Electrical connection (Fig. 4)

 

Prior  to  carrying  out  the  electrical  connection,  please 
ensure that: 
•  the plant characteristics are such as to follow what is 

indicated on the matrix plate placed at the bottom of 
the working area; 

•  that the plant is fitted with an efficient earth connection, 

following the standards and law provisions in force. 
The earth connection is compulsory in terms of the 
law. 

Should  there  be  no  cable  and/or  plug  on  the 
equipment,  use  suitable  absorption  material  for  the 
working temperature as well, as indicated on the matrix 
plate. Under no circumstance must the cable reach a 
temperature above 50°C of the ambient tempera-ture. 
If  connecting  directly  to  the  mains  power  supply, 
fit  a  multi-pole  switch  of  a  suitable  size  for  the  rated 
capacity  with  a  clearance  distance  which  completely 
disconnects the power line under overvoltage category 
III conditions, consistently with the rules of installation 
(the  yellow/green  earth  wir  must  not  be  interrupted). 
The plug or omnipolar switch must be easily reached 
on the installed equipment.

Installation 

This  appliance  is  not  provided  with  a  combu-stion 
product  discharge.  It  is  recommended  that  it  be 
installed in sufficiently aerated places, in terms of the 
laws in force. The quantity of air which is necessary for 
combu-stion must not be below 2.0 m3/h for each kW of 
installed power. See table of burner power. 

 
Positioning (Fig. 2)

The  appliance  can  be  fitted  into  a  working  area 
as  illustrated  on  the  corresponding  figure.  Before 
positioning the hob,  fit the seal 

X

 around the entire 

periphery of the hole cut in the worktop.  

Gas connection (Fig. 3) 

Connect  the  appliance  to  the  gas  cylinder  or  to  the 
installation  according  to  the  prescribed  standards 
in  force,  and  ensure  beforehand,  that  the  appliance 
matches  the  type  of  gas  available.  Otherwise,  see 
“Adaptation  to  various  types  of  gas”.  Furthermore, 
check  that  the  feed  pressure  falls  within  the  values 
described on the table: “User chacteristics”. 
Rigid/semi  rigid  metal  connection  Carry  out  the 
connection with fittings and metal pipes (even flexible 
pipes) so as to obtain counter stress the inner parts of 
the appliance. 

N.B. 

- when the installation has been carried out, check 

the perfect sealing of the entire connection system, by 
using a soapy solution. 