Installation
The installation procedure is illustrated in the
fi
rst pages
of this manual.
The installation must be done by a quali
fi
ed technician.
Electrical hook up
The mains voltage must match that given on the ratings
label inside the hood itself. If the hood has a power plug,
connect the hood to an easily accessible regulatory power
socket. If it does not (direct connection to the mains), or the
socket is not easily accessible, install a two-pole regulatory
switch to enable total disconnection from the mains in case
of category III overvoltage, as required by the installation
regulations.
Caution!
Always check that the mains cable is hooked
up properly and check that it operates correctly before
reconnecting the hood to the mains.
Air exhaust
(for ducted units)
Connect the hood to a duct and wall exhaust hole of a
diameter equal to that of the air outlet
fl
ange. Using a smaller
diameter tube and exhaust hole reduces the extraction
capacity of the hood and also increases its running noise.
The manufacturer is not liable for any consequences of
doing so.
!
Use the shortest duct required to achieve the purpose.
!
Use a duct with as few bends as possible
!
Avoid suddenly changing the diameter of the duct.
!
The duct must have as smooth an inner surface as
possible.
!
The duct must be made of regulatory material.
!
Do not connect the hood to
fl
ues carrying combustion
fumes from other equipment (boilers, TBOXs, stoves, etc.).
!
Observe the instructions of the competent authorities in
relation to the air exhaust. The air being exhausted may not
be exhausted into a wall cavity unless the cavity in question
is speci
fi
cally intended for this purpose.
!
Equip the room with air intakes to prevent the hood creating
suction pressure in the interior (this must not exceed 0.04
mbar).
!
The manufacturer is not liable for any consequences of
failure to observe these instructions.
Filter or ducted?
!
Your hood is supplied as a ducted unit.
If you wish to use it as a
fi
lter unit, you must install the proper
ACCESSORY KIT.
Note:
If supplied with the hood, the accessory active
charcoal
fi
lter unit may already be installed.
Instructions for transforming the hood from the ducted to the
fi
lter version are given in this manual (see “Filter version”).
Ducted version
The hood puri
fi
es the air and expels it outdoors via an
exhaust duct (dia. 150mm) connected to its outlet
fl
ange.
The diameter of the exhaust tube must be equal to that of
the outlet
fl
ange.
Caution!
The exhaust duct is not supplied and must be
purchased separately.
When routed horizontally, the tube must be angled slightly
upwards (around 10°) to enable the air to be conveyed
outdoors more easily. If the hood is
fi
tted with charcoal
fi
lters, they must
fi
rst be removed.
Filter version
The hood puri
fi
es the air and returns it to the room. This
version of the hood requires installation of an accessory
active charcoal
fi
lter unit.
This version requires an air de
fl
ector, a reduction adapter
and the charcoal
fi
lter/s. The top tube must have its air
outlet slots uppermost.
Technical data
Model
Height
(cm)
Width
(cm)
Depth
(cm)
dia. of
exhaust tube
(cm)
TBOX 60cm
61-82
59.8
50
15/12
TBOX 90cm
61-82
89.9
50
15/12
Model code
Bulb (V)
Bulb draw (W) Total draw (W)
HNB 9.6 LMI X/HA
Led
2 x 3
176
HNB 9.5S AM X/HA
HNB 6.5S AM X/HA
Halogen
2 x 20
185
Model code
Bulb (V)
Bulb draw (W) Total draw (W)
HNB 6.5S CB X/HA
HNB 9.5S CB X /HA
LC
2 x 25
195
Model code
Bulb (V)
Bulb draw (W) Total draw (W)
HNB 6.7 AD X/HA
HNB 9.8 ADI X /HA
Halogen
2 x 20
240
290
Power
Voltage
Cap
Dimensions
Halogen 25 W
2 x 25 W
230 V
G9
L40xØ14
Halogen 20 W
2 x 20 W
12 V
G4
L30xØ10
LED
*
Risk Group 1 according to Standard EN 62471
The hoods are conforming to the following EC
Directives:
• “Low voltage” Directive 2006/95/EC (12-12-2006)
• “EMC” Directive 2004/108/EC (15-12-2004)
*
Only available in certain models
Содержание HNB 6.5S AM X/HA
Страница 4: ...4 6x 8 x 40 6x 5 x 45 1x 2x 1x 150 125mm 150mm 1x 1x 4x 3 5 x 9 5 2 3 4 5...
Страница 5: ...5 32 cm min 1A 150mm 1B 150mm 120mm 120 150 120mm 120 150 150mm...
Страница 6: ...6 4 6 3 7 5 2 650 m m 550 m m x6 8 mm x6 x6 x2 5 m m...
Страница 7: ...7 11 10 x2 12 13 8 9 1 2 3 x2 150 120...
Страница 8: ...8 A 16 18 14 150 3 5 x 9 5 x2 15 17...
Страница 21: ...21...
Страница 22: ...22 65 55 i i i i i i i i i i i i i i i i i i i i i i i i i I i i i i i i i i i i i i i i i i i i...
Страница 27: ...27...
Страница 69: ...UA 69 T5 5 T6 A B T4 T4 6 T4 T1 i i i i i i i i i i i i i i i i i i i i A A B...
Страница 81: ...81 KZ T5 5 T6 A B T4 T4 6 T4 T1 A B...
Страница 82: ...82 KZ B 1 2 3 LED WEEE EC 2012 19 5...
Страница 83: ...83 KZ...
Страница 84: ...84 KZ 195098208 06 0 9 2 0 1 3 X E R O X FA B R I A N O...