8
GB
We recommend cleaning the oven before using it for
the first time, following the instructions provided in the
„Care and maintenance” section.
S S
R
A
Table of burner and nozzle specifications
TECHNICAL DATA
Oven dimensions
(HxWxD)
34x38x44 cm
Volume
57 l
Useful
measurements
relating to the oven
compartment
width 42 cm
depth 44 cm
height 17 cm
Power supply voltage
and frequency
see data plate
Burners
may be adapted for use with any
type of gas shown on the data
plate, which is located inside the
flap or, after the oven
compartment has been opened,
on the left-hand wall inside the
oven.
EC Directives: 2006/95/EC dated
12/12/06 (Low Voltage) and
subsequent amendments -
2004/108/EC dated 15/12/04
(Electromagnetic Compatibility)
and subsequent amendments -
2009/142/EC dated 30/11/09
(Gas) and subsequent
amendments - 93/68/EEC dated
22/07/93 and subsequent
amendments - 2002/96/EC.
1275/2008 (Stand-by/ Off mode)
Table 1
Liquid Gas
Natural Gas
Burner Diameter
(mm)
Thermal Power
kW (p.c.s.*)
By Pass
1/100
Nozzle
1/100
Flow*
g/h
Nozzle
1/100
Flow*
l/h
Nozzle
1/100
Flow*
l/h
Nominal
Reduced
(mm) (mm) *** ** (mm) (mm)
Fast
(Large)(R)
100 3.00 0.7 41 87 218
214
128 286 145
286
Semi Fast
(Medium)(S)
75 1.90 0.4
30 69 138
136 104 181 115 181
Auxiliary
(Small)(A)
51 1.00 0.4 30 50 73
71 78 95 85 95
Oven
- 2.80 1.0
46 80 204
200 119 267 132 257
Grill
- 2.30 -
-
75 167
164 114 219 139 227
Supply
Pressures
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
28-30
20
35
37
25
45
20
17
25
13
6,5
18
*
At 15°C 1013 mbar-dry gas
***
Butane P.C.S. = 49,47 MJ/Kg
**
Propane P.C.S. = 50,37 MJ/Kg
Natural P.C.S. = 37,78 MJ/m³
!
Should the gas pressure used be different (or vary
slightly) from the recommended pressure, a suitable
pressure regulator must be fitted to the inlet hose in
accordance with current national regulations relating to
“regulators for channelled gas”.
Safety Chain
! In order
to prevent
accidental
tipping of the
appliance, for
example by
a child clim-
bing onto the
oven door, the
supplied safety
chain MUST be
installed!
The cooker is fitted with a safety chain to be fixed by
means of a screw (not supplied with the cooker) to
the wall behind the appliance, at the same height as
the chain is attached to the appliance.
Choose the screw and the screw anchor according
to the type of material of the wall behind the applian-
ce. If the head of the screw has a diameter smaller
than 9mm, a washer should be used. Concrete wall
requires the screw of at least 8mm of diameter, and
60mm of length.
Ensure that the chain is fixed to the rear wall of the
cooker and to the wall, as shown in figure, so that
after installation it is tensioned and parallel to the
ground level.
H5GG1E UA
H5GG5E UA
H5GG5F UA
ENERGY LABEL
and ECODESIGN
Regulation (EU) No 65/2014 supplemen-
ting Directive 2010/30/EU.
Regulation (EU) No 66/2014 implementing
Directive 2009/125/EC.
Standard EN 15181.
Standard EN 30-2-1
Содержание H5GG1E UA
Страница 16: ...16 UA 3 NFC 15 100 50 C i i 8 13 50 C 1500 2 1...
Страница 17: ...17 UA A V i 1 2 2 1 2 7 3 1 2 3 1 2 A 3 V 4 7 1 2 10 MA 3 4 5 MA 1 V 2 7 V I...
Страница 19: ...19 UA 1 2 3 C 1 X 2 3 1 F 15 1 6 1 F X C i i R 24 26 S 16 20 A 10 14 6 4...
Страница 20: ...20 UA A S 140 C MA 250 C 4 5 1 6 1 D 1 1 2 4 3 A S S D 180 C 200 C 200 220 C 1 2...
Страница 22: ...22 UA i i i 1 2 1 i i 2002 96 CE RAEE i i...
Страница 23: ...23 UA i i 1 2 230 25 E 14 3 i S N...