![Hotpoint GE640KX Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/hotpoint/ge640kx/ge640kx_operating-instructions-manual_2167071005.webp)
GB
5
PLEASE PHONE US TO REGISTER YOUR APPLIANCE AND ACTIVATE YOUR PARTS GUARANTEE ON 08448 24 24 24
Burner and nozzle specifications
Table 1 Liquid Gas Natural Gas
Supply pressures
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
28-30
20
35
37
25
45
20
17
25
Fast (Large) (R)
Reduced Fast (RR)
Semi Fast (Medium) (S)
Auxiliary (Small) (A)
Triple Crown (TC)
100
100
75
55
130
0.70
0.70
0.40
0.40
1.50
3.00
2.60
1.65
1.00
3.30
39
39
28
28
61
86
80
64
50
91
218
189
120
73
240
214
186
118
71
236
3.00
2.60
1.65
1.00
3.60
116
110 (Y)
96
79
145 (H1)
286
248
157
95
343
Burner
Diameter
(mm)
Thermal
power
kW
(p.c.s.*)
(Reduced)
Thermal
power
kW
(p.c.s.*)
(Nominal)
Thermal
power
kW
(p.c.s.*)
(Nominal)
By-pass
1/100
(mm)
Nozzle
1/100
(mm)
Nozzle
1/100
(mm)
***
**
Flow*
(g/h)
Flow*
(g/h)
*
At 15°C and 1013 mbar-dry gas
**
Propane
P.C.S. = 50.37 MJ/kg.
***
Butane
P.C.S. = 49.47 MJ/kg.
Natural
P.C.S. = 37.78 MJ/m
3
R
A
S
S
RR
A
S
TC
TC
GE 640
GE 641 T
GE 640KX
GE 640 TX
GE 641TKX
Electrical
connections
DATA PLATE
see data plate
This appliance conforms to the following
European Economic Community directives:
- 2006/95/EEC dated 12/12/06 (Low
Voltage) and subsequent amendments
- 2004/108/EEC dated 15/12/04
(Electromagnetic Compatibility) and
subsequent amendments
- 93/68/EEC dated 22/07/93 and
subsequent amendments.
- 2009/142/EEC dated 30/11/09 (Gas) and
subsequent amendments.
- 2002/96/EC and subsequent
amendments.