10
P6 Smart Charger
33
mAh
24.08
V
Charging...
CH1
00:00:33
4.014V
4.014V
1
4
4.010V
4.023V
2
5
4.010V
4.015V
3
6
5.0
W
121
A
LiPo-6S(4.20V) 73%
2
Operation and Setup
Working parameters Display
Charging
Operation
Time
Capacity
charged
Task Status
Output
Current
Total Battery
Voltage
Cell Voltage
Current channel
Charging Status : Simple Operation
1. Connect power supply to the charger, wait for
the system to complete its self-checking.
Connect the battery to the charger in the standby interface;
2. After selecting the corresponding channel, short press the speed shuttle key to pop up
the "Task Settings" menu, set the task to "Charge" ; adjust the task parameters, and short
press the speed shuttle key to start the task;
Scroll t
he speed shuttle key can switch the display information in the lower half of the screen, which are cell voltage, cell
internal resistance and the operating data. Cell voltage can only be displayed in the mode of balance charging and the
internal resistance can only be displayed while measurement is valid ( not in precharged status and none of the cells
reaches fully charged status within 2 minutes);
3.
W
hen the charge task is executing, short p
ress the speed shuttle key can pop up the "Ad
just
Task” m
enu to adjust the charge current ; long press the
CH k
ey can stop the current task ;
4. Enjo
y.
Battery parameters and
Percentage of completion
Output
Power
Содержание P6