background image

1

GB

To avoid all risk, if the power cable becomes damaged, 
it  must  only  be  replaced  by  the  manufacturer, 
by  an  authorised  service  centre,  or  by  a  qualified 
electrician. 

Adaptation to various types of gas (Fig. 5)

Should the appliance be pre-set for a different type of 
gas than that available, proceed as follows:
•  replace the injectors (Fig. 5) with the corresponding 

type  of  gas  to  be  used  (see  table  “Uses 
characteristics”).

•  to adjust to the minimum, use a screwdriver on the 

screw placed on the tap (Fig. 6) after turning the tap 
to  its  minimum  position.  For  LPG  (butane/propane) 
screw tight

Fig. 6

wok C3 only

Fig. 5

USER CHARACTERISTICS

GAS BURNERS

feed

Burner

ø injeCtorS thermAL CAPACity

tyPe

PreSSure mbar

nominAL

ConSumPtion

norm.

1/100 mm

W

natural gas

G20    20

fast

129

3000

286

l/h

auxiliary

77

1000

95

wok 3

141

3500

333

liquefied gas

G30/G31    28-30/37

fast

87

3000

218

g/h

auxiliary

50

1000

73

wok 3

94

3500

254