PLEASE PHONE US TO REGISTER YOUR APPLIANCE AND ACTIVATE YOUR PARTS GUARANTEE ON 08448 24 24 24

!

 The installation instructions for cooking ranges shall

include a recommendation that such appliances
should not be placed adjacent to a door access to
minimise the likelihood of persons using the door
making contact with pans on the hob surface.

!

 Before operating your new appliance please read this

instruction booklet carefully. It contains important information
for safe use, installation and care of the appliance.

!

 Please keep these operating instructions for future

reference. Pass them on to possible new owners of the
appliance.

Positioning

!

 Keep packaging material out of the reach of children. It

can become a choking or suffocation hazard (

see

Precautions and tips

).

!

 The appliance must be installed by a qualified professional

according to the instructions provided. Incorrect installation
may cause harm to people and animals or may damage
property.

!

 This unit may be installed and used only in permanently

ventilated rooms in accordance with British Standard Codes
Of Practice: B.S. 6172 / B.S. 5440, Par. 2 and B.S. 6891
Current Editions. The following requirements must be
observed:

• The room must be equipped with an air extraction system

that expels any combustion fumes. This may consist of a
hood or an electric fan that automatically starts each time
the appliance is switched on.

The room must also allow

proper air circulation, as air is
needed for combustion to occur
normally. The flow of air must not
be less than 2 m

3

/h per kW of

installed power.
The air circulation system may
take air directly from the outside
by means of a pipe with an inner
cross section of  at least 100 cm

2

;

the opening must not be
vulnerable to any type of
blockages.

The system can also provide the
air needed for combustion
indirectly, i.e. from adjacent rooms

fitted with air circulation tubes as described above.
However, these rooms must not be communal rooms,
bedrooms or rooms that may present a fire hazard.

• Liquid petroleum gas sinks to the floor as it is heavier

than air. Therefore, rooms containing LPG cylinders must
also be equipped with vents to allow gas to escape in the
event of a leak. As a result LPG cylinders, whether
partially or completely full, must not be installed or stored
in rooms or storage areas that are below ground level
(cellars, etc.). It is advisable to keep only the cylinder
being used in the room, positioned so that it is not
subject to heat produced by external sources (ovens,
fireplaces, stoves, etc. ) which could raise the
temperature of the cylinder above 50°C.

Fitting the appliance

Gas and mixed hobs are manufactured with type X degree
protection against overheating. The following precautions
must be taken when installing the hob:

• Kitchen cabinets adjacent to the appliance and taller

than the top of the hob must be at least 600 mm from the
edge of the hob.

• Hoods must be installed according to their relative

installation instruction manuals and at a minimum
distance of 650 mm from the hob.

• Place the wall cabinets adjacent to the hood at a

minimum height of 420 mm from the hob (

see figure

).

If the hob is installed beneath a
wall cabinet, the latter must be
situated at a minimum of 700 mm
above the hob (

see figure

).

• The installation cavity should have the dimensions

indicated in the figure.

Fastening hooks are provided, allowing you to fasten the

hob to tops that are between 20 and 40 mm thick. To
ensure the hob is securely fastened to the top, we
recommend you use all the hooks provided.

555 mm

55 mm

475 mm

Installation

Enlarging the ventilation slot
between window and floor.

Adjacent
Room

Room to be
Vented

A

Examples of ventilation holes
for comburant air.

In a chimney stack or branched flue. 
(exclusively for cooking appliances)

Directly to 
the Outside

600mm min.

600mm min.

700mm min.

Содержание GE640KX

Страница 1: ...up and use 8 Practical advice on using the burners Precautions and tips 9 General safety Disposal Recycling Disposal Information Maintenance and care 10 Switching the appliance off Cleaning the applia...

Страница 2: ...on indirectly i e from adjacent rooms fitted with air circulation tubes as described above However these rooms must not be communal rooms bedrooms or rooms that may present a fire hazard Liquid petrol...

Страница 3: ...o the gas system must be carried out in such a way as not to place any strain of any kind on the appliance There is an adjustable L shaped pipe fitting on the appliance supply ramp and this is fitted...

Страница 4: ...y device thermocouple fitted If the device fails to work when the burners are set to the low flame setting increase this low flame setting using the adjusting screw 5 Once the adjustment has been made...

Страница 5: ...hermal power kW p c s Reduced Thermal power kW p c s Nominal Thermal power kW p c s Nominal By pass 1 100 mm Nozzle 1 100 mm Nozzle 1 100 mm Flow g h Flow g h At 15 C and 1013 mbar dry gas Propane P C...

Страница 6: ...switch in compliance with BS 5733 which is accessible without moving the appliance Please note for appliances with a rating greater than 13 amp eg electric hob double ovens and freestanding electric c...

Страница 7: ...dels GAS BURNERS differ in size and power Use the diameter of the cookware to choose the most appropriate burner to cook with Control Knobs for GAS BURNERS adjust the power or the size of the flame GA...

Страница 8: ...d then turn it in the counter clockwise direction to the High setting keeping it pressed in until the burner lights If a flame is accidentally extinguished turn off the control knob and wait for at le...

Страница 9: ...liance yourself Repairs carried out by inexperienced persons may cause injury or further malfunctioning of the appliance Contact a Service Centre see Assistance Always make sure that pan handles are t...

Страница 10: ...bsorbent kitchen roll The removable parts of the burners should be washed frequently with warm water and soap and any burnt on substances removed For hobs which ligth automatically the terminal part o...

Страница 11: ...ounted correctly There are draughts near the appliance You pressed the knob all the way in You keep the knob pressed in long enough to activate the safety device The gas holes are not blocked in the a...

Страница 12: ...a result of improper installation Replacement of any consumable item or accessory These included but not limited to plugs cables batteries light bulbs fluorescent tubes and starters covers and filter...

Страница 13: ...UK 08448 225 225 Republic of Ireland 0818 313 413 www hotpointservice co uk Appliance Registration We want to give you additional benefits of Hotpoint ownership To activate your free 5 year parts guar...

Страница 14: ...GB 14 PLEASE PHONE US TO REGISTER YOUR APPLIANCE AND ACTIVATE YOUR PARTS GUARANTEE ON 08448 24 24 24 Notes...

Страница 15: ...GB 15 PLEASE PHONE US TO REGISTER YOUR APPLIANCE AND ACTIVATE YOUR PARTS GUARANTEE ON 08448 24 24 24 Notes...

Страница 16: ...GB 16 PLEASE PHONE US TO REGISTER YOUR APPLIANCE AND ACTIVATE YOUR PARTS GUARANTEE ON 08448 24 24 24 Notes 01 2011 195053075 04 XEROX FABRIANO...

Отзывы: