To light a burner, simply press the corresponding
knob all the way in and then turn it in the counter-
clockwise direction to the "High" setting, keeping it
pressed in until the burner lights.

!

 If a flame is accidentally extinguished, turn off the

control knob and wait for at least 1 minute before
trying to relight it.

To switch off the burner, turn the knob in a clockwise
direction until it stops (when reaches the “•” position).

Practical advice on using the burners

To ensure the burners operate efficiently:

• Use appropriate cookware for each burner (see

table) so that the flames do not extend beyond the
bottom of the cookware.

• Always use cookware with a flat base and a cover.

• When the contents of the pan reach boiling point,

turn the knob to minimum.

Burner

 
Fast (R)

Reduced Fast (RR)

Semi Fast (S)

Auxiliary (A)

Triple Crown (TC)

Ø Cookware Diameter (cm)

24 - 26

22 - 24

16 - 20

10 - 14

24 - 26

To identify the type of burner, refer to the designs in
the section entitled, "Burner and Nozzle
Specifications".

Start-up and use

Содержание GE640KX

Страница 1: ...up and use 8 Practical advice on using the burners Precautions and tips 9 General safety Disposal Recycling Disposal Information Maintenance and care 10 Switching the appliance off Cleaning the applia...

Страница 2: ...on indirectly i e from adjacent rooms fitted with air circulation tubes as described above However these rooms must not be communal rooms bedrooms or rooms that may present a fire hazard Liquid petrol...

Страница 3: ...o the gas system must be carried out in such a way as not to place any strain of any kind on the appliance There is an adjustable L shaped pipe fitting on the appliance supply ramp and this is fitted...

Страница 4: ...y device thermocouple fitted If the device fails to work when the burners are set to the low flame setting increase this low flame setting using the adjusting screw 5 Once the adjustment has been made...

Страница 5: ...hermal power kW p c s Reduced Thermal power kW p c s Nominal Thermal power kW p c s Nominal By pass 1 100 mm Nozzle 1 100 mm Nozzle 1 100 mm Flow g h Flow g h At 15 C and 1013 mbar dry gas Propane P C...

Страница 6: ...switch in compliance with BS 5733 which is accessible without moving the appliance Please note for appliances with a rating greater than 13 amp eg electric hob double ovens and freestanding electric c...

Страница 7: ...dels GAS BURNERS differ in size and power Use the diameter of the cookware to choose the most appropriate burner to cook with Control Knobs for GAS BURNERS adjust the power or the size of the flame GA...

Страница 8: ...d then turn it in the counter clockwise direction to the High setting keeping it pressed in until the burner lights If a flame is accidentally extinguished turn off the control knob and wait for at le...

Страница 9: ...liance yourself Repairs carried out by inexperienced persons may cause injury or further malfunctioning of the appliance Contact a Service Centre see Assistance Always make sure that pan handles are t...

Страница 10: ...bsorbent kitchen roll The removable parts of the burners should be washed frequently with warm water and soap and any burnt on substances removed For hobs which ligth automatically the terminal part o...

Страница 11: ...ounted correctly There are draughts near the appliance You pressed the knob all the way in You keep the knob pressed in long enough to activate the safety device The gas holes are not blocked in the a...

Страница 12: ...a result of improper installation Replacement of any consumable item or accessory These included but not limited to plugs cables batteries light bulbs fluorescent tubes and starters covers and filter...

Страница 13: ...UK 08448 225 225 Republic of Ireland 0818 313 413 www hotpointservice co uk Appliance Registration We want to give you additional benefits of Hotpoint ownership To activate your free 5 year parts guar...

Страница 14: ...GB 14 PLEASE PHONE US TO REGISTER YOUR APPLIANCE AND ACTIVATE YOUR PARTS GUARANTEE ON 08448 24 24 24 Notes...

Страница 15: ...GB 15 PLEASE PHONE US TO REGISTER YOUR APPLIANCE AND ACTIVATE YOUR PARTS GUARANTEE ON 08448 24 24 24 Notes...

Страница 16: ...GB 16 PLEASE PHONE US TO REGISTER YOUR APPLIANCE AND ACTIVATE YOUR PARTS GUARANTEE ON 08448 24 24 24 Notes 01 2011 195053075 04 XEROX FABRIANO...

Отзывы: