background image

 

                     

Programmable Single Stage Thermostat 

                                       

Reference  No.:

 

HTW-ST01-B 

 

                                                         

 

- 5 -

                                                                            Version 2019-1.0                                                                                             

 

Setting the temperature 

Set the 

SYSTEM 

switch to either 

HEAT 

or 

COOL

, then press the 

 or 

 button until the temperature you want to maintain is 

shown on the right side of the display. If you want to turn the system off, just move the 

SYSTEM 

switch to the 

OFF 

position and the 

FAN 

switch to the 

AUTO 

position. 

 Clock setting 

Press the 

TIME 

button to enter into clock/week setting, press ▲ or ▼ buttons to adjust respective values.   

Hour-Minute-Week 

Please adjust the hour correctly that associate with actual AM/PM.   

Filter review 

Move the 

SYSTEM

 switch to the 

HEAT

 or 

COOL

 position, then press and hold the 

 and 

buttons for 5 seconds to review filter 

running days. To exit the review menu press the 

 or 

 buttons one time. Or If no buttons are pressed within 15 seconds, the 

thermostat will exit the configuration menu.   

In review mode, press and hold the ▲

 

and ▼

 

15 sec. to clean the filter warning. It will show “dEF” blink. 

Child Lock 

Quickly and simultaneously press the

  and 

  three times to lock the temperature adjustment, and again to unlock. 

RESET function. 

This function can help operator to recovery system when fault happened, display out of order or system halted. Please use a pin 

to insert in button RESET hole till sounded click, then loosen it.   

Hold Temperature 

With the 

SYSTEM 

switch set to 

HEAT 

or 

COOL

, momentarily press the 

HOLD 

button. 

HOLD 

will be displayed. Use 

the 

 or 

 buttons to adjust the temperature. The thermostat will control the room temperature at the selected setting 

until you press the 

RUN 

button to restart the program operation. 

Temperature Override 

(When in the program 

RUN

 mode)

Press the 

 or 

 buttons to select the desired room temperature. The thermostat will override the current programming and keep the 

Room temperature at the selected temperature until the next program period begins. The thermostat will then revert back to the 

program temperatures. 

 

Move the 

SYSTEM 

switch to the 

OFF 

position, then press and hold the 

PRGM 

and 

RUN 

buttons for 3 seconds to enter the 

configuration menu. The display will show the first item in the configuration menu. Use the ▲or▼ buttons to adjust respective 

values.Press the 

PRGM 

=next menu item, press 

TIME 

= previous menu item.   

All settings will revert to factory default values by press the 

RESET 

hole

 

button, including program settings. 

To exit the configuration menu and return to normal operation, press the 

RUN 

button.   

If no buttons are pressed within 130 seconds, the thermostat will exit the configuration menu automatically. 

The configuration menu chart summaries the configuration options. An explanation of each option follows. 

Step 

Press Buttons 

Displayed (Defaults) 

Select by ▲ or▼   

Description 

PRGM 

and 

RUN

 

3 seconds 

CC (FA) 

FA or SL 

Select (FA)st or (SL)ow 
cooling cycles,   
Default = FA

-Note 1

 

PRGM

 

HC (FA) 

FA or SL 

Select F(ast) or (S)low Heating 
cycles. Default = FA

-Note 1

 

Thermostat Operation 

Configuration Menu 

The  configuration  menu  allows  you  to  set  certain  thermostat  operating  characteristics  to  your  system  or  personal 

requirements. It is also called as ISU(Installation Set-Up) process. 

Содержание HTW-ST01-B

Страница 1: ...power loss No batteries are required Apply to 24VAC or 2 AA alkaline batteries power supply Air Filter change Indicator Low Battery Indicator Temperature calibration 4 or 5 wire compatible C is optio...

Страница 2: ...r screwdriver carefully unscrew one wire at a time from the terminal block and attach the corresponding wire label sticker Please note that not all terminals may be used and that there s no standard c...

Страница 3: ...ase from your wall Mounting and Wiring Your New Thermostat 1 Install new thermostat base 2 Connect wires to corresponding terminal blocks Match each labeled wire to it s corresponding terminal on the...

Страница 4: ...ition If the heating system has a standing pilot be sure to light it Press to adjust thermostat setting room temperature The heating system should begin to operate Press to adjust temperature setting...

Страница 5: ...st the temperature The thermostat will control the room temperature at the selected setting until you press the RUN button to restart the program operation Temperature Override When in the program RUN...

Страница 6: ...stem at a 0 5 F 0 5 C differential and SL cycles the system at 1 5 F 1 5 C 2 When operated from batteries only the LCD display backlight will be illuminated less than 5 seconds after each button press...

Страница 7: ...to be cooler warmer when the building is vacant or during periods of low activity During early morning hours the need for cooling is usually minimal The time of day clock must be set correctly in orde...

Страница 8: ...d start time and temperature for RETURN 3 Period and SLEEP 4 Period Press PRGM again and SAT SUN indicating weekend programming parameters setting Repeat step 5 to complete Saturday and Sunday program...

Отзывы: